Procedure to adjust the fl ow rate setting:
1. Press and hold upper right hidden switch until the
display reads
SET NEW RECIPES
. Release switch.
Press and release upper right hidden switch until
the display reads
BYPASS OZ/M
. The number
represents what the brewer thinks is the fl ow rate
of the bypass valve in ounces per minute.
2. If the actual fl ow rate of the bypass valve is known,
but is different than the number on the display, use
the
(-)
and
(+)
pads to enter the correct fl ow rate
in ounces per minute.
3. When fi nished, press and release the
DONE
pad.
This saves the new setting and advances to the
next function screen,
CALIBRATE FLOW.
Another
alternative is to press and release the
pad lo-
cated on the front switch panel to exit the
BYPASS
OZ/M
function and return to the
MAIN SCREEN.
CALIBRATE FLOW
This function allows the operator to enter the actual
fl ow rate of the sprayhead and the bypass by dispens-
ing both separately for one minute. The volumes are
then entered in ounces per minute (OZ/M).
Procedures to calibrate the sprayhead fl ow rate:
1. Place a container, accurately graduated in ounces,
and with a minimum capacity of 60 ounces, beneath
the funnel on the brewer.
2. Press and hold upper right hidden switch until the
display reads
SET NEW RECIPES
. Release switch.
Press and release upper right hidden switch until
the display reads
CALIBRATE FLOW ?
.
3. Press and release
YES
to advance to the
SPRAY
HEAD CAL?
function screen. (Pressing
NO
in the
CALIBRATE FLOW
screen will advance to the next
function screen,
BREW COUNTERS).
4. Press and release the
YES
pad. The display should
read
CONTAINER READY?
If the container is under
the funnel, press
YES.
The display should read
CALIBRATE SPRAY .. PRESS BREW TO START.
5. Press and release the
pad. The display should
read
CALIBRATE SPRAY .. 60 SEC TO FINISH.
The
60 second timer on the display will count down to
zero. When the counter reaches zero, the display
will change to
LEFT
or
RIGHT OZ.,
along with a
number signifying ounces per minute.
6. Measure the amount of water in the container and
using the
(-)
or
(+)
pads, adjust the amount on
the display to match the amount in the container.
P2307
PROGRAMMING FUNCTIONS - (cont.)
NEW SPRAY FLOW
XX.X OZ/M
ENTER OZ XX.X
(-) DONE (+)
CALIBRATE FLOW?
NO YES
SPRAYHEAD CAL?
NO YES
CONTAINER RDY?
QUIT YES
CALIBRATE SPRAY
PRESSBREWSTART
CALIBRATE SPRAY
60 SEC TO FINISH
COUNTS DOWN
TO ZERO
AFTER 1 MINUTE
BREW PRESSED
EXIT TO THE
NEXT FUNCTION
SCREEN
Then press
DONE
.
7. The display should now read
NEW SPRAY FLOW
,
along with the correct fl ow rate of the sprayhead
in ounces per minute. After about 5 seconds,
the display will return to the
CALIBRATE FLOW
screen.
8. To exit the
CALIBRATE FLOW
program, press
NO
to advance to the next function screen, or press
and release the
pad located on the front switch
panel to exit the
CALIBRATE FLOW
function and
return to the
MAIN SCREEN.