background image

853134-0405H

Report#: 0215WS054S

WONDERWOOD

United States Stove Company

227 Industrial Park Road

P.O. Box 151

South Pittsburg, TN 37380

Owner’s Operation and Instruction Manual

SAFETY NOTICE:

If this heater is not properly installed, a house fire 

may result.  For your safety, follow the installation 

instructions. Never use make shift compromises 

during the installation of this heater. Contact local 

building or fire officials about permits, restrictions 

and installation requirements in your area.

CAUTION!

Please read this entire manual before you 

install or use your new room heater. Failure 

to follow instructions may result in property 

damage, bodily injury, or even death. 

Improper Installation Could Void Your 

Warranty!

SAVE THESE INSTRUCTIONS

THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU 

TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.

MODEL: B2941E(B)

Certified to: UL 1482-11 (R2015) and 

Certified to: ULC-S627-00 

Not approved for use in mobile homes, do not 

install in a mobile home

U.S. Environmental Protection Agency 

Certified to comply with 2015 particulate 

emissions standards.

CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon monoxide, which 

is know to the State of California to cause cancer, birth defects and/or other 

reproductive harm. For more information, go to www.P65warnings.ca.gov

Ce produit peut vous exposer à des produits chimiques, y compris le 

monoxyde de carbone, qui est connu dans l'État de Californie pour causer 

le cancer, des malformations congénitales et / ou d'autres problèmes de 

reproduction. Pour plus d'informations, visitez www.P65warnings.ca.gov

Содержание WONDERWOOD

Страница 1: ...IS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLE YOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE MODEL B2941E B Certified to UL 1...

Страница 2: ...ised BTU s are based on the first hour of operation at high burn rate burning cordwood CAUTIONS Hot while in operation Keep children clothing and furniture away Contact may cause skin burns Do not use...

Страница 3: ...meter Black Steel pipe 24 gauge minimum and elbow s either adjustable1 or corrugated as necessary 1 2 Sheet Metal Screws 6 Inside Diameter Underwriters Laboratories UL listed Residential Type and Buil...

Страница 4: ...t door knob is mounted on the inside of the cabinet door to facilitate shipping and must be removed and re installed for proper usage To get the cabinet door open place your hand under the cabinet fra...

Страница 5: ...air distribution from the stove may be facilitated by the installation of a blower The wood stove must not be hooked up to a hot air distribution system since an excessive accumulation of heat may occ...

Страница 6: ...rough a wall or partition of combustible construction is desired the installation must conform to CAN CSA B365 A flue pipe crossing a combustible wall must have a minimum clearance of 18 457 2mm To re...

Страница 7: ...h removal opening If there is a horizontal section of chimney connector the floor protector should go under it and 2 inches beyond each side The floor protector should exceed the stove as follows 8 20...

Страница 8: ...pipe should never exceed 8 to 10 2 4m to 3 04 m Except for cases of vertical installation cathedral roof style where the smoke exhaust system can be much longer and connected without problem to the ch...

Страница 9: ...imney fires Note that it is the chimney and not the stove which creates the draft effect your stove s performance is directly dependent on an adequate draft from your chimney The following recommendat...

Страница 10: ...ame manufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance to...

Страница 11: ...ociation NFPA by having it inspected by a professional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed an...

Страница 12: ...mney connector and a minimum 24 gage ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing f...

Страница 13: ...the forest floor should be considered wet and requires full seasoning time Standing dead wood can usually be considered to be about 2 3 seasoned Splitting and stacking wood before it is stored accele...

Страница 14: ...lose the door If ignition of the piece is accomplished within 90 seconds from the time if was placed in the stove your wood is correctly dried If ignition takes longer your wood is damp If your wood h...

Страница 15: ...brick Wood should be 3 to 4 below top of firebrick A burned out heat chamber may result Do not use artificial or wax logs Build fire on the floor of the stove Do not use additional grates or andirons...

Страница 16: ...Timer SAT is used to control the duration of secondary air entering the stove When burning the stove be sure the timer is set to open Timer Knob past One Hour and Timer Lever to HI The SAT is only use...

Страница 17: ...r the thermostat closes CAUTION Do not operate this heater with the loading door open Continuous operation with a door open will over heat the unit This heater is designed for Thermostatic and Burn Ra...

Страница 18: ...given settings Visible smoke consist of unburned fuel and moisture leaving your stove Learn to adjust the air settings of your specific unit to produce the smallest amount of visible smoke Wood that h...

Страница 19: ...the stove every time it is emptied in order to insure that no parts have been damaged in which case repairs must be performed immediately Inspect and clean the chimney and connector pipe periodically...

Страница 20: ...20 1 2 3 9 8 7 6 5 4 12 11 10 42 41 28 13 14 17 15 16 17 20 19 23 22 24 25 26 27 29 30 31 32 33 37 38 34 35 36 40 39 21 43 44 Repair Parts...

Страница 21: ...Assy Cabinet Door 1 16 89635 Knob Door 1 17 610837 Assy Cabinet Door Frame 1 18 83093 Latch Stove Spring 1 19 3070019 Jack Chain 1 20 67743 Assembly Thermostat 1 21 27291 Front Liner Top 1 22 610838...

Страница 22: ...Door Hinge 1 6 88032 1 Rope Fiber 41 7 40764 Cast Door 1 8 27460 Ash Door Hinge 1 9 88032 1 Rope Fiber 27 5 8 9 6 3 2 1 7 4 In order to maintain warranty components must be replaced using original man...

Страница 23: ...72 Brick Spacers 2 5 27564 Floor Back 1 6 610221 Floor Welded 1 7 610223 Cleanout Cover Weldment 1 1 2 3 4 6 5 7 In order to maintain warranty components must be replaced using original manufacturers...

Страница 24: ...terruptions or uctuations of electrical power supply to the appliance Non USSC venting components hearth components or other accessories used in conjunction with the appliance USSC s obligation under...

Страница 25: ...7 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _________________...

Страница 26: ...ence future Lors de l criture toujours donner le num ro de mod le complet qui se trouve sur la plaque signal tique fix e sur l appareil de chauffage Lors de la commande des pi ces de rechange fournir...

Страница 27: ...____________________ Company__________________________________________ N de t l phone ___________________________________ Po le Inspect Chemin e Swept Articles Remplac ________________________________...

Страница 28: ...t autoris es et approuv es par crit par USSC et ou 9 les interruptions ou uctuations de l alimentation lectrique de l appareil Composants d vacuation des gaz composants de l tre ou accessoires utilis...

Страница 29: ...Spacers Brick 2 5 27564 Etage Retour 1 6 610221 Etage soud 1 7 610223 Cleanout Cover Weldment 1 1 2 3 4 6 5 7 Afin de maintenir la garantie les composants doivent tre remplac s par des pi ces d origin...

Страница 30: ...abricant de l appareil L utilisation de composants tiers annule la garantie Pi ces De Rechange L gende N de pi ce Description Qt 1 892767 Bouton en bois 2 2 27486 Poign e de porte 2 3 27462 Catch port...

Страница 31: ...rte Cabinet 1 16 89635 Knob Porte 1 17 610837 Assy Cadre porte Cabinet 1 18 83093 Loquet Cuisini re Spring 1 19 3070019 Jack Chain 1 20 67743 Assembl e Thermostat 1 21 27291 Avant Liner Top 1 22 61083...

Страница 32: ...21 Pi ces De Rechange 1 2 3 9 8 7 6 5 4 12 11 10 42 41 28 13 14 17 15 16 17 20 19 23 22 24 25 26 27 29 30 31 32 33 37 38 34 35 36 40 39 21 43 44...

Страница 33: ...t nettoyer le tuyau de la chemin e et le connecteur p riodiquement pour l accumulation de cr osote ou obstructions GASKETING La porte ce cette unit utilise un joint de corde de 1po de diam tre Il est...

Страница 34: ...fonctionnement appropri es La combustion secondaire ne peut avoir lieu que si le foyer est assez chaud V rifiez toujours l tat de cr osote une fois tous les deux mois et ont ramoner votre chemin e au...

