background image

SKU 94531        

 For technical questions, please call 1-800-444-3353 

PAGE 2

SPEcIFIcAtIONS

Electrical Requirements

AC Adapter Power Input: 120 VAC / 60 Hz

AC Adapter Power Output: 15 VDC

AC Adapter Type: Class II Transformer

AC Adapter Plug Type: 2-Prong (Non-Polarized)

AC Adapter Power Cord Type: 22 AWG x 2C x 6 Ft.

Camera Dimensions

4-1/2” W x 7-7/8” H x 2-1/4” Depth

Camera Specifications

Power Input: 15 VDC / Power Consumption: 10 Watts

380 Line Resolution / Six Infrared LED’s

13 Ft. (4m) Maximum Night Viewing

Call & Talk Push-Button Control

Monitor Dimensions

10-3/8” W x 8-3/8” H x 3” Mounting Depth (From the Wall) 

Monitor Specifications

4” CRT Diagonal (Flat Kinescope) / Black & White Screen

380 Line Resolution / Power Input: 15 VDC

Power Consumption: 10 Watts

Features

Auto-Off Operation (60± Seconds) / Built-In Infrared Night Vision

Outdoor Audio Limited (Inside Talking Cannot Be Heard by Caller, i.e., Mute Capable)

Up to 3 Indoor Monitors Possible on One Camera / Wire Camera Input

Button Controlled Door Opener (Requires Existing Electric Lock), Indoor Alarm Button

SAVE tHIS MANuAl

You will need this manual for the safety warnings and precautions, assembly, 

operating, inspection, maintenance and cleaning procedures, parts list and assembly 

diagram.  Keep your invoice with this manual.  Write the invoice number on the inside 

of the front cover.  Keep this manual and invoice in a safe and dry place for future refer-

ence.

gENERAl SAFEtY RulES

 WARNINg!  Read all instructions 

Failure to follow all instructions listed below may result in electric shock, 

fire, and/or serious injury.

SAVE THESE INSTRUCTIONS

grounded tools must be plugged into an outlet properly installed and 

grounded in accordance with all codes and ordinances.  Never modify the 

plug in any way.  Do not use any adapter plugs.  Check with a qualified 

electrician if you are in doubt as to whether the outlet is properly grounded.

  

If the product should electrically malfunction or break down, grounding provides a 

low resistance path to carry electricity away from the user.

Avoid body contact with grounded surfaces such as pipes, radiators, rang-

es, and refrigerators.  

There is an increased risk of electric shock if your body is 

grounded.

Do not expose electrically powered products to rain or wet conditions.  

Water entering an electrically powered product will increase the risk of electric 

shock.

Do not abuse the Power cord.

  

Never use the Power cord to pull the Ac 

Adapter from an outlet.  Keep the Power cord away from heat, oil, sharp 

1.

2.

3.

4.

REV 07b

Содержание 94531

Страница 1: ...s Blvd Camarillo CA 93011 Visit our website at http www harborfreight com Read this material before using this product Failure to do so can result in serious injury Save this manual Copyright 2006 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Fo...

Страница 2: ... inspection maintenance and cleaning procedures parts list and assembly diagram Keep your invoice with this manual Write the invoice number on the inside of the front cover Keep this manual and invoice in a safe and dry place for future refer ence GENERAL SAFETY RULES WARNING Read all instructions Failure to follow all instructions listed below may result in electric shock fire and or serious inju...

Страница 3: ...d nameplates on the Video Doorphone These carry im portant information If unreadable or missing contact Harbor Freight Tools for a replacement Wear ANSI approved safety impact eye goggles when assembling the Video Doorphone Using personal safety devices reduce the risk for injury Avoid accidental electrical shock Before attaching the Indoor and Outdoor Units to the walls check hidden areas within ...

Страница 4: ...Standard Asso ciation and the National Electrical Code See Outlets for 2 Prong Plug Double insulated tools may be used in either of the 120 volt outlets shown in the preceding illustration See Outlets for 2 Prong Plug Extension Cords Grounded tools require a three wire extension cord Double Insulated tools can use either a two or three wire extension cord As the distance from the supply outlet inc...

Страница 5: ...e suf fix W A W in Canada to indicate it is acceptable for outdoor use Make sure the extension cord is properly wired and in good electrical condition Always replace a damaged extension cord or have it repaired by a qualified elec trician before using it Protect the extension cords from sharp objects excessive heat and damp or wet areas RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS 120 240 VO...

Страница 6: ...ed to the inte rior wall preferably near a 120 volt grounded electrical outlet SCREW 5 WASHER 5 WALL ANCHOR 5 5 FT INDOOR UNIT MOUNTING PLATE 4 FIGURE C Position the Indoor Unit Mounting Plate 4 against the wall with its large rectan gular opening at top its four mounting prongs facing outward from the wall and at a height of five feet from the floor surface NOTE Make sure to use a leveling device...

Страница 7: ...t sunshine and rain Position the Outdoor Unit Mounting Plate 7 against the wall at a height of five feet from the floor ground surface NOTE Make sure to use a leveling device to ensure the Mounting Plate is straight and level against the wall See Figure D Using the two small openings in the Outdoor Unit Mounting Plate 7 as a tem plate mark the spots where two 1 8 diameter holes will be drilled in ...

Страница 8: ...n the spaces to avoid cutting into live electrical wires