Plus-X RP-8 Adapter Installation and Operation Manual Rev B 

 

Introduction 

The Plus-X RP-8 Adapter connects directly to Sine Systems RP-8 Interface Panels to allow a fast, easy 
upgrade to the ARC Plus Remote Control. The Plus-X RP-8 Adapter communicates with the ARC Plus 
via LAN/WAN, allowing installation anywhere a network connection is available. 

The Plus-X RP-8 Adapter is part of the Plus-X family of Ethernet I/O products designed for the ARC Plus. 

Installation Note 

Even though you may operate the ARC Plus and Plus-X RP-8 Adapter on different subnets, Burk 
Technology strongly recommends installing the Plus-X RP-8 Adapter on the same LAN as the ARC Plus. 
In a network failure, an ARC Plus can only continue to monitor and control a Plus-X device on the same 
LAN. If the network link between the units is not available, ARC Plus macros, alarm monitoring and 
telephone control will be unavailable for the Plus-X device. 

Before you Begin 

Before installing the Plus-X RP-8 Adapter, please have the following network settings ready: 

 

A static IP address for the Plus-X RP-8 Adapter 

 

The IP address of your ARC Plus 

 

The subnet mask and gateway address for your LAN 

Compatibility 

Before installing the Plus-X RP-8 Adapter , please verify that the ARC Plus firmware, AutoPilot software 
and AutoLoad Plus software versions are current. Updates are available at 

www.burk.com

.  The 

following are minimum software and firmware requirements 

Software  

Version 

ARC Plus firmware 

2.1.0, 2.3.0 recommended 

 

AutoLoad Plus software* 

2.0.0, 3.1.0 recommended

 

AutoPilot® 2010 software 

2.5.0, 2.9.16 recommended 

 

 

*

 

Please download the current Plus-X RP-8 Adapter AutoLoad definition XML file from 

www.burk.com

”Installing Plus-X Definition Files” can also be downloaded from 

www.burk.com

 

The onboard web interface is compatible with Internet Explorer version 8 or newer, Firefox, Chrome, 
and other modern web browsers. 

Содержание Plus-X RP-8

Страница 1: ...Plus X RP 8 Adapter Installation and Operation Manual ...

Страница 2: ...ble of Contents Introduction 1 Compatibility 1 Unpacking 2 Front Panel Indicators 3 Hardware Configuration 3 Installation 4 Software Configuration 4 Uploading New Firmware 6 Troubleshooting 6 Getting Help 6 Warranty 6 Appendix A Specifications 7 ...

Страница 3: ...s alarm monitoring and telephone control will be unavailable for the Plus X device Before you Begin Before installing the Plus X RP 8 Adapter please have the following network settings ready A static IP address for the Plus X RP 8 Adapter The IP address of your ARC Plus The subnet mask and gateway address for your LAN Compatibility Before installing the Plus X RP 8 Adapter please verify that the A...

Страница 4: ...Plus X RP 8 Adapter Installation and Operation Manual Rev B 2 Unpacking The Plus X RP 8 Adapter ships with the following Plus X RP 8 Adapter unit Power cord 10 shielded CAT5 cable ...

Страница 5: ...e Configuration The Plus X RP 8 Adapter is configured via its onboard web interface Open a web browser and navigate to 192 168 0 100 The web page will prompt you for a username and password Enter the username admin and password password Note The default IP address is 192 168 0 100 and the default password is password If either of these values has been changed and you do not know what they are you ...

Страница 6: ...figuration Now that the Plus X RP 8 Adapter is installed on the network you are ready to add the unit to the ARC Plus using AutoLoad Plus AutoLoad Plus is included with the ARC Plus and may also be downloaded from www burk com Configuration involves Adding the Plus X RP 8 Adapter unit to the ARC Plus Mapping Plus X RP 8 Adapter channels to unused ARC Plus channels Importing settings from your ARC ...

Страница 7: ...appearance and labeling only Manually Mapping Plus X RP 8 Adapter Channels Overriding channels in AutoLoad Plus If desired you may manually map Plus X RP 8 Adapter channels to ARC Plus channels in AutoLoad Plus by selecting the Meter Channels Status Channels or Commands tab as appropriate 1 Within any of these tabs click the Source button to configure a channel to use a Plus X device channel as it...

Страница 8: ...er support office is open Monday Friday 9AM to 5PM Eastern time Warranty Burk Technology Inc warrants the Plus X RP 8 Adapter to be free of defects in materials and workmanship for a period of 24 months from the date of purchase Equipment will be repaired or replaced at the option of Burk Technology and returned freight prepaid to the customer Damage due to abuse or improper operation or installat...

Страница 9: ...equirements 100 to 240VAC 47 60Hz 0 15A power cube supplied Connectivity RJ 45 for cat 5 ethernet connection to ARC Plus 2x8 header 0 1 spacing mates with existing ribbon cable from RP 8s Channel Capacity 8 metering or status and 8 command channels with raise and lower per PR 8 up to 8 RP 8s Metering Input Range 4 5VDC to 4 5VDC Metering Input Accuracy 99 75 accuracy full scale ...

Отзывы: