TSE BUSINESS 5000

English |

 

TSE Set 5012 FINGERSCAN

The electronic cylinder operates using a fingerscan. In addition, the  
cylinder can be operated by entering the 6-digit numeric code, or also  
using the optionally delivered TSE 5103 E-KEY.
In add. to that, you can also use the 6-digit numeric code, as well as 
the TSE 5103. E-Key in order to control the cylinder.

Up to 24 fingers can be programmed using the keypad. The users are 
created separately (USER XXX_FP). If a code and / or an E-KEY should 
additionally be assigned to a user, it needs to be created separately. 

Attention! 

The fingerscanner must not be cleaned with detergents. 

Please use a slightly moist cloth for this purpose.

TSE 5012 FINGERSCAN functions (standard)

–   Total number of users: up to 48, out of which 24 can  

be programmed with fingerscan

–  One E-KEY can be assigned to each code user (except administrator)
– Also a code can be assigned to every E-KEY user

Optional locking media

–   TSE 5103 E-KEY

Additional functions available using the optional TSE Software,  
for example:

– User administration
– Time and calendar functions
– Assignment of authorisations
– History functions

Administrator code

– Factory set to 1-2-3-4-5-6 (please be sure to change it)

Optical signalling

The optical signal in form of a LED is incorporated in the knob on 
the inner side of the door. This LED informs you on the following:
– 1 x brief: lock has been opened
– 2 x brief: lock has been shut
– every 5 sec. 1 × brief: permanent opening activated
– 1 × brief, 1 × long, 2 sec. pause, repetition: lock in programming mode
– 5 × brief, 2 sec. pause, repetition after 20 sec.: cylinder battery empty

Technical data

Blocking times

After 3 × wrong code is entered 1 minute,  
then always 3 minutes

Display

Adjustable to 12 languages

Power supply for 
keypad

2 x MIGNON LR6 AA ALKALINE

Power supply for 
cylinder

2 x MIGNON LR6 AA ALKALINE

Permissible ambient 
conditions

*

-15 °C / +50 °C / up to 93 %
rel. air humidity (noncondensing)
Allowed temperature range: -20 °C / +50 °C

As a result of extreme temperature changes, the 
display can react slowly or darken.

Keypad protection class

IP55

*  

In case the temperature exceeds the specified range, a corresponding warning message is 

indicated on the display. Provide for appropriate corrective action!

Содержание TSE 5011

Страница 1: ...ic door lock BUSINESS Ingeniously safe Ingeniously simple BA MA TSE Set 5000 dp fsc 11 2015 Assembly and User Manual SET 5013 E KEY SET 5011 PINCODE SET 5012 FINGERSCAN BURG WÄCHTER KG Altenhofer Weg 15 58300 Wetter Germany ...

Страница 2: ...he Function button In the menu the buttons 1 and 2 can be used as a scroll function to navigate through its structure 2 Deleting an entry action When the Func C symbol is displayed the last entry can be cancelled by pressing the Function button 3 Entry into the previous programming level Back When you are in the menu the symbol Func is displayed By pressing the Function button you return into the ...

Страница 3: ...f the door This LED informs you on the following 1 x brief lock has been opened 2 x brief lock has been shut every 5 sec 1 brief permanent opening activated 1 brief 1 long 2 sec pause repetition lock in programming mode 5 brief 2 sec pause repetition after 20 sec cylinder battery empty Technical data Blocking times After 3 wrong code is entered 1 minute then always 3 minutes Display Adjustable to ...

Страница 4: ...SE Software for example User administration Time and calendar functions Assignment of authorisations History functions Administrator code Factory set to 1 2 3 4 5 6 please be sure to change it Optical signalling The optical signal in form of a LED is incorporated in the knob on the inner side of the door This LED informs you on the following 1 x brief lock has been opened 2 x brief lock has been s...

Страница 5: ...f a LED is incorporated in the knob on the inner side of the door This LED informs you on the following 1 x brief lock has been opened 2 x brief lock has been shut every 5 sec 1 brief permanent opening activated 1 brief 1 long 2 sec pause repetition lock in programming mode 5 brief 2 sec pause repetition after 20 sec cylinder battery empty Opening The TSE depending on thr version can be operated b...

Страница 6: ... to be registered several times centrally over the sensor the number of moves is indicated on the display User_XXX_FP successfully registered is displayed Submenu Assign E KEY Using this function you can subsequently assign an E KEY radio code to an already existing user For this purpose proceed as follows Activate the keypad using the key Then press FUNC the Code Change menu is displayed Scroll u...

Страница 7: ...hough E KEYs with the old channel setup are still in use Activate the keypad using the key Then press FUNC the Code Change menu is displayed Scroll using the 1 or 2 keys until reaching the KEY synchronization menu Confirm with Enter the administrator code of unit that needs to be synchronised Data has been saved is displayed after a successful registration Attention Make sure that no other powered...

Страница 8: ...ting the process e g in 65 C the full adhesive force will be achieved in one hour When gluing the holder plate on the colour sight protection film the above described conditions relating to cleanliness of surfaces and firmness of the adhesive pad should be observed To provide for a bubble free application of the colour sight protection film please proceed as follows Pour some water with a couple o...

Страница 9: ...ling it out Outer side Inner side Outer knob Inner knob Cover Adapter 2 Adapter 1 Detent bolt Locking screw for fixation onto the shaft Remark The base size of the cylinder is 30 mm per side When delivered the cylinder is completely collapsed the smallest door thickness Before you insert the cylinder into the door you should adjust it to your door thickness When installing the cylinder proceed as ...

Страница 10: ...key you can provide access in case of failure of the system 1 Swing the emergency key open and then insert it into the indicted slot in the cover panel 2 Turn the key 90 clockwise If required move the outer knob slightly to the right and left in order to release the mechanism 3 Turn the outer knob The lock opens when fully turned at the latest Turn the key to its initial position and take it out T...

Отзывы: