Bunn DUAL SH DBC WITH SMART FUNNEL Скачать руководство пользователя страница 12

Page 12

PROGRAMMING THE BREWER (cont.)

RECIPE PROGRAMING METHODS

 

There  are  three  methods  of  programming  the 

various brewing parameters of the DUAL SH DBC with 

Smart Funnel Brewer.

METHOD 1:

Using  a  Smart  Funnel  and  a  G9-2T  DBC  or  MHG 

Grinder:

 

Certain coffee 

NAMES

 are stored in the G9-2T DBC 

or MHG's memory. When a particular name of coffee 

is ground into the Smart Funnel, that name and the 

batch size selected are transferred from the grinder to 

the programming 

chip 

located in the funnel's handle. 

The funnel is then inserted into the brewer's left side 

funnel rails. The sensor coil on the brewer reads the 

information contained in the handle. This then allows 

the  operator  to  set  the 

BREW  VOLUMES,  BYPASS 

PERCENTAGES, PULSE BREW TIMES, PREINFUSION 

TIMES 

and

 DRIP-OUT TIMES 

 for that particular coffee 

NAME

. Each coffee 

NAME

 can be set individually to 

provide optimum brewing quality.

METHOD 2:

Using a RECIPE CARD to enter all of the brew set-

tings at one time:

 

If using a coffee name not in the grinder's memory, 

the customer can obtain a 

RECIPE CARD 

from the 

factory with all the information needed to set up that 

particular  coffee  name.  This  includes  the 

COFFEE 

NAME

BREW VOLUMES, BYPASS PERCENTAGES, 

PULSE  BREW  TIMES,  PREINFUSION  TIMES, 

and 

DRIP-OUT TIMES.

METHOD 3:

Not using a Smart Funnel and/or a G9-2T DBC or 

MHG Grinder:

 

This allows the operator to enter 

ONE

 set of brewing 

parameters for each side, in the event a Smart Funnel 

and/or a G9-2T DBC or MHG  is not used with the Dual 

SH Brewer. This is referred to as a 

NO NAME

 coffee 

flavor. If the brewer does not read the information in 

the funnel's handle, it automatically selects the 

NO 

NAME 

brewing parameters set up prior to brewing. 

This includes 

BREW VOLUMES, BYPASS PERCENT-

AGES, PULSE BREW TIMES, PREINFUSION TIMES 

and

 DRIP-OUT TIMES 

for the three batch sizes. 

ARE YOU CREATING OR CHANGING A RECIPE FOR A

COFFEE NAME PREVIOUSLY USED IN THIS BREWER?

REFER TO NAME LIST

IN GRINDER MANUAL

CONTACT BUNN-O-MATIC

FOR ASSISTANCE

GO TO 

REVIEW RECIPES

AND FOLLOW INSTRUCTIONS

TO VIEW A LIST OF EXISTING RECIPES,

GO TO 

REVIEW RECIPES

AND FOLLOW THE INSTRUCTIONS

GO TO 

SET NEW RECIPE

,

AND FOLLOW THE

INSTRUCTIONS

YOU WILL ENTER

THE NO NAME LEFT

AND NO NAME

RIGHT BREW

SETTINGS

YOU WILL MODIFY AN

EXISTING RECIPE

DOES THE GRINDER HAVE THE

NAME IN ITS MEMORY?

FOLLOW INSTRUCTIONS

ON THE RECIPE CARD

HAVE YOU RECEIVED A RECIPE CARD

CONTAINING THE NEW RECIPE?

OR

OR

NO

NO

DON'T  KNOW

NO

YES

YES

YES

DON'T

KNOW

RECIPES

 

This diagram allows for the creating, modifying, 

or viewing of recipes in the brewer.

P2369

29877-3 062005

Содержание DUAL SH DBC WITH SMART FUNNEL

Страница 1: ...lutely FREE and the quickest way to obtain the catalog Contact Bunn O Matic Corporation at 1 800 286 6070 to obtain a paper copy of the required Illustrated Parts Catalog mailed via U S Postal Service...

Страница 2: ...he defective equipment is under warranty THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY WRITTEN OR ORAL EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY O...

