11
Setting the minimum burn rate
As with all wood burners, the Icarus should not be fully shut down and
allowed to smoulder, doing so creates smoke and coats the inside of
the flue and stove with creosote. The ideal minimum setting should
ensure the stove burns with a constant lazy flame, if the fire dies and
relights with a pulsing flame or appears to burn above the fuel then the
minimum air setting is too low.
There is a hole to the right of the air control knob with a screw behind.
This screw adjusts the range of movement of the control knob for the
low rate air supply. If the fire burns too vigorously when the control knob
is pulled all the way out, use a No 2 Phillips screwdriver to turn the
screw anti clockwise, this will let you pull the knob out a little further. If
the flame is not maintaining a constant lazy flame, turn the screw
clockwise.
Lighting and operating the stove
Always use the glove provided as all surfaces will get very hot.
Children, pets or adults who may be at risk must always be supervised
and not left with the stove. An approved fireguard must always be fitted.
The ICARUS 5 has been designed to be easy to light and operates very
efficiently with minimum input from the operator. Please follow these
instructions.
Please note on the first time of lighting the stove there will be an odour
and there may be a haze or smoke from the curing paint. This is
completely normal and it is recommended that you ventilate the room
during this process. The paint will finish curing if the stove is run at the
Содержание 9605