Page 45
Equipment will not operate.
Brew cycle will not start.
Automatic refill will not operate
or display shows FILL TIME TOO
LONG
1. No power or incorrect voltage.
1. No water
2. ON/OFF switch
3. Brew switch
4. Brew Valve
5. Electronic Control Board
1. No water
2. Water strainer
Measure the voltage at the terminal
block and confirm that it matches
the voltage specified on the brewer
data plate /- 10%.
Check plumbing and shut-off
valves
Test the ON/OFF switch. Refer to
the switch test procedures on page
33.
Test the BREW switch. Refer to the
switch test procedures on page
33.
Test the Brew valve. Refer to
Test-
ing Individual Components
on page
33.
Substitute a control board known to
be in good working order.
Check plumbing and shut-off
valves.
(A) Direction of flow arrow must be
pointing towards direction of water
flow.
(B) Remove the strainer and check
for obstructions. Clear or replace
TROUBLESHOOTING (cont.)
Troubleshooting Procedure
Problem
Possible Cause
35058.1 071205