Temperature sensors use RJ12 jacks for easy connection to the RJ splitter.  Use the supplied 4-way RJ 
splitter or you can use the SENSORS port with couplers and splitters. 

TEMP

OUTDOOR Sensor  

1.

 

Attach the ring of the TEMP-OUTDOOR  with the supplied #6 sheet metal screw, or use any existing 
post, hook or machine screw.  

2.

 

Route the cable to the ARC Solo.  

3.

 

Plug the connector of the TEMP-OUTDOOR  into one of the four available input jacks on the RJ11 
Splitter. If an extension cable is required, only the center two conductors of an RJ12 cable need to 
be extended, corresponding to pins 3 and 4 on the RJ12 connector.  

TEMP

INDOOR Sensor 

You can use the Burk 25’ 6

-conductor cable (part number SENSOR CABLE) to connect the sensor to the 

ARC Solo. If a different cable is used, note that only two conductors are required, corresponding to pins 
3 and 4 on the RJ12 connector. The cable must reverse the connections from one end to the other so 
that pin 4 on the TEMP-INDOOR sensor connects to pin 3 on the ARC Solo splitter and pin 3 on the 
TEMP-INDOOR sensor connects to pin 4 on the ARC Solo splitter.  

1.

 

Secure the sensor in the desired location and connect an RJ12 cable. 

2.

 

Route the cable to the ARC Solo splitter.  

3.

 

Plug the connector of the TEMP-INDOOR  into one of the four available input jacks on the splitter. 

TEMP

WALLMOUNT Sensor  

The TEMP-WALLMOUNT 

comes with a 14’ cable prewired to its internal terminal block

, as shown below:

 

Terminal

 

Usage

 

1

 

No Connection

 

2

 

Red

 

3

 

Green

 

4

 

No Connection

 

For long cable runs, you can supply your own wiring. 

 

                              

 

1.

 

Position the back half of the enclosure against the surface where the TEMP-WALLMOUNT  will 
mount.  

2.

 

Using the enclosure as a template, mark reference circles at each of the two mounting slots and the 
cable entry point.  

Содержание STM-4D

Страница 1: ...STM 4D ARC Solo Digital Temperature Module Sensors Installation and Operation Manual ...

Страница 2: ...UTDOOR Sensor 3 TEMP INDOOR Sensor 3 TEMP WALLMOUNT Sensor 3 TEMP STACK Sensor 3 Installation 4 TEMP OUTDOOR Sensor 4 TEMP INDOOR Sensor 4 TEMP WALLMOUNT Sensor 4 TEMP STACK Sensor 5 Remote Control Setup 5 ARC Solo 5 Cable Orientation and Pinouts 6 Daisy Chain Connection of Digital Sensors 7 Specifications 8 Connectors 8 Temperature Range 8 Cables 8 Getting Help 9 Warranty 9 ...

Страница 3: ...king The following items are included with your purchase of STM 4D TEMP OUTDOOR Digital Temperature Sensor RJ11 4 way splitter License key to activate the Sensors port on your ARC Solo Extending Sensor Cables Sensor cables up to 1000 feet long are supported without measurement degradation You can extend any of the sensors with a standard RJ 12 6 conductor or RJ 11 2 conductor cable Ensure that the...

Страница 4: ...e with RJ 12 connectors on both ends part number SENSOR CABLE or supply your own TEMP WALLMOUNT Sensor The TEMP WALLMOUNT Sensor is housed in a 2 5 8 x 5 enclosure with air vents to facilitate sensing of the environment 14 of cable is provided with an RJ 12 connector on one end The TEMP INDOOR has a large easy to connect barrier strip that accommodates flat or Phillips type screwdrivers TEMP STACK...

Страница 5: ...ferent cable is used note that only two conductors are required corresponding to pins 3 and 4 on the RJ12 connector The cable must reverse the connections from one end to the other so that pin 4 on the TEMP INDOOR sensor connects to pin 3 on the ARC Solo splitter and pin 3 on the TEMP INDOOR sensor connects to pin 4 on the ARC Solo splitter 1 Secure the sensor in the desired location and connect a...

Страница 6: ... there are no obstructions on the inside of the ducting or cavity 2 Using the mounting base as a template mark the location of all mounting holes 3 Drill or cut a hole approximately 3 4 in diameter for the TEMP STACK probe 4 Thread the 3 8 brass pipe fitting onto the base and secure the base to the surface using the supplied sheet metal screws 5 Insert the TEMP STACK into the brass mount and secur...

Страница 7: ...pin 4 as shown below Crossover Wiring Burk s 25 SENSOR CABLE follows this convention A crossover cable such as Burk s SENSOR CABLE must be used for the temp sensors to operate correctly The RJ12 Coupler supplied by Burk also has crossover wiring from one connector to the other Certain sensors including the TEMP STACK TEMP OUTDOOR and TEMP WALLMOUNT come pre wired with a cable terminated in a male ...

Страница 8: ...s to pin 2 and so forth as shown below Straight through Wiring The Burk 25 SENSOR CABLE DAISY CHAIN and RJ12 SPLITTER each use straight through wiring Daisy Chain Connection of Digital Sensors Multiple digital temperature sensors can be connected to ARC Solo using a daisy chain arrangement This can be accomplished by first plugging one RJ12 SPLITTER into each TEMP INDOOR as shown below Plug one RJ...

Страница 9: ...he daisy chain as shown in the diagram below Daisy Chain Wiring of Digital Sensors Specifications Connectors 4 RJ12 jacks for use with TEMP INDOOR TEMP OUTDOOR TEMP STACK and TEMP WALLMOUNT sensors Temperature Range Sensors 55 C to 125 C 0 5C from 10C to 85C Cables TEMP INDOOR Requires Burk SENSOR CABLE not included TEMP WALLMOUNT Includes 14 prewired cable TEMP OUTDOOR Includes 25 prewired cable ...

Страница 10: ...pment or caused by fire or flood or harsh environment is not to be covered by this warranty Damage in shipping is not the responsibility of Burk Technology A return authorization must be obtained before returning any equipment Materials returned under this warranty must be shipped freight prepaid and insured in the original shipping carton or suitable substitute to Burk Technology Inc 7 Beaver Bro...

Отзывы: