TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. 

If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department.

•  Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.

•  All electronic components have 120-240 volt ac and low voltage dc potential on their terminals. Shorting of terminals 

or the application of external voltages may result in board failure.

•  Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an intermittent 

condition is encountered, the cause will likely be a switch contact or a loose connection at a terminal or crimp.

•  Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are energized for 

more than ten minutes without a supply of water.

•  The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help to avoid 

twists and kinks in the tubing.

•  Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

WARNING  –  •  Exercise extreme caution when servicing electrical equipment.

 

  •  Unplug the dispenser when servicing, except when electrical tests are specified.

 

  •  Follow recommended service procedures.

 

  •  Replace all protective shields or safety notices.

No collar/foam created during a  

Nitro Coffee Brew dispense.

Weak or inconsistent collar/foam 

on the Nitro Coffee Brew.

1. No power to Nitron Gas Module.

2. Thermal overload tripped in Nitron 

Gas Module.

3. Nitron Gas Module start capacitor.

1. Leak in gas line or continuous 

Nitron Gas Module operation.

2. Nitron Gas Module prefilter dirty.

3. Nitron Gas Module desiccant filter 

absorption capability depleted.

4. nitron

2

 Cold Draft Dispenser:

a) Cleanliness of nitro dispense 

nozzle.

b) Stout insert missing in nitro 

nozzle.

Check outlet for power and within 

acceptable voltage range.

a) Wait for thermal overload to cool 

down and reset.

b) Relocate or correct environ-

ment conditions around Nitron Gas 

Module.

Replace start capacitor.

Rating: 250VAC, 50/60Hz

7.0µF (-5/+10%)

Inspect pressurized line (tubing) 

between the Nitron Gas Module and 

Nitron

 

dispenser for a leak. Inspect 

the Nitron dispenser internal tubing 

for a leak.

Replace prefilter.

Replace desiccant filter.

a) Clean Nitro Coffee dispense 

nozzle assembly.

b) Install new Stout Insert into the  

Nitro Coffee dispense nozzle.

PROBLEM

PROBABLE CAUSE

REMEDY

Содержание NITRON2 NGM

Страница 1: ...D 07 19 2019 Bunn O Matic Corporation INSTALLATION OPERATING GUIDE Bunn O Matic Corporation Post Office Box 3227 Springfield Illinois 62708 3227 Phone 217 529 6601 Fax 217 529 6644 www bunn com NGM Ni...

Страница 2: ...or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive op tion while...

Страница 3: ...e Maintenance 8 Troubleshooting 9 Wiring Schematic 11 INTRODUCTION The Nitron Gas Module NGM is specifically designed to work with Nitron Cold Draft dispensers It sup plies an unlimited amount of gas...

Страница 4: ...o not direct air stream at body To reduce Risk of Injury WARNING FAILURE TO COMPLY RISKS EQUIPMENT DAMAGE FIRE OR SHOCK HAZARD READ THE ENTIRE OPERATING MANUAL BEFORE USING THIS PRODUCT 00986 0002M 10...

Страница 5: ...uthorized Service personnel only CE REQUIREMENTS This appliance must be installed in locations where it can be overseen by trained personnel For proper operation this appliance must be installed where...

Страница 6: ...ot connect the grounding wire to either flat blade terminal The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire Contact a qualified elec...

Страница 7: ...ing with Step 2 Step 2 Place the Nitron Gas Module NGM near or under the Nitron dispenser Adjust to extend the feet of the Nitron dispenser approximately 1 0 inch to accommodate NGM placement undernea...

Страница 8: ...d product for the consumer Assures uptime Eliminate premature replacing of equipment Reduce problematic repairs return service trips NGM Annual PM For optimal performance all four internal filters sho...

Страница 9: ...sealed and electrical connections tight and isolated WARNING Exercise extreme caution when servicing electrical equipment Unplug the dispenser when servicing except when electrical tests are specifie...

Страница 10: ...icted Nitron Gas Module filter Inspectentirepressurizedlinefrom Nitron Gas Module to the nitron2 Cold Draft dispenser Ensure proper Nitron Gas Module placementaccordingtoSiterequire ments Replace miss...

Страница 11: ...ION SCHEMATIC WIRING DIAGRAM NITRON GAS MODULE 120 VOLTS AC 2 WIRE SINGLE PHASE 60hZ GRN WHI BLK 120V MODELS N A B A B L1 SOLENOID VALVE SOL BLU BLU AIR PUMP PRESSURE SWITCH MOTOR START CAPACITOR WHI...

Отзывы: