REPLACEMENT PUMP MODELS

10

MODELS HP V Wire Stages

MODELS HP V Wire Stages

MODELS HP V Wire Stages

MODELS HP V Wire Stages

MODELS HP V Wire Stages

MODELS HP V Wire Stages

ALL STAINLESS STEEL 

5 GPM 1 - 1 1/4’’ DISCHARGE

ALL STAINLESS STEEL 

10 GPM 1 - 1 1/4’’ DISCHARGE

NORYL Impellers / Diffusers 

& STAINLESS STEEL 

5 GPM 1 - 1 1/4’’ DISCHARGE

NORYL Suction / Discharge 

& S. STEEL (econo serie) 

10 GPM 1 1/4’’ DISCHARGE

NORYL Impellers / Diffusers 

& STAINLESS STEEL 

7 GPM 1 - 1 1/4’’ DISCHARGE

NORYL Impellers / Diffusers 

& STAINLESS STEEL 

10 GPM 1 - 1 1/4’’ DISCHARGE

101124  1/2 115  2 

13

101125  1/2 115  3 

13

101126  1/2 230  2 

13

101074  1/2 230  3 

13

101134  3/4 230  2 

18

101135  3/4 230  3 

18

101059  3/4 230  3 

18

101144  1.0 230  2 

22

101145  1.0 230  3 

22

101156  1.5 230  2 

26

101154  1.5 230  3 

26

101129 

1/2  115 

  9

101123 

1/2  115 

  9

101130 

1/2  230 

  9

101128 

1/2  230 

  9

101151 

1/2  230 

  9

101131  3/4 230  2 

12

101136  3/4 230  3 

12

101152  3/4 230  3 

12

101147  1.0 230  2 

15

101146  1.0 230  3 

15

101153  1.0 230  3 

15

101158  1.5 230  2 

21

101155  1.5 230  3 

21

101165  2.0 230  3 

27

105130  1/2 115  2 

13

105125  1/2 115  3 

13

105132  1/2 230  2 

13

105127  1/2 230  3 

13

105101  1/2 230  3 

13

105142  3/4 230  2 

18

105135  3/4 230  3 

18

105105  3/4 230  3 

18

105144  1.0 230  2 

22

105145  1.0 230  3 

26

105153  1.5 230  2 

30

105154  1.5 230  3 

30

105335ST  1/2  115 

  6

105305ST  1/2  115 

  6

105337ST  1/2  230 

  6

105307ST  1/2  230 

  6

105551ST  1/2  230 

  6

105339ST  3/4  230 

  8

105309ST  3/4  230 

  8

105352ST  3/4  230 

  8

105335ST 1.0  230  2 

11

105313ST 1.0  230  3 

11

105353ST 1.0  230  3 

11

105336ST 1.5  230  2 

17

105316ST 1.5  230  3 

17

105113  1/2 115  2 

10

105114  1/2 115  3 

10

105131  1/2 230  2 

10

105163  1/2 230  3 

10

105108  1/2 230  3 

10

105141  3/4 230  2 

13

105143  3/4 230  3 

13

105109  3/4 230  3 

13

105173  1.0 230  2 

17

105174  1.0 230  3 

17

105182  1.5 230  2 

22

105183  1.5 230  3 

22

105124 

1/2  115 

  6

105126 

1/2  115 

  6

105133 

1/2  230 

  6

105128 

1/2  230 

  6

105103 

1/2  230 

  6

105134 

3/4  230 

  8

105136 

3/4  230 

  8

105107 

3/4  230 

  8

105150  1.0 230  2 

11

105146  1.0 230  3 

11

105161  1.5 230  2 

15

105155  1.5 230  3 

15

*Bold : Sub Pac models

Should have more choice depending of your configuration.

Содержание 101059

Страница 1: ...hat could cause failures Report any damage to your carrier or your point of purchase INSTALLATION INSTRUCTIONS 101 105 SERIES SUBMERSIBLE DEEP WELL PUMPS or SUB PACS Please read these instructions car...

Страница 2: ...ation 2 Inspect the pressure tank to detect any deterioration 3 Check the condition of the tank T and the proper functioning of the pressure switch 4 Clean the area of any paper or other debris 5 Ensu...

Страница 3: ...the pumping capacity is higher ie providing 7 GPM instead of 5 GPM set the pump deeper in the well provided that the well will support the additional volume BEFORE YOU START Material required for a d...

Страница 4: ...ble around the ends of the tube STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 STEP 6 STEP 7 STEP 8 Shrinking can be accomplished through the use of a thermo gun or flame torch with a utility head or other broad...

Страница 5: ...eroperatingpressures The pressure switch setting was done at the factory start stop 20 40 or 30 50 Adjustment or modification of start stop setting of pressure switch have to be done carefully Turn ad...

Страница 6: ...above the pump s discharge and around the pipe place each half of the arrestor and with the clamps provided install the arrestor Tighten the bottom clamp securely Then push the top portion of the arr...

Страница 7: ...across the diameter of the well casing With the aide of your helper it is now time to lower pump and piping assembly into your well casing Following this operation fix the safety rope to an anchor on...

Страница 8: ...he pump through a few cycles to verify that it works properly Other types of tanks may be used such as galvanized standard tanks epoxy or glass lined tanks However these products do not achieve the be...

Страница 9: ...t outlet connection using an ample supply of teflon tape on the threads Determine the position or location in wich you wish to leave your tank permanently Leave ample room to make your tank connection...

Страница 10: ...1153 1 0 230 3 15 101158 1 5 230 2 21 101155 1 5 230 3 21 101165 2 0 230 3 27 105130 1 2 115 2 13 105125 1 2 115 3 13 105132 1 2 230 2 13 105127 1 2 230 3 13 105101 1 2 230 3 13 105142 3 4 230 2 18 10...

Страница 11: ...10 long bronze tank Tee 1 NPT 5 10 long bronze Tee 1 NPT with union 6 1 bronze pitless adaptor 6 1 1 4 bronze pitless adaptor 6 2 bronze pitless adaptor Models Description 125127 1 2 HP 115V 2 wire 1...

Страница 12: ...e valve Check water level Install pump lower Remove pump and check Check location and change Have electrician check for resistance Replace Call an electrician Motor does not run Motor starts too often...