BURK Technology STM-4D Скачать руководство пользователя страница 10

STM-4D Installation and Operation Manual Rev B 

 

Getting Help  

For technical support, please email [email protected] or call our direct technical support line at 978‐
486‐3711. We will be glad to assist you. The technical support office is open Monday –

 Friday, 9AM to 

5PM Eastern Time.  

Warranty  

Burk Technology, Inc. warrants the STM-4D, TEMP-INDOOR, TEMP-OUTDOOR, TEMP-WALLMOUNT AND 
TEMP-STACK to be free of defects in materials and workmanship for a period of 24 months from the 
date of purchase. Equipment will be repaired or replaced at the option of Burk Technology and returned 
freight prepaid to the customer. Damage due to abuse or improper operation or installation of the 
equipment or caused by fire or flood or harsh environment is not to be covered by this warranty. 
Damage in shipping is not the responsibility of Burk Technology. A return authorization must be 
obtained before returning any equipment. Materials returned under this warranty must be shipped 
freight prepaid and insured in the original shipping carton or suitable substitute to Burk Technology, 
Inc., 7 Beaver Brook Road, Littleton, MA 01460. Repairs not covered under this warranty will be made at 
prevailing shop rates established by Burk Technology.  

THE WARRANTY SET FORTH ABOVE IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, 
INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A 
PARTICULAR PURPOSE. BURK TECHNOLOGY, INC. SHALL NOT BE LIABLE TO ANY PARTY FOR ANY 
INCIDENTAL, SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS 
EQUIPMENT. 

Содержание STM-4D

Страница 1: ...STM 4D ARC Solo Digital Temperature Module Sensors Installation and Operation Manual ...

Страница 2: ...UTDOOR Sensor 3 TEMP INDOOR Sensor 3 TEMP WALLMOUNT Sensor 3 TEMP STACK Sensor 3 Installation 4 TEMP OUTDOOR Sensor 4 TEMP INDOOR Sensor 4 TEMP WALLMOUNT Sensor 4 TEMP STACK Sensor 5 Remote Control Setup 5 ARC Solo 5 Cable Orientation and Pinouts 6 Daisy Chain Connection of Digital Sensors 7 Specifications 8 Connectors 8 Temperature Range 8 Cables 8 Getting Help 9 Warranty 9 ...

Страница 3: ...king The following items are included with your purchase of STM 4D TEMP OUTDOOR Digital Temperature Sensor RJ11 4 way splitter License key to activate the Sensors port on your ARC Solo Extending Sensor Cables Sensor cables up to 1000 feet long are supported without measurement degradation You can extend any of the sensors with a standard RJ 12 6 conductor or RJ 11 2 conductor cable Ensure that the...

Страница 4: ...e with RJ 12 connectors on both ends part number SENSOR CABLE or supply your own TEMP WALLMOUNT Sensor The TEMP WALLMOUNT Sensor is housed in a 2 5 8 x 5 enclosure with air vents to facilitate sensing of the environment 14 of cable is provided with an RJ 12 connector on one end The TEMP INDOOR has a large easy to connect barrier strip that accommodates flat or Phillips type screwdrivers TEMP STACK...

Страница 5: ...ferent cable is used note that only two conductors are required corresponding to pins 3 and 4 on the RJ12 connector The cable must reverse the connections from one end to the other so that pin 4 on the TEMP INDOOR sensor connects to pin 3 on the ARC Solo splitter and pin 3 on the TEMP INDOOR sensor connects to pin 4 on the ARC Solo splitter 1 Secure the sensor in the desired location and connect a...

Страница 6: ... there are no obstructions on the inside of the ducting or cavity 2 Using the mounting base as a template mark the location of all mounting holes 3 Drill or cut a hole approximately 3 4 in diameter for the TEMP STACK probe 4 Thread the 3 8 brass pipe fitting onto the base and secure the base to the surface using the supplied sheet metal screws 5 Insert the TEMP STACK into the brass mount and secur...

Страница 7: ...pin 4 as shown below Crossover Wiring Burk s 25 SENSOR CABLE follows this convention A crossover cable such as Burk s SENSOR CABLE must be used for the temp sensors to operate correctly The RJ12 Coupler supplied by Burk also has crossover wiring from one connector to the other Certain sensors including the TEMP STACK TEMP OUTDOOR and TEMP WALLMOUNT come pre wired with a cable terminated in a male ...

Страница 8: ...s to pin 2 and so forth as shown below Straight through Wiring The Burk 25 SENSOR CABLE DAISY CHAIN and RJ12 SPLITTER each use straight through wiring Daisy Chain Connection of Digital Sensors Multiple digital temperature sensors can be connected to ARC Solo using a daisy chain arrangement This can be accomplished by first plugging one RJ12 SPLITTER into each TEMP INDOOR as shown below Plug one RJ...

Страница 9: ...he daisy chain as shown in the diagram below Daisy Chain Wiring of Digital Sensors Specifications Connectors 4 RJ12 jacks for use with TEMP INDOOR TEMP OUTDOOR TEMP STACK and TEMP WALLMOUNT sensors Temperature Range Sensors 55 C to 125 C 0 5C from 10C to 85C Cables TEMP INDOOR Requires Burk SENSOR CABLE not included TEMP WALLMOUNT Includes 14 prewired cable TEMP OUTDOOR Includes 25 prewired cable ...

Страница 10: ...pment or caused by fire or flood or harsh environment is not to be covered by this warranty Damage in shipping is not the responsibility of Burk Technology A return authorization must be obtained before returning any equipment Materials returned under this warranty must be shipped freight prepaid and insured in the original shipping carton or suitable substitute to Burk Technology Inc 7 Beaver Bro...