Plus-X 600 

Installation and Operation Manual 

Содержание Plus-X 600

Страница 1: ...Plus X 600 Installation and Operation Manual ...

Страница 2: ...ble of Contents Introduction 1 Compatibility 1 Unpacking 2 Front Panel Indicators 2 Hardware Configuration 2 Installation 4 Software Configuration 5 Uploading New Firmware 7 Troubleshooting 8 Getting Help 8 Warranty 8 Appendix A Specifications 9 ...

Страница 3: ...oring and telephone control will be unavailable for the Plus X device Before you Begin Before installing the Plus X 600 please have the following network settings ready A static IP address for the Plus X 600 The IP address of your ARC Plus The subnet mask and gateway address for your LAN Compatibility Before installing the Plus X 600 please verify that the ARC Plus firmware AutoPilot 2010 software...

Страница 4: ...ff No connection to ARC Plus Link LED Flashing Green Red Maintenance Mode Link LED Flashing Red No connection to ARC Plus unit is in maintenance mode Hardware Configuration The Plus X 600 is configured via its onboard web interface Open a web browser and navigate to 192 168 0 100 The web page will prompt you for a username and password Enter the username admin and password password Note The defaul...

Страница 5: ...HTTP and Plus X ports of the Plus X 600 The default settings are recommended Burk Technology recommends changing the Plus X 600 password The password is used to log on to the onboard web interface To change the password check the Change Password box and enter the new password in the Password and Confirm fields When you are finished click Save Note If you are unsure what network settings to use con...

Страница 6: ...elay Pairing The Plus X 600 includes 12 relays Relays may be used individually or in raise lower pairs for up to 6 pairs Use the onboard web interface to configure relay pairing Log on to the web interface select Settings from the menu then Relay Pairs from the list on the left hand side Follow the onscreen instructions to continue Paired Relay Example Plus X 600 relay 1 is paired with relay 7 and...

Страница 7: ...luded Pins for common normally open and normally closed are indicated for each relay 1 2 3 4 5 6 C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC C NO NC 7 8 9 10 11 12 Software Configuration Now that the Plus X 600 is installed on the network you are ready to add the unit to the ARC Plus using AutoLoad Plus Please download AutoLoad Plus from www burk com if ...

Страница 8: ...scription for the Plus X device The description appears in AutoLoad Plus to identify each Plus X device Enter the IP address and port number of the Plus X 600 These should be the same settings you used when you configured the Plus X 600 via the web Check the Map default set of channels box if you wish to automatically add the Plus X 600 channels to the ARC Plus recommended The ARC Plus must have 1...

Страница 9: ...00 channel you wish to use Click OK Once mapped each Plus X 600 channel will appear on the front panel of the ARC Plus in AutoPilot on the ARC Plus web page and will be accessible via the ESI Uploading New Firmware You can load new firmware to the Plus X 600 using its onboard web interface Navigate to the IP address of the Plus X 600 log on navigate to the Settings page and click the Upload Firmwa...

Страница 10: ...chase Equipment will be repaired or replaced at the option of Burk Technology and returned freight prepaid to the customer Damage due to abuse or improper operation or installation of the equipment or caused by fire or flood or harsh environment is not to be covered by this warranty Damage in shipping is not the responsibility of Burk Technology A return authorization must be obtained before retur...

Страница 11: ...47 63Hz 1A power entry module with standard grounded power cord supplied 1A fuse protection Connectivity Ethernet connection to ARC Plus Channel Capacity 16 status 8 metering and 6 command channels Metering Input Range 10VDC to 10VDC Metering Input Accuracy 99 75 accuracy full scale Status Input Range 0 to 28VDC or switch closure Output Types C NO NC relay outputs momentary or latching 5A 240VAC ...