
Page 21
ENTER OZ XX.X
(-) DONE (+)
NEW BYPAS FLOW
XX.X OZ/M
EXIT TO THE
NEXT FUNCTION
SCREEN
COUNTS DOWN
TO ZERO
BREW PRESSED
AFTER 1 MINUTE
CALIBRATE FLOW?
NO YES
CONTAINER RDY?
NO YES
CALIBRATE BYPASS
PRESS BREW START
CALIBRATE BYPASS
60 SEC TO FINISH
BYPASS CAL?
NO YES
SPRAYHEAD CAL?
NO YES
PROGRAMMING FUNCTIONS -(cont.)
CALIBRATE FLOW (cont.)
Procedures to calibrate the bypass fl ow rate:
1. Place a container, accurately graduated in ounces,
and with a minimum capacity of 60 ounces, below
the funnel on the brewer.
2. Press and hold upper right hidden switch until the
display reads
SET NEW RECIPES
. Release switch.
Press and release upper right hidden switch until
the display reads
CALIBRATE FLOW?
.
3. Press and release
YES
to advance to the
SPRAY
HEAD CAL?
function screen. (Pressing
NO
in the
CALIBRATE FLOW
screen will advance to the next
function screen,
BREW COUNTERS).
4. Press and release
NO
to advance to the
BYPASS
CALIBRATION
screen.
5. Press and release the
YES
pad. The display should
read
CONTAINER READY?
If the container is
under the funnel, press
YES.
The display should
read
CALIBRATE BYPASS .. PRESS BREW TO
START.
6. Press and release the
pad. The display should
read
CALIBRATE BYPASS .. 60 SEC TO FINISH.
The
60 second timer on the display will count down to
zero. When the counter reaches zero, the display
will change to
ENTER OZ.,
along with a number
signifying ounces per minute.
7. Measure the amount of water in the container, and
using
(-)
or
(+)
, adjust the amount on the display
to match the amount in the container. Then press
DONE
.
8. The display should now read
NEW BYPASS FLOW
,
along with the correct fl ow rate of the bypass in
ounces per minute. After about 5 seconds, the dis-
play will return to the
CALIBRATE FLOW
screen.
9. To
exit
the
CALIBRATE FLOW
function, press and
release
NO
to advance to the next function screen,
or press and release the
pad located on the
front switch panel to exit the
CALIBRATE FLOW
function and return to the
MAIN SCREEN.
P2314
34025.1 011006