14
SECTION: J - Failures:
J-1) Failure table:
WARNING
Observe the general safety precautions before install, maintenance and repair.
Problem
Possible Cause
Possible Solution
Checkpoints
Leakage along the shaft
Running surfaces of the
mechanical seal worn or damaged
Replace the mechanical seal
Check the pump for dirt-abrasive
parts
New pump: seal stuck due to
assembly
Open and close the outlet shut-off
valve quickly during operation
Mechanical seal mounted
incorrectly
Install the mechanical seal
correctly. Use water and soap as
a lubricant
Elastomers affected by medium
Use the right rubber compound for
the mechanical seal
Pressure too high
Use the right type of mechanical
seal
Shaft worn
Replace shaft and mechanical seal
Pump has been operating without
water
Replace the mechanical seal
Leakage along the
shroud at the top bracket
or at the pump foot
O-ring worn
Replace the O-ring
O-ring not resistant to the medium
to be pumped
Replace O-ring by an O-ring with
better resistance
Too much tension on the pump
foot; it becomes oval
Decrease tension on piping
Mount the pump foot tensionless
Support the connections
Pump is vibrating or noisy Coupling mounted incorrectly
Install the coupling in parallel
Faulty settling of the hydraulic
assembly
Adjust the assembly according to
the manual
There is no water in the pump
Fill and vent the pump
No supply
Make sure there is suf
fi
cient
supply. Check for blockages in the
supply line
Bearings of pump and/or motor
worn
Have the bearings replaced by a
certi
fi
ed company
Available NPSH too low
(cavitation)
Improve suction condition
Pump does not operate in its
working range
Select another pump or adjust the
system to work within its working
range
Pump is standing on an uneven
surface
Level the surface
Malfunction
Internal blockage in the pump
Have the pump inspected by a
certi
fi
ed company
Pump does not start
No voltage on the terminal clamps Check the power supply
• Circuit
• Main
Switch
• Fuses
Check the motor safety relay
• Earth leakage switch
• Protective
relay
Thermal motor safety switch
triggered
Reset the thermal motor-safety.
Contact the supplier, if this
problem occurs more often.
The motor is running, but
the pump does not work
The motor shaft has been broken
Contact the supplier
The pump shaft has been broken
Contact the supplier
The coupling between pump and
motor shaft is loose
Tighten the connecting screws to
the recommended torque
Содержание BPLHS Series
Страница 22: ...22 Selection O ring and shroud BPV S F V 10 18 Selection O ring and shroud BPV S 2 4...
Страница 32: ...32 SECTION S Sectional Drawings S 1 Sectional drawing BPV S C F 2 4 10 18...
Страница 33: ...33 S 2 Sectional drawing BPV S C F 32 10 32 20...
Страница 34: ...34 S 3 Sectional drawing BPV S C F 32 30 32 40 32 50 32 60 32 70 32 80 32 90 with cartridge seal...
Страница 35: ...35 S 4 Sectional drawing BPV S C F 45 10...
Страница 36: ...36 S 5 Sectional drawing BPV S C F 45 20 45 30 45 40 45 50 45 60 with cartridge seal...
Страница 37: ...37 S 6 Sectional drawing BPV S C F 65...
Страница 38: ...38 S 7 Sectional drawing BPV S C F 85...
Страница 39: ...39 S 8 Sectional drawing BPVLHS 6...
Страница 40: ...40 SECTION T Exploded Views T 1 Exploded View BPV S 2 4 10 18...
Страница 41: ...41 T 3 Exploded View BPV S F 32 45...
Страница 42: ...42 T 4 Exploded View BPV S F 32 45 with cartridge seal...
Страница 43: ...43 T 5 Exploded View BPV S F 65...
Страница 44: ...44 T 7 Exploded View BPLHS 6...
Страница 54: ...Notes...