background image

Page 9

ADJUSTMENTS & OPTIONAL SETTINGS

READY TO BREW

WATER TEMP: 200°

1

3

2

 

Using the menu-driven display on the front of the brewer, the operator has the ability to alter or modify various 

brewing parameters such as brew lockout, brew volume, brew strength, etc. This allows for the precise brewing 
of various fl avors of coffee.
 

Programming of the brewer is achieved by entering a certain function. Then, by the use of hidden programming 

switches, the operator can customize the brewing process to their specifi cations.

PROGRAMMING SWITCHES

1.   Function Screen

 

This is the display which shows the various functions.

2.  Right Hidden Switch

 

Press and hold to view the currently assigned recipe. Holding longer will enter "BrewWIZARD" programming 
mode and is also used to step forward through the menu.

3.  Left Hidden Switch

 

Press and hold to view ASSET NUMBER; press again to view SERIAL NUMBER. It's also used to step back-
wards through the program screens. 

4. "Digital"

 

This is used to select options that appear on the display during programming (NO/-)

 

"Brewer"

 (center under the display)

 

This is used to select options that appear on the display during programming (DONE/NEXT)

 

"Control"

 (lower right under the display)

 

This is used to select options that appear on the display during programming (YES/+)

4

39130.1 060810

Содержание Axiom-APS SERIES

Страница 1: ...the Operating Manual or to view the Illustrated Parts Catalog Programming Manual or Service Manual please visit the Bunn O Matic website at www bunn com This is absolutely FREE and the quickest way to...

Страница 2: ...its sole discretion that the equipment does not conform to the warranty BUNN at its exclusive option while the equipment is under warranty shall either 1 provide at no charge replacement parts and or...

Страница 3: ...servicing 03408 0002 03409 0002 12364 0000 00656 0001 As directed in the International Plumbing Code of the International Code Council and the Food Code Manual of the Food and Drug Administration FDA...

Страница 4: ...e switch to the appropriate position and replace the access panel DV Models Only 11 If plumbing is to be hooked up later be sure the brewer is disconnected from the power source If plumbing has been h...

Страница 5: ...At Least 90oC 194oF FOR USE ONLY ON AN INDIVIDUAL BRANCH CIRCUIT RATED 20 AMPS Dual Voltage Switch in 120V position Dual Voltage Switch in 120 208 240V position 120 208 120 240V AC Single phase models...

Страница 6: ...e brewer to clean the counter top Bunn O Matic does not recommend the use of a saddle valve to install the brewer The size and shape of the hole made in the supply line by this type of device may rest...

Страница 7: ...elected batch to brew Also used in programming to adjust settings on both batch sizes D MAIN ON OFF SWITCH This switch located on the left side of the brewer or rear panel turns power on and off to al...

Страница 8: ...It will help prevent liming problems in the brewer and takes less than a minute NOTE In the event that the Brew Logic circuit activates compensating for high lime build up it will temporarily disable...

Страница 9: ...Screen This is the display which shows the various functions 2 Right Hidden Switch Press and hold to view the currently assigned recipe Holding longer will enter BrewWIZARD programming mode and is al...

Страница 10: ...ORD 0 0 0 EXITING BrewWIZARD SELECT RECIPE NO YES PROGRAMMING FUNCTIONS FLOW CHART CONT BrewWIZARD ENTER SERVICE NO YES SET PASSWORD 0 0 0 ENTER SERIAL NO YES DRIP TIME 0 30 DONE SET PULSE BREW NO YES...

Страница 11: ...ONE YES EnableFreshTimer NO DONE YES ENABLE CLEAN NO DONE YES These two screens will change if BrewLogic is enabled SET READY 195 DONE ENTER ASSET NO YES SET LANGUAGE NO YES UNITS METRIC DONE ENG BREW...

Отзывы: