10
08/54070/0 (Issue 6)
The appliance is supplied with a terminal block suitable for flexible wires up to 6mm².
Always destroy a plug that has been removed from the mains lead as a plug with bared flexible cord
is hazardous, if plugged into a live socket outlet.
7.5 6kW Twin Tap Model
The 6kW appliance is supplied with an internal terminal block for connection to the main power supply.
This must be connected using suitable flexible cable. The supply end of the cord must be fitted with an
easily accessible, all pole disconnection isolator switch, with a minimum of 3mm contact separation. For
safety regulations the means of disconnection must be accessible after installation.
7.6 Overflow and Drainage
Due to the electronic function of this water boiler, it is highly unlikely that an overflow would occur. The
boiler is primarily designed so that any overflow occurrence and condensation is directly vented to the
spillage tray. As an option, the boiler overflow outlet may be connected to a drainage system.
There may be some steam emitted from the vent at the base of the appliance during the initial fill
stages (or if the tank is refilled after being fully emptied) but this will reduce as the volume of water
increases in the tank. As an alternative, a flexible hose may be used to redirect steam to a sink/draining
board.
The flexible hose connected from the over flow also acts as a vent for the appliance. Under no
circumstances should this flexible hose become blocked or restricted in any way.
Should the boiler overflow, the water will be collected in the drip tray. The water in the drip tray can then
be emptied out into a drain. Check and empty the drip tray on a regular basis.
Optional drip tray connection to a waste water supply (not supplied).