SERVICE (cont.)
TIMER (First Type)
white/yellow and orange wires from interlock of ECA
and connect harness leads together.
5. Check for continuity across the white/orange and
white/yellow wires on electro/mechanical brewers
or the white/yellow and yellow wires on electronic
brewers when the start switch is pressed.
If continuity is present as described, reconnect the
wires to terminals TL3, TL4 and TL5 of the timer board
and interlock wires if necessary, proceed to #6.
6. With a voltmeter, check the voltage across terminals
TL1 and TL4 when the "ON/OFF" switch is in the
"ON" position. Connect the brewer to the power
source and press the start switch. The indication
must be:
a.)120 volts ac for two wire 120 volt models, three
wire 120/208 volt models and three wire 120/240
volt models for approximately 1 minute for 1-1/2
gallon batch.
b.)200 to 240 volts ac for two wire 200 or 240
volt models for approximately 1 minute for 1-1/2
gallon batch.
7. Select a 1 gallon batch and repeat #6. The voltage
indication should remain for approximately 40
seconds.
8. Select a 1/2 gallon batch and repeat #6. The indica-
tion should remain approximately 20 seconds.
Removal and Replacement:
1. Remove all wires from the timer.
2. Remove the four #6-32 slotted head screws holding
circuit board and dial plate on to the component
mounting bracket.
3. Remove circuit board, nylon spacers and dial
plate.
4. Install new timer circuit board as described in
Digital Timer
section on the following pages.
5. Refer to Fig. 31 when reconnecting wires.
6. Install the timer setting decal provided with the
replacement timer kit, on the inside of the front
access panel.
7. Adjust timer as required. Refer to
Digital Timer
section on the following pages.
Location:
The timer is located inside the left front of the brewer
on the upper part of the component bracket.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the wires from the timer terminals TL3,
TL4 and TL5 and rotate the dial(s) fully counter-
clockwise.
3. With a voltmeter, check the voltage across terminals
TL1 and TL2 when the "ON/OFF" switch is in the
"ON" position. Connect the brewer to the power
source. The indication must be:
a.)120 volts ac for two wire 120 volt models, three
wire 120/208 volt models and three wire 120/240
volt models.
b.)200 to 240 volts ac for two wire 200 or 240 volt
models.
4. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the
Wiring
Diagrams
and check the brewer wiring harness.
NOTE: ECA MODELS ONLY - Brewer must be at op-
erating temperature to perform step #5 or brew-lock
must be bypassed. To bypass brew-lock disconnect
P825
1
2
3
4
5
.5
MINUT
ES
BU
NN-O-MA
TIC
P/N
262
0-
120
VA
C
27038 030901
FIG. 28 TIMER