Страница 3: ...Set New Recipe no Smart Funnel nor G9 2T DBC or MHG Grinder 20 Review Recipes Modify Recipes Set up No Name Coffee 21 Set Brew Volumes 22 Set Bypass Percentages 23 Set Pulse Brew Times 24 Easy Pulse 2...

Страница 4: ...This equipment must be installed to comply with the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Adminis tration FDA For models installe...

Страница 5: ...state and federal electrical codes 2 Using a voltmeter check the voltage and color coding of each conductor at the electrical source NOTE The brewer is shipped without a plug on the power cord Qualifi...

Страница 6: ...rating pressure between 20 and 90 psi 138 and 620 kPa from a 1 2 or larger supply line A shut off valve should be installed in the line before the brewer Install a regulator in the line when pressure...

Страница 7: ...ing this switch during the programming of the brewer will exit the setup and return to the main screen d BREW SWITCH Momentarily pressing and releasing this switch begins a brew cycle e PROGRAM SWITCH...

Страница 8: ...matically select the correct size to brew 5 Place an empty server under the funnel 6 The ENABLE BREW switch must be ON Momentarily press and release the BREW switch If the brewer has the funnel lock o...

Страница 9: ...set for the second on time and each alternating on time for the remainder of the brew cycle MAIN SCREEN The term used to describe the screen that is displayed when the brewer is not in use This scree...

Страница 10: ...s hidden programming switches are used There are five of these switches that will be used for the setup of the brewer 1 2 3 4 5 1 symbol upper right of the BUNN logo This is used to access the program...

Страница 11: ...temperature When finished press and release DONE This will exit this function screen and return to the MAIN SCREEN on the display PROGRAMMING THE BREWER The programming of the brewer is divided into t...

Страница 12: ...RCENTAGES PULSE BREW TIMES PREINFUSION TIMES and DRIP OUT TIMES METHOD 3 Not using a Smart Funnel and or a G9 2T DBC or MHG Grinder ThisallowstheoperatortoenterONEsetofbrewing parameters for each side...

Страница 13: ...T B Continue to C THAT WAS THE LAST RECIPE COPY SETTINGS NO YES LEFT RIGHT NO YES Continue to D Cycles thru right side program constants Cycles thru left side program constants Continue to E FULL 1 2...

Страница 14: ...A PROGRAM FLOW DIAGRAM Cont PROGRAMMING THE BREWER cont DONE 1st ON TIME X XX DONE OFF TIMES X XX DONE LAST ON Prel DONE 3 BATCHES DONE NO YES 1st OFF LAST X XX X XX PreI TRANSFER COMPLETE ENABLE ADS...

Страница 15: ...CK ON NEXT OFF LEFT SERVER ON NEXT OFF RIGHT BREW VALVE ON NEXT OFF RIGHT BYPASS ON NEXT OFF RIGHT FUNNEL LOCK ON NEXT OFF RIGHT SERVER ON NEXT OFF REFILL VALVE ON NEXT OFF HEATER CONTACTOR ON NEXT OF...

Страница 16: ...hisinformationstoredelsewhere so that the machine can be reprogrammed Procedure for modifying units of measure 1 Press and hold upper right hidden switch until the display reads UNITS Release switch P...

Страница 17: ...NAME can be set individually to provide optimum brewing quality PROGRAMMING THE BREWER cont 29877 3 062005 Procedure for Setting the Recipe NOTE Before beginning setup place a server beneath the left...

Страница 18: ...he setup instructions for SET TING PULSE BREW EASY PULSE 17 If setting pulse brew by ENTER TIMES entering known times press NO The display should read ENTERTIMES PressandreleaseYESandproceed 29877 3 0...

Страница 19: ...right funnel rails 2 Position the RECIPE CARD vertically so that the top end of the chip is beneath the left side funnel sensing coil 3 AfterashortpausethedisplaywillreadCARDCON TAINS RECIPE FOR then...

Страница 20: ...s BREW VOLUMES BYPASS PERCENTAGES PULSEBREWTIMES andDRIP OUT TIMES The brewer will perform in the same capacity as a standard BunnDual Brewer The instructions for programming the NO NAME settings are...

