7
SWEETENER CALIBRATION
(continued)
NOTE: Only perform if you have a 40 ounce or 1000 milliliter container available with 1 ounce
or 1 milliliter increments.
NOTE: Conversion for ml to oz: multiply by .033814.
Conversion for oz to ml: multiply by 29.5735.
1. Press and hold right hidden button until the display
reads CALIBRATE FLOW?.
2. Press the right hidden button again.
3. Continue untill PASSWORD screen appears.
NOTE:
Password is
6601.
continued >
1
2
3
4. Press the
+
button (UNSWEET) to choose number.
5. Press the >>>> button (CONFIRM NEW BIB) to
move to next number.
Repeat steps 4 and 5 until all four digits are added.
6. Press
Done (SWEET).
The
SET LANGUAGE screen will appear.
8. Select
Yes
.
9. Place an empty measuring container under dilution
nozzle. Use the Coca-Cola Universal Measuring Cup
(CCP#12754) - This measurement is in milliliters (ml).
6
7. Press the right hidden button to advance to the
CALIBRATE SWEET screen.
NOTE:
This takes approximately 16 steps.
7
4
5
10. Display will say CONTAINER READY?.
Press
Yes (UNSWEET) button.
11. Display will show CAL FLOW SWEET 1.
Press
Yes (UNSWEET) button.
10
9
11
8