INITIAL FILL & HEAT

CAUTION

 - The dispenser must be disconnected from the power source throughout the initial set-up, except 

when specified in the instructions.
1.  Turn-on the water supply and connect the dispenser to the power source.

2.  Water will automatically flow into the tank to the proper level and then shut-off.  This will take less than five 

minutes. 

3.  When the tank is full of water, open the front door and place the heater switch in the “ON” (lower) position.  

A tank full of cold water will take approximately eighty minutes (IMIX-5S) or forty-five minutes (IMIX-3S) 

for the water to heat on 120 volt versions or forty minutes (IMIX-5S) or twenty-five minutes (IMIX-3S) for 

120/208 volt versions and 120/240 volt versions.

During this waiting period, complete these dispenser set-up steps:

a.  Place the drip tray in front of the dispenser.  Set the drip tray cover in place.

b.  Place a set of keyholes in the cup locator plate over the screws beneath the hopper access door and push 

down gently.

c.  Fill the hoppers with the dry product to be dispensed.

LIQUID LEVEL CONTROL

The system automatically maintains the hot water tank’s level by energizing the refill solenoid when the water 

level drops below the liquid level probe. If the system has not successfully refilled in 15 minutes, a refill error 

occurs. When a refill error occurs, the refill solenoid is de-energized and the left rinse L.E.D. will flash  about 

once every 5 seconds. Once the cause of the refill error has been investigated (see the troubleshooting guide in 

the Operating and Service Manual) and cured, the system can be reset by placing the Rinse/Run switch in the 

programming (center) position, momentarily.

RINSE TIMERS

The dispenser is shipped from the factory with the rinse timers disabled. To enable the rinse timers, remove 

power from the dispenser, remove the lower access panel, and remove the jumper from J1 of the control boards. 

Replace the lower access panel, and return power to the dispenser. When enabled,  the rinse timers automati-

cally keep track of the time since the dispenser was last run through a rinse sequence. If the dispenser detects 

that a rinse sequence has not been run for 8 hours, the appropriate rinse L.E.D. will flash continually.  If, after 

an additional 4 hours (12 hours total), a rinse sequence has still not been run,  the appropriate rinse L.E.D. will 

light continuously, and the appropriate hopper drives will be disabled until a rinse sequence has been run.

RUNNING A RINSE SEQUENCE

1.   Place the rinse/run switch in the rinse position.

2.   Sequentially, or simultaneously, at each of the positions dispense for at least 10 seconds.

3.   After the rinse L.E.D. has extinguished, the rinse timer is reset.

4.   Return the rinse/run switch to the run position.

DISPENSER USE

1.  Simply place a cup on the drip tray beneath the dispensing tip.

2.  Press the button and dispense the beverage.

3.  Release the button when the cup is approximately 3/4 full and allow the whipper chamber to drain.

NOTE

 -

 

The whipper chamber must drain at the end of each dispense.

36526 040706

Содержание iMIX-3S

Страница 1: ... IMIX 3S IMIX 5S 38526 0000C 09 07 2005 Bunn O Matic Corporation To obtain the Illustrated Parts Catalog visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to obtain the catalog Contact Bunn O Matic Corporation at 1 800 286 6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U S Postal Service ...

Страница 2: ... by such individuals whether oral or written do not constitute warranties and should not be relied upon If BUNN determines in its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or labor during the applicable parts and labor warranty periods specified abo...

Страница 3: ...he Basic Plumbing Code of the Building Officials and Code Administrators International Inc BOCA and the Food Service Sanitation Manual of the Food and Drug Administration FDA For models installed outside the U S A comply with the applicable Plumbing SanitationCode USER NOTICES The notices on this dispenser should be kept in good condition Replace unreadable or damaged labels 00831 0000 00656 0000 ...

Страница 4: ...er is disconnected from the power source If plumb ing has been hooked up the dispenser is ready for Initial Fill Heat PLUMBING REQUIREMENTS This dispenser must be connected to a COLD WATER system with operating pressure between 20 and 100 psi 138 and 690 kPa This water source must be capable of producing a minimum flow rate of 4 5 fl oz 133 1 ml per second A shut off valve should be installed in t...

Страница 5: ...ry 5 seconds Once the cause of the refill error has been investigated see the troubleshooting guide in the Operating and Service Manual and cured the system can be reset by placing the Rinse Run switch in the programming center position momentarily RINSE TIMERS The dispenser is shipped from the factory with the rinse timers disabled To enable the rinse timers remove power from the dispenser remove...

Страница 6: ...e rinse run switch to the run position after hopper motor speed adjustments are complete For IMIX 3S only 5 Once any of the three hopper motors has been programmed to the desired speed either or both of the other hopper motors can be set to the same speed as follows a Place the rinse run switch in the center program position b Press and hold the dispense switch that has been programmed for the cor...

Страница 7: ...7 ELECTRICAL WIRING DIAGRAM IMIX 3S 36526 040706 LEFT LAMP RIGHT LAMP ...

Страница 8: ...WHI GRN BLK BLU BLK WHI RED WHI BLK BLK WHI RED RED RED ORN YEL BLU BRN BLK BRN WHI RED WHI ORN WHI YEL WHI BLU GRN BLK RED WHI BLU RED BLK RED WHI WHI GRN BLU RED LAMP 1 BALLAST LAMP 2 BALLAST BLK BLK BLK BLK BLK BLK BLK BLK BRN BLK HOPPER 4 HOPPER 5 M M M SOL M SOL M SOL M SOL M SOL STATION 1 WHIPPER STATION 2 WHIPPER STATION 3 WHIPPER STATION 4 WHIPPER STATION 5 WHIPPER STATION 1 DISPENSE VALVE...