Burcam 400505H Скачать руководство пользователя страница 4

FOR  INFORMATION      TEL: 514.337.4415   FAX: 514.337.4029

Screw the pipe with the male adaptor into the 2” discharge opening in the pump. Lower pump
with piping attached into the sewage basin. Make sure that the pump is as close as possible
to the centre of the basin. Adjusting the pump in centre of basin will keep mechanical float
switch from rubbing on side of basin.

When you are pumping raw sewage, you must have a gas tight cover on the basin and a vent
pipe from basin, connecting to home’s vent system (see diagram). Feed the 2” riser pipe from
pump’s discharge, through the 2” opening in the cover. Secure a 3” vent pipe to the cover
and bring the switch and pump motor power cables through the opening in the cover
provided.

Install a 2” check valve (model 450457) union type to the 2” discharge riser pipe coming out
of the cover, to a lenght of 2” ABS/DWV pipe, and run the discharge line as short as
possible to the home’s waste sewer line. Secured the check valve with the provided clamps.
Be sure that the arrow on valve are pointing away from pump.

Connect the 3 prong plug of the switch in a receptacle. Insert the motor 3 prong plug into
female receptacle on exposed piggy-back of switch plug. The mechanical switch provided for
automatic operation is preset to pump. No adjustments are necessary.

Fill the sewage basin with water to test the operation of the submersible sewage pump and
switch operation. Pump should start pumping when the water level reaches 12” to 15” above
the bottom of the basin and above the pump. Allow the pump to go several “on-off” cycles to
assure satisfactory operation.

Secure the gas tight cover and the plug for electrical cords with the gaskets and screws
provided with the cover. Make vent connection to home’s vent system.

STEP 5

STEP 6

STEP 7

STEP 8

SEWAGE SYSTEM TYPICAL PIPING

STEP 9

STEP 10

4

Home’s vent system

Raw sewage discharge line

Pump’s discharge line

Basin

vent line

From                      From       From
bath or shower        Toilet       Sink

Sewage basin inlet

Содержание 400505H

Страница 1: ... comply to instructions and designed operation of this system may void the warranty WWW BURCAM COM Your pump has been carefully packaged at the factory to prevent damage during shipping However occasional damage may occur due to rough handling Carefully inspect your pump for damages that could cause failures Report any damage to your carrier or your point of purchase 2008 BUR CAM Printed in Canada...

Страница 2: ...WITH THE POWER CONNECTED DO NOT ONLY UNSCREW THE FUSE OR TRIP THE BREAKER REMOVE THE POWER PLUG FROM THE RECEPTACLE A B C D Material required for sewage pump application Desired length of ABS DWV 2 pipe to link up from pump discharge to waste or drain existing pipe Required quantities of 2 ABS DWV elbow s and or other fitting s to run the discharge line 1 only 2 ABS DWV male adaptor to 2 slip to c...

Страница 3: ...hould be constructed from concrete brick tile or more recently a sump basin made from plastic and or fiberglass The minimum size of your sump pit must be 18 in diameter and no less than 25 deep When pit is ready proceed to next step Friction losses in the discharge pipe must be taken into consideration when many elbows and fittings are installed in the discharge line Each elbows and fittings must ...

Страница 4: ... short as possible to the home s waste sewer line Secured the check valve with the provided clamps Be sure that the arrow on valve are pointing away from pump Connect the 3 prong plug of the switch in a receptacle Insert the motor 3 prong plug into female receptacle on exposed piggy back of switch plug The mechanical switch provided for automatic operation is preset to pump No adjustments are nece...

Страница 5: ... and make vent connection Repair parts may be ordered from your authorized point of sale or from BUR CAM PUMPS REF DESCRIPTION 1 410013 Power cable 2 410017 Power cable adaptor 3 410001 Upper casing 4 410014 Capacitor 5 410002 Upper bearing cover 6 410009 Upper bearing 7 410006 Seal plate 8 410007 Volute base 9 410008 Impeller REF DESCRIPTION 10 410011 Mechanical seal 11 410010 Oil seal 12 350340 ...

Страница 6: ...Clogged check valve in open position Float obstruction Turn switch to on position Replace Reset Re install Clean Check movement Replace Replace Check voltage Check drilled hole in discharge pipe Wrong pump selection over 15 Clean Check voltage Check drilled hole in discharge pipe Wrong pump selection over 15 Clean Replace Install valve Clean debris Check for movement TROUBLE PROBABLE CAUSE ACTION ...