background image

TSE BUSINESS 5000

English 

|

 

11 

5. Storing a user with fingerprint*

–   Press the 

On / Enter

 key

–   The indication of 

Code / Fingerp

 is displayed

–  Press the 

Function 

key

–  The 

Change code

 menu is displayed

–   By pressing the key 

2

 reach the 

Administrator

 menu

–  Press the 

On / Enter 

key

– 

 Admin setup Create user

 is displayed

–  Press the 

On / Enter 

key

–   By pressing the key 

2

 several times reach the 

Create fingerscan menu

–   Press the 

Function 

key

–   At this point you are asked to enter the admin.  

Code (factory setting 

123456

)

–   The indication of 

Create fingerscan 

is displayed

–   The indication of 

Store finger

 is displayed

–   Please pull your finger over the sensor for several times according  

to the instructions shown on the display

–   After a successful entry the indication 

User xxx successfully created

  

is displayed

Attention:

 When saving a fingerprint it is important that the finger is laid 

evenly and in a straight position over the sensor. Follow the instructions 
on the display. The finger is saved only when it can be read in an optimum 
quality.

6. Opening with fingerprint*

–   Press the 

On / Enter

 key

–  The indication of 

Code / Fingerp

 is displayed

–  Move the saved finger over the sensor
–   

Value not achieved

 is displayed for a short time

–   The 

Code / Fingerp

 indication is displayed

–   At this point, enter an additional opening code.
–   The instruction 

Please turn knob

 is displayed

7. Deleting a finger*

–  Press the 

On / Enter

 key

–  The indication of 

Code / Fingerp

 is displayed

–   Press the 

Function

 key

–  The 

Change code

 menu is displayed

–  By pressing the key 

2

 reach the 

Administrator

 menu

–  Press the 

On / Enter

 key

– 

Admin setup Create user

 is displayed

–   By pressing the key 

2

 reach the 

Admin. setup Delete menu

–   Press the On / Enter key
–  Delete user

 is displayed

–   Press the 

On / Enter

 key

–   

At this point you are asked to enter the admin.  
Code (factory setting 

123456

)

–   Now you have to select the appropriate user by pressing the keys 

1

 or 

2

–   Press the 

On / Enter

 key

–   The indication of 

Delete data

 to be confirmed with the 

On key

 

is displayed.

–   Press the 

On / Enter

 key

–   The indication of 

Data record deleted

 is displayed

Additional users can be deleted using the On / Enter key. By pressing the 
Function key, you can reach higher menu levels up to the code entry.

2.5 Error messages*

The following error messages are indicated when a finger is being  
saved or the safe opened:

Error message

Elimination of causes

too fast!  
please repeat

Move the finger more slowly over the sensor

too aslant!  
please repeat

Move the finger straight over the sensor

too short!  
please repeat

 

Move the finger over the sensor in a way allowing 
more surface area to be rea

place to the center 
and repeat!

Place your finger centrally over the sensor

Содержание Tresor TRSE 6000

Страница 1: ...ER KG Altenhofer Weg 15 58300 Wetter Germany TRSE 6000 TRSE 6000 TRSE 6000 FS TRSE 6000 FS BA MA TESE 6000 dp fsc 02 2012 Bedienungsanleitung User Manual Manuel d utilisation Gebruiksaanwijzing Tresor Nutzen Sie drei Arten zum Öffnen ...

Страница 2: ...s are stored in the system with a value of In order to acquire the authorization to open a value of at least 1 must be achieved A pin code with a value of at least must be therefore entered for the opening a value of 1 can be also achieved with an additional fingerscan Attention The values can only be adjusted using TSE Light TSE System and System software When a PIN code user or an E Key user is ...

Страница 3: ...as either a code or an E Key or both A separate user is always created for a fingerscan Anatomically there are people the fingerprints of whom are not sufficiently articulated for the system Assign E Key An E Key can be additionally assigned to a selected user here Delete Users and E Keys can be deleted here When a user is deleted also the code and the E Key belonging to the user are deleted When ...

Страница 4: ... Channel Admin Setup Priority Delete User Delete E Key Connection Channel Restructuring in progress Free space not available Data are stored Data are stored Data are stored Data are stored Data are stored Data are stored Wrong Code Please repeat Delete Data by pressing ON Taste Priority Admin Setup Restructure Admin Setup Install Keyboard Admin Setup FS Reset E Key in prog Mode cont with ENTER Adm...

Страница 5: ...up Create user is displayed Press the On Enter key Create code is displayed Press the On Enter key At this point you are asked to enter the Admin Code factory setting 123456 The indication of User 00x is displayed Please enter the user code and confirm it with ENTER Press the On Enter key FS combination to be confirmed with ENTER is displayed1 Press the On Enter key and accordingly the Function ke...

Страница 6: ...ication is displayed At this point enter an additional opening code The instruction Please turn knob is displayed 7 Deleting a finger Press the On Enter key The indication of Code Fingerp is displayed Press the Function key The Change code menu is displayed By pressing the key 2 reach the Administrator menu Press the On Enter key Admin setup Create user is displayed By pressing the key 2 reach the...

Страница 7: ...TSE BUSINESS 5000 22 Batterien Batteries Batterijen 2x 1 5V Mignon LR6 Codeeingabe Code entry Entrée code Code invoer 5 Batteriewechsel Replacement of batteries Changer la batterie Batterijwissel ...

Отзывы: