background image

  

BURLEY G4240 – 49 MODEL 

FLUELESS GAS HEATER 

 

INSTALLATION, SERVICING 

& USER INSTRUCTIONS 

 

FOR USE IN THE COUNTRIES STATED ON THE DATA PLATE AND CARTON 

WITH NATURAL GAS G20 

OR LPG PROPANE GAS G31 

(REFER TO RATING LABEL) 

 

For the following countries: GB, IE 

 

EVEN IF YOU HAVE FITTED THESE FIRES BEFORE,  

PLEASE FOLLOW THESE INSTRUCTIONS STEP BY STEP. 

Legislation and regulations do change over time! 

 

LEAVE THESE INSTRUCTIONS WITH THE USER

 

 
 
 
 
 
 
 
 
 
 

Burley Appliances Ltd

,  

Lands End Way, Oakham, Rutland, LE15 6RB 
Telephone: +44 (0)1572 756956 Fax: +44 (0)1572 724390                           
e-mail: 

[email protected]

     web: 

www.burley.co.uk

  

G4240InstUser 

G20/31 

Issue Sept08 – v.4 

TO OBTAIN YOUR FIRST YEAR GUARANTEE, THE INSTALLER AND CUSTOMER  

MUST FILL IN THE SEPARATE GUARANTEE AND RETURN IT TO  

BURLEY WITIHIN 7 DAYS OF FITTING. 

A FREE SECOND YEAR GUARANTEE IS OFFERED SUBJECT TO THE FIRE BEING SERVICED 

BY A CORGI ENGINEER DURING THE FIRST YEAR OF OWNERSHIP. 

PROOF OF SERVICING MUST BE RETAINED 

FAILURE TO HAVE THIS APPLIANCE FITTED BY A CORGI REGISTERED 

 FITTER INVALIDATES THE WARRANTY  

Содержание G4240

Страница 1: ...H THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4240InstUser G20 31 Issue Sept08 v...

Страница 2: ...n Injector manual valve Elbow 92 300 Elbow 92 90 Injector remote Elbow 92 170 Elbow 92 85 The inlet pressure must be within 1mBar of specification with all gas appliances in the house switched on and...

Страница 3: ...tre m divide the room volume in cubic feet by 35 3 3 7 The heater must not be installed in high rise blocks of flats unless a gas supply already exists bed sitting rooms basements which are not open o...

Страница 4: ...xtra part no SPACERKIT and can stand directly against a wall Care should be taken with wall coverings as it may discolour them over time 4 3 The fire comes with a 60mm spacer fitted to the front trim...

Страница 5: ...the pull from the cavity causing heat build up on the fire surround back panel or moisture ingress from the cavity 4 12 Any under grate draught devices must be sealed off 4 13 If using the fire in a...

Страница 6: ...pushing gas pipes through walls seal the pipe ends to prevent debris entering the pipes 6 4 Drill and fit cable fixing positions in accordance with diagram or alternatively drill and fit screws throu...

Страница 7: ...rect coal is fitted in the correct place There must be a clear gap between the two sets of coals Always replace the glass after laying the coals Do not attempt to use the unit with broken damaged glas...

Страница 8: ...there is a pressure of 20mb 1mb for natural gas appliances or 37mb for propane appliances Now turn on every other gas appliance in the house and re check the pressure The pressure must still be within...

Страница 9: ...remove all debris around the pilot light The logs and backing brickwork contain refractory fibre RCF Excessive exposure to these materials may cause temporary irritation to the eyes skin and respirato...

Страница 10: ...7927 first zero the equipment and sample the entire width of the combustion product outlet Ratio of CO CO2 should be less than 0 002 within 30 minutes 20ppm CO per 1 CO2 A reading of CO in the room ce...

Страница 11: ...e made battery housing Note If the fire emits a beeping sound this is just the safety system priming itself Because the remote control uses battery power when in the stand by mode The battery will nee...

Страница 12: ...sensor into a clearer position In the event of the fire not working check both of the above points before calling an engineer 5 To ignite the fire point the handset at the fire push and hold simultane...

Страница 13: ...the test must be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least...

Страница 14: ...e consult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air...

Страница 15: ...nstaller Tolerances It is important to take a gas rate test over a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more cr...

Страница 16: ...hin the first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other than a CORGI fi...