Страница 35: ...s po les bois l humidit dans le bois br l quitte le po le sous forme de vapeur Le pouvoir calorifique sup rieur c est lorsque l eau quitte le processus de combustion sous forme enti rement condens e D...

Страница 36: ...LA CHAMBRE SI L AIR FROIDE FONCTIONNE LE JOURNAUX 5 Allumez le feu et fermez la porte de chargement 6 Attendez 3 5 minutes puis ajoutez du bois de chauffage assaisonn Voir la section concernant le car...

Страница 37: ...e en position ouverte et verrouill e avec le levier d arr t de la minuterie est r gl e sur Salut et votre po le br lera de mani re optimale Il ne faut pas utiliser la minuterie sauf si vous souhaitez...

Страница 38: ...ON br lez non trait seulement Bois contenant un conservateur des feuilles m talliques du charbon du plastique des ordures de soufre ou de l huile est dangereux pour l environnement et endommager l app...

Страница 39: ...n air ouverte en tirant dessus et fermer la porte Si l allumage de la pi ce est r alis e dans les 90 secondes partir du moment qu il eut t plac dans le po le votre bois est bien s ch Si l allumage pre...

Страница 40: ...s mat riaux peut causer des manations de fum es toxiques ou rendre le chauffage inefficace en raison de la fum e Le bois mort tomb des arbres doit tre consid r comme tant mouill et doit donc tre s ch...

Страница 41: ...ible Commencez avec une partie de chemin e Solid Pak fabriqu e en usine agr e d au moins 12 304 mm de diam tre int rieur avec une isolation de 1 25 4 mm ou plus et un raccord de chemin e de 8 de diam...

Страница 42: ...NERIE Assurez vous qu une chemin e en ma onnerie r ponde aux standards minimum de l Association nationale de protection contre les incendies NFPA en la faisant inspecter par un professionnel Assurez v...

Страница 43: ...INE Lorsqu une chemin e m tallique pr fabriqu e est utilis e les instructions d installation du fabriquant doivent tre respect es Vous devez galement acheter aupr s du m me fabriquant et installer l e...

Страница 44: ...effet de tirage les performances de votre po le d pendent directement du bon tirage de votre chemin e Les recommandations suivantes peuvent tre utiles pour l installation de votre chemin e 1 Ne conne...

Страница 45: ...le de tuyau de chemin e doit tre conforme NFPA 211 Vous pouvez contacter la NFPA Association nationale de protection contre les incendies et demander la derni re dition du standard 211 de la NFPA Pour...

Страница 46: ...de dessus PLANCHER PROTECTEUR Lorsque le chauffage est utilis sur un plancher combustible utiliser un protecteur Underwriters Liste de plancher qui est conforme aux normes UL UL 1618 et CAN ULC pour...

Страница 47: ...ie de construction combustible est souhait e l installation doit tre conforme la norme CAN CSA B365 Un tuyau de raccordement traversant un mur combustible doit avoir un d gagement minimum de 18 457 2...

Страница 48: ...le bois fonctionne aussi par convection qui est par le d placement de l air chaud vers le haut et son remplacement avec refroidisseur d air Si n cessaire la distribution d air chaud du po le peut tre...

Страница 49: ...a vis de la machine et la poign e de porte 2 Placez le bouton sur l ext rieur de la porte de l armoire r installez la vis de la machine et serrer en faisant attention de ne pas d pouiller les fils dan...

Страница 50: ...pe Diam tre noir en acier minimum de calibre 24 et le coude s soit adjustable1 ou ondul n cessaire Vis de 1 2 de t lerie 6 Diam tre int rieur Underwriters Laboratories UL num r s type r sidentiel et a...

Страница 51: ...seront reconnaissants Les instructions concernant l installation de votre po le bois se conformer la norme UL 1482 11 R2015 et les normes ULC S627 00 Ce manuel d crit l installation et le fonctionnem...

Страница 52: ...NCE S il vous pla t lire l int gralit de ce manuel avant d installer ou d utiliser votre nouvel appareil de chauffage Le non respect des instructions peut entra ner des dommages mat riels des blessure...

Отзывы: