12
TROUBLESHOOTING (cont.)
PROBLEM
PROBABLE CAUSE
REMEDY
Water flows into tank continuously
(cont.)
Product overflows container
Weak product
3. Overflow Protection Switch
1. Digital Touch Control Switch
2. Dispense Solenoid Valve
(Hot or Cold)
3. Dispense time excessive
1. Water temperature
2. Whipper Motor
3. Frother
4. Dispense Solenoid Valve
(Hot or Cold)
5. Auger Drive
6. Auger Spring
Refer to
Service - Overflow
Protection Switch for testing
procedures. See page 33
Refer to
Service - Digital Touch
Control Switch for testing proce-
dures. See page 26
Remove the solenoid valve and
clear any obstructions. Rebuild or
replace the valve if necessary. See
page 35 or 36
Refer to
Dispense Run Time on
page 6
Place an empty container beneath
the dispense tip. Initiate a dispense
cycle and check the water tempera-
ture immediately below the dispense
tip with a thermometer.
(A) Reading for mechanical thermo-
stat models should be 180
°
F to 200
°
F
(see thermostat temperature settings
decal in
USER NOTICES on page 3.
(B) Reading for electronic thermo-
stat should be 185
°
F to 190
°
F.
Adjust the control thermostat to in-
crease or decrease the water tem-
perature. Replace if necessary.
Refer to
Service - Whipper Motor for
testing procedure. See page 28
Refer to
Service - Frother Compo-
nents. See page 28
Refer to
Service - Dispense Solenoid
Valve for test procedures. See page
35 or 36
Refer to
Service - Auger Drive Com-
ponents. See page 15
Refer to
Service - Auger Drive Com-
ponents. See page 15