Страница 21: ...CTION SCREEN SCROLLS THROUGH ALL BREW SETTINGS FOR NO NAME LEFT COFFEE NAME SCROLLS THROUGH ALL BREW SETTINGS FOR ANY OTHER COFFEE NAMES STORED IN BREWER S MEMORY SCROLLS THROUGH ALL BREW SETTINGS FOR...

Страница 22: ...FFEE NAMES PROGRAMMED IN THE BREWER S MEMORY WHEN THE LAST COFFEE NAME IN THE BREWER S MEMORY IS DISPLAYED PRESSING NEXT WILL EXIT AND THE DISPLAY WILL THEN READ SEE MODIFYING BYPASS PERCENTAGES ON TH...

Страница 23: ...ANCES TO ALL OTHER COFFEE NAMES PROGRAMMED IN THE BREWER S MEMORY WHEN THE LAST COFFEE NAME IN THE BREWER S MEMORY IS DISPLAYED PRESSING NEXT WILL EXIT AND THE DISPLAY WILL THEN READ SEE MODIFYING PUL...

Страница 24: ...IL BREW CYCLE IS COMPLETED PRE INFUSION REMAINING ON ON TIME OFF TIME OFF TIME OFF TIME OFF TIME ON TIME ON TIME P2293 PROGRAMMING THE BREWER cont 29877 3 062005 Modifying pulse brew Range 1st on time...

Страница 25: ...LAST COFFEE NAME IN THE BREWER S MEMORY IS DISPLAYED PRESSING NEXT WILL EXIT AND THE DISPLAY WILL THEN READ See SET PULSE BREW EASY PULSE SETUP See SET PULSE BREW ENTER TIMES REVIEW RECIPES NO YES SET...

Страница 26: ...F LAST XX X XX X XX X EASY PULSE SETUP NO YES ENTER TIMES NO YES See SET PULSE BREW ENTER TIMES 3 When finished select another batch size to be set by pressing the switch next to the indicator light R...

Страница 27: ...ywillshow thethreetimesjustenteredforthatbatchsize After a 5 second delay the display will read 3 BATCHES DONE 10 If other batch sizes need to be modified press NO 12 Press a different batch size and...

Страница 28: ...into the funnel will be off 7 When finished press DONE The display will now read LAST ON PreI 8 If the display shows a time use and to set it to read PreI PreI is an abreviation for preinfu sion 9 Whe...

Страница 29: ...the and set the amount of time from when the brew solenoid shuts off to when drip out occurs for that batch size NOTE Set to OFF to prevent funnel locks from engag ing to disable this function for a p...

Страница 30: ...ess and hold the upper right hidden switch until thedisplayreadsUNITS Releasetheswitch Con tinue to press and release switch until the display reads COPY SETTINGS EXIT TO NEXT FUNCTION SCREEN COPY LEF...

Страница 31: ...is message will be displayed when the brewer is not in use P2721 Procedure to Enable Disable Ads 1 Press and hold upper right hidden switch until the display reads UNITS Release switch Continue to pre...

Страница 32: ...nces per minute Oz M P2721 Procedure to set ready temperature 1 Press and hold upper right hidden switch until the display reads UNITS Release switch Continue to press and release switch until the dis...

Страница 33: ...etting right side press and release DONE to advance to next function screen CALIBRATE FLOW Another alternative is to press and release either ON OFF switch located on the front switch panel to exit th...

Страница 34: ...REW COUNTERS 4 Press and release NO to advance to the BYPASS CALIBRATION screen 5 Press and release YES The display should read CONTAINER READY If the container is under the funnel press YES The displ...

Страница 35: ...RESET BREW COUNTERS NO YES Procedures to view reset the brew counters 1 Press and hold the upper right hidden switch until the display reads UNITS Release the switch Con tinue to press and release swi...

Страница 36: ...W COUNTERS function and return to the MAIN SCREEN FUNNEL DETECT optional This function allows the operator to prevent the start of a brew cycle if a Smart Funnel is not positioned correctly in the fun...

Страница 37: ...er EXIT TO NEXT FUNCTION SCREEN EXIT TO NEXT FUNCTION SCREEN PRESS AND RELEASE SYMBOL PRESS AND RELEASE SYMBOL PRESS AND RELEASE SYMBOL NEXT COMPONENT TO BE TESTED TEST OUTPUTS NO YES TEST SWITCHES NO...

Страница 38: ...ance to the next function Press YES in the TEST SWITCHES screen to test the switches The display will read NOTHING PRESSED 8 From this screen press any of the switches on the Procedure to test compone...

Страница 39: ...with arrows pointing to the left and right 8 Lift and pull both Soft Heat servers forward about 2 inches so that the two contacts on each server do not touch the two contacts on the brewer 9 The displ...

Страница 40: ...cetoFACTORY DEFAULTS Press and release YES The display should read ThermoF SoftHeat The selected brewer type will be flashing When correct brewer type is selected press DONE 3 ThedisplayshouldnowreadF...

Страница 41: ...a supply of water The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened This will help avoid twists and kinks in the tubing Make certain that all plumbing connect...

Страница 42: ...was started Positionthefunnelsothatthesensor isdirectlybeneaththesensorcoilon the brewer Disable the FUNNEL DETECT func tion a Wait for the brewer to heat to the proper temperature b Disable the BREW...

Страница 43: ...Failure 3 Control Board Thermistor failure To resume brewing correctly position the Soft Heat Server and press BREW again The brew cycle resumes from the point it was inter rupted OR PressON OFFtoter...

Страница 44: ...roken or not making connection 1 Temperature Sensor Probe wire s shorted to housing or to each other Check water supply shut off Service required Service required Check wire and connection of both bla...

Страница 45: ...er data plate within 10 Check plumbing and shut off valves Test the ON OFF switch Refer to the switch test procedures on pages 36 38 Test the BREW switch Refer to the switch test procedures on pages 3...

Страница 46: ...for extremewaterconditions verypure low conductance water requires a higher setting while high mineral content high conductance water requires a lower setting Note that the left number changes from a...

Страница 47: ...uching the refill probe to a low value when waterIStouchingtheprobe Forbest operation the right number should be set to a value midway between these low and high numbers Before changingthesetting conf...

Страница 48: ...r Connect a voltmeter across one of the tank heaters Reapply power to the brewer and refer to Testing Individual Components If the full supply voltage is measured when the tank heater is turned on and...

Страница 49: ...ndividual Components Turn the valve on for 30 seconds and collect thewaterdispensedfromthespray head Repeat the test several times to confirm a consistent volume of dispensed water If not consistent c...

Страница 50: ...f ground coffee in the funnel The BUNN paper filter should be centered in the funnel and the bed of ground coffee leveled by gentle shaking Empty the server remove its cover and place the server benea...

Страница 51: ...on or pulse brew Contact Bunn O Matic for sugges tions The nut on back of the solenoid must be tight or it will vibrate during operation Plumbinglinesshouldnotberesting on the counter top A The brewer...

Страница 52: ...76 0000D 01 07 2001 BUNN O MATIC CORPORATION 120 208 OR 120 240 VOLT A C GND SINGLE PHASE GRN N L1 BLK 14 RED 14 RED 14 RED 14 RED 14 RED 14 BLK 14 BLK 14 MODELS WITH MAIN ON OFF SWITCH ONLY WHI WHI L...

Страница 53: ...TABLE FUSE 24VDC LEFT SERVER TRANSFORMER RIGHT SERVER TRANSFORMER RECTIFIER AC AC 4 AMP RECTIFIER 24VDC CONTROL PC BOARD RIGHT FUNNEL SENSOR LEFT FUNNEL SENSOR VIO WHI VIO WHI YEL YEL J9 1 J9 5 J2 1 J...

Страница 54: ...SE 24VDC LEFT SERVER TRANSFORMER RIGHT SERVER TRANSFORMER RECTIFIER AC AC 4 AMP RECTIFIER 24VDC CONTROL PC BOARD RIGHT FUNNEL SENSOR LEFT FUNNEL SENSOR VIO WHI VIO WHI YEL YEL J9 1 J9 5 J2 1 J2 5 J2 1...

Отзывы: