TSE BUSINESS 5000
English |
12
TSE Set 5012 FINGERSCAN
The electronic cylinder operates using a fingerscan. In addition, the cylinder
can be operated by entering the 6-digit numeric code, or also using the
optionally delivered TSE 5103 E-KEY.
In add. to that, you can also use the 6-digit numeric code, as well as
the TSE 5103. E-Key in order to control the cylinder.
Up to 24 fingers can be programmed using the keypad. The users are
created separately (USER XXX_FP). If a code and / or an E-KEY should
additionally be assigned to a user, it needs to be created separately.
Attention!
The finger scanner must not be cleaned with detergents.
Please use a slightly moist cloth for this purpose.
TSE 5012 FINGERSCAN functions (standard)
– Total number of users: up to 48, out of which 24 can
be programmed with fingerscan
– One E-KEY can be assigned to each code user
(except administrator)
– Also a code can be assigned to every E-KEY user
Optional locking media
– TSE 5103 E-KEY
Additional functions available using the optional
TSE Software, for example:
– User administration
– Time and calendar functions
– Assignment of authorizations
– History functions
Technical data
Blocking times
After 3 × wrong code is entered 1 minute, then
always 3 minutes
Display
Adjustable to 12 languages
Power supply for
keypad
4 x MIGNON LR6 AA ALKALINE
Power supply for
cylinder
2 x MIGNON LR6 AA ALKALINE
Permissible
ambient
conditions*
-15 °C / +50 °C / up to 93 % rel. air humidity
(noncondensing)
Allowed temperature range: -20 °C / +50 °C
As a result of extreme temperature changes, the
display can react slowly or darken.
*
In case the temperature exceeds the specified range, a corresponding
warning message is indicated on the display. Provide for appropriate
corrective action!
Attention: The TSE Keypad unit shall not be directly exposed to
outdoor environment. Precipitations and sunshine can damage
the sensor!
Administrator code
– Factory set to 1-2-3-4-5-6 (please be sure to change it)
Power supply
– 6 x MIGNON LR6 AA ALKALINE
Optical signalling
The optical signal in form of a LED is incorporated in the knob on
the inner side of the door. This LED informs you on the following:
– 1 x brief: lock has been opened
– 2 x brief: lock has been shut
– every 5 sec. 1 × brief: permanent opening activated
– 1 × brief, 1 × long, 2 sec. pause, repetition:
lock in programming mode
– 5 × brief, 2 sec. pause, repetition after 20 sec.:
cylinder battery empty