SERVICE (cont.)
ELECTRONIC CONTROL ASSEMBLY
1. Electronic Control
2. Terminal Block
3. Timer
4. Liquid Level Switch
& Overflow Cup
5. Tank Heater
6. Limit Thermostat
7. Liquid Level Probe
8. Temperature Sensor
9. Dispense Valve
10. Bypass Valve
11. Ready Light
12. Solenoid Valve
13. LED
14. Temperature Adjustment
15. Triac Assy
Location:
The electronic control assembly (1) is located
inside the lower left front on the component bracket
of the brewer. Access will also be needed to the tem-
perature sensor (8), liquid level probe (7) located on
the tank lid and to the triac assembly (15) located
beneath the tank.
General:
This system controls the liquid level and water
temperature of the brewer. These two functions act
independently of each other and should be tested
separately.
BREW START - LOCK
The water must be heated to the preset temperature
indicated by the glowing ready light before a brew cycle
can be initiated.
PROBLEM:
LIQUID LEVEL CONTROL SYSTEM DOES NOT
REFILL
OVERFLOW CUP FULL
YES
REMOVE POWER
DRAIN CUP
RETRY
NO
DISCONNECT LEVEL PROBE
(4)
(4)
(7)
VOLTAGE PRESENT AT
SOLENOID VALVE
(12)
YES
DOES WATER FLOW
YES
REPLACE PROBE
(7)
NO
NO
REPLACE
SOLENOID VALVE
(12)
REPLACE
CONTROL
ASSEMBLY (1)
Liquid Level Control Test Procedure:
1. Disconnect brewer from the power source.
2. With a voltmeter, check the voltage across termi-
nals 3 & 4 of the electronic control assembly (1).
Connect brewer to power source.The indication
must be:
a.)120 volts ac for two wire 120 volt models,208
volts ac for three wire 120/208 volt models and
240 volts ac for three wire 120/240 volt models.
b.) 200 to 240 volts ac for two wire 200 or 240
volt models.
3. Disconnect brewer from the power source.
If voltage was present as described, proceed to #4.
If voltage was not present as described, refer to the wir-
ing diagrams and check the brewer wiring harness.
4. Remove the pink wire from terminal 5 of the elec-
tronic control assembly (1).
5. With a voltmeter, check the voltage across terminals
1 & 4 of the electronic control assembly (1). Con-
nect brewer to the power source. The indication
must be:
22978.0000
CA
UTIO
N
!
WA
RNIN
G
STO
P
15 2 1
6
4
3
7 5 8 12 9 10
11
13
14
P817
If the ready light goes out during a brew cycle,the
cycle will continue until it is completed. You must wait
until the ready light glows before starting another
brew cycle.
27038 030901
FIG. 11 ELECTRONIC CONTROL ASSEMBLY
P830