Burk Plus-X RP-8 Скачать руководство пользователя страница 8

Plus-X RP-8 Adapter Installation and Operation Manual Rev B 

 

Uploading New Firmware 

You can load new firmware to the Plus-X RP-8 Adapter using its onboard web interface. Navigate to the 
IP address of the Plus-X RP-8 Adapter, log on and click the 

Upload Firmware

 link. Click the 

Browse

 

button to select the firmware file, then click 

Upload

 to load the new firmware. The Plus-X RP-8 Adapter 

will reboot after the firmware upload is complete. 

 

For the latest firmware updates, visit www.burk.com.

 

Troubleshooting 

If the network connection between the Plus-X RP-8 Adapter and ARC Plus is lost, the ARC Plus will log 
an alarm after three minutes of network failure. The Plus-X RP-8 Adapter Link LED will also turn off. 
Check your network settings on both the ARC Plus and Plus-X RP-8 Adapter. 

Note: Plus-X RP-8 Adapter events and errors are logged to the ARC Plus event list, which is accessible by 
the ARC Plus front panel and from AutoPilot. 

Getting Help 

For customer support, please email [email protected] or call our direct customer support line at 978-
486-3711. We will be glad to assist you. The customer support office is open Monday – Friday, 9AM to 
5PM Eastern time. 

Warranty 

Burk Technology, Inc. warrants the Plus-X RP-8 Adapter to be free of defects in materials and 
workmanship for a period of 24 months from the date of purchase. Equipment will be repaired or 
replaced at the option of Burk Technology and returned freight prepaid to the customer. Damage due 
to abuse or improper operation or installation of the equipment or caused by fire or flood or harsh 
environment is not to be covered by this warranty. Damage in shipping is not the responsibility of Burk 
Technology. A return authorization must be obtained before returning any equipment. Materials 
returned under this warranty must be shipped freight prepaid and insured in the original shipping 
carton or suitable substitute to Burk Technology, Inc., 7 Beaver Brook Road, Littleton, MA 01460. 
Repairs not covered under this warranty will be made at prevailing shop rates established by Burk 
Technology. 

THE WARRANTY SET FORTH ABOVE IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE. BURK TECHNOLOGY, INC. SHALL NOT BE LIABLE TO ANY 
PARTY FOR ANY INCIDENTAL, SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES ARISING FROM 
THE USE OF THIS EQUIPMENT. 

Содержание Plus-X RP-8

Страница 1: ...Plus X RP 8 Adapter Installation and Operation Manual ...

Страница 2: ...ble of Contents Introduction 1 Compatibility 1 Unpacking 2 Front Panel Indicators 3 Hardware Configuration 3 Installation 4 Software Configuration 4 Uploading New Firmware 6 Troubleshooting 6 Getting Help 6 Warranty 6 Appendix A Specifications 7 ...

Страница 3: ...s alarm monitoring and telephone control will be unavailable for the Plus X device Before you Begin Before installing the Plus X RP 8 Adapter please have the following network settings ready A static IP address for the Plus X RP 8 Adapter The IP address of your ARC Plus The subnet mask and gateway address for your LAN Compatibility Before installing the Plus X RP 8 Adapter please verify that the A...

Страница 4: ...Plus X RP 8 Adapter Installation and Operation Manual Rev B 2 Unpacking The Plus X RP 8 Adapter ships with the following Plus X RP 8 Adapter unit Power cord 10 shielded CAT5 cable ...

Страница 5: ...e Configuration The Plus X RP 8 Adapter is configured via its onboard web interface Open a web browser and navigate to 192 168 0 100 The web page will prompt you for a username and password Enter the username admin and password password Note The default IP address is 192 168 0 100 and the default password is password If either of these values has been changed and you do not know what they are you ...

Страница 6: ...figuration Now that the Plus X RP 8 Adapter is installed on the network you are ready to add the unit to the ARC Plus using AutoLoad Plus AutoLoad Plus is included with the ARC Plus and may also be downloaded from www burk com Configuration involves Adding the Plus X RP 8 Adapter unit to the ARC Plus Mapping Plus X RP 8 Adapter channels to unused ARC Plus channels Importing settings from your ARC ...

Страница 7: ...appearance and labeling only Manually Mapping Plus X RP 8 Adapter Channels Overriding channels in AutoLoad Plus If desired you may manually map Plus X RP 8 Adapter channels to ARC Plus channels in AutoLoad Plus by selecting the Meter Channels Status Channels or Commands tab as appropriate 1 Within any of these tabs click the Source button to configure a channel to use a Plus X device channel as it...

Страница 8: ...er support office is open Monday Friday 9AM to 5PM Eastern time Warranty Burk Technology Inc warrants the Plus X RP 8 Adapter to be free of defects in materials and workmanship for a period of 24 months from the date of purchase Equipment will be repaired or replaced at the option of Burk Technology and returned freight prepaid to the customer Damage due to abuse or improper operation or installat...

Страница 9: ...equirements 100 to 240VAC 47 60Hz 0 15A power cube supplied Connectivity RJ 45 for cat 5 ethernet connection to ARC Plus 2x8 header 0 1 spacing mates with existing ribbon cable from RP 8s Channel Capacity 8 metering or status and 8 command channels with raise and lower per PR 8 up to 8 RP 8s Metering Input Range 4 5VDC to 4 5VDC Metering Input Accuracy 99 75 accuracy full scale ...

Отзывы: