background image

12

Relay

Location:

The relay is located on the timer bracket in the

grinder base. The bracket can be removed by loosen-
ing the two 8-32 screws beneath the timer dial.

Test Procedure:
1.

Disconnect the grinder from the power supply.

2.

Check the voltage across the white/red and white/

green wires of the relay coil with a voltmeter when
the Off/On/Start switch is placed in the “START”
(right) position and released.  Connect grinder
to the power supply.  The indication must be:
(a)  120 volts ac for  two wire 120 volt models
(b)  240 volts ac for two wire 240 volt models
for the approximate setting on the timer.

3.

Disconnect the grinder from the power supply.

If voltage is present as described, reconnect the

white/red and white/green wires to the relay coil, and
proceed to step 4.

If voltage is not present as described, refer to the

Wiring Diagrams and check the grinder wiring har-
ness.

4.

Remove the white/red and white/blue wires from
the relay contacts.

5.

Check for continuity across the relay contacts
when the Off/On/Start switch is placed in the
“START” (right) position and released. Connect
grinder to the power supply. Continuity must be
present for the approximate setting on the timer.

6.

Disconnect the grinder from the power supply.

If continuity is present as described, reconnect

the white/red and white/blue wires, the relay is oper-
ating properly.

If continuity is not present as described, replace

the relay.

Removal and Replacement
1.

Remove all wires from the relay terminals.

2.

Remove the 6-32 screw fastening the relay to
the timer bracket.

3.

Mount the new relay to the timer bracket and
tighten the screw.

4.

Refer to the illustration below when reconnect-
ing the wires.

WHI/BLU to Motor L1

WHI/GRN to Timer L4

WHI/RED to Timer TL1

P610

MINU

TES

BU

NN-O-MATIC

P/N

 2620-   120 VAC

P1312

If continuity is not present as described, replace

the switch.

Removal and Replacement:
1.

Remove all the wires from the switch terminals.

2.

Compress the clips inside the housing and gen-
tly push the switch through the opening.

3.

Push the new switch into the opening and spead
the clips to hold the switch in the housing.

4.

Refer to the illustration below when reconnect-
ing the wires.

SERVICE (cont.)

TAN

PIN

YEL

ORA

GRN

P1318

Single set timer shown
Multi set timer (Urn/Carafe) similar

10171 121597

Содержание G9 HD

Страница 1: ...FAX 217 529 6644 10171 0000 5 00 1986 Bunn O Matic Corporation BUNN G9 HD G9T HD PE RS ON AL IN JU RY HA ZA RD KE EP FIN GE RS AN D FO RE IG N OB JE CT S OU T OF HO PP ER OR CH UT E OP EN ING CAUTIO...

Страница 2: ...d by Bunn or that in Bunn s judgement has been affected by misuse neglect alteration improper installation or operation improper mainte nance or repair damage or casualty THE FOREGOING WARRANTY IS EXC...

Страница 3: ...e entrance to the grind chamber 2 Fill hopper compartment with whole bean coffee Capacity 9 pounds The grinder is now ready for use OPERATING CONTROLS Off On Start Switch OFF left position Placing the...

Страница 4: ...can be set from very fine to very coarse The amount may be adjusted for use in most commercial coffee brewers The following procedures should be used to make adjustments A change in the burr adjustmen...

Страница 5: ...cover Timer Adjustment NOTE Grinders with Multi Set option Urn Carafe must be adjusted in both settings 1 Unplug the grinder and remove the lower front inspection panel 2 Determine the grind setting...

Страница 6: ...aution when servicing electrical equipment Turn power OFF when servicing except when electrical tests are specified Follow recommended service procedures Replace all protective shields or safety notic...

Страница 7: ...dures See page 12 Refer to Service Motor for testing procedures See page 9 A Place the switch in the OFF left position B Refer to Service Off On Start Switch for testing procedures See page 11 Refer t...

Страница 8: ...id removal The rear panel is attached with eight 8 32 screws The hopper extension assembly is attached with six 8 32 screws Contents Motor 9 Off On Start Switch 11 Urn Caraffe Switch 11 Relay 12 Timer...

Страница 9: ...plate 2 The entire wiring harness must be fed into the bottom of the grinder housing through the hole in the motor mounting plate 3 Remove both 6 32 screws beneath the upper front inspection panel 4...

Страница 10: ...amaged NOTE Burrs must be replaced as a set SERVICE cont Motor cont 11191 0001 COARSE FINE T H O R O U G HLYCLEAN GRIND CHAM B E R B E F O R E R E A S S E M B L Y E M P T YHOPPER BEFORE REM O V IN G T...

Страница 11: ...cribed replace the switch Removal and Replacement 1 Remove all wires from the switch terminals 2 Compress the clips inside the front wrapper and gently push the switch through the opening 3 Push the n...

Страница 12: ...START right position and released Connect grinder to the power supply Continuity must be present for the approximate setting on the timer 6 Disconnect the grinder from the power supply If continuity...

Страница 13: ...rness 6 Check the voltage across terminals TL1 and TL4 with a voltmeter when the Off On Start switch is placed in the START right position and re leased Connect grinder to the power supply The indicat...

Страница 14: ...WHI WHI WHI RED WHI RED OPTIONAL KEY SW 5 4 3 2 1 W H I O R A ORA URN CARAFE WHI GRN 1 BLK K1 WHI BLU M L2 L1 120 VOLTS AC 2 WIRE SINGLE PHASE 60 HZ 10215 0000C 4 97 1987 BUNN O MATIC CORPORATION L1 N...

Страница 15: ...HD TIMER WHI RED WHI YEL WHI ORA RED BLK RED BLK WHI RED WHI RED 5 4 3 2 1 10187 0001B 11 97 1997 BUNN O MATIC CORPORATION WHI GRN BLK K1 WHI BLU M L2 L1 200 VOLTS AC 2 WIRE SINGLE PHASE 50 HZ L1 L2...

Страница 16: ...RED GRY 1 2 OPTIONAL MULTI SET SW OPTIONAL BREWER INTERFACE CONNECTOR PNK TAN ORA PNK OPTIONAL KEY SW W H I O R A K1 M 120 VOLTS AC 2 WIRE SINGLE PHASE 60 HZ 4 3 WHI GRN 1 BLK WHI BLU M L2 L1 10388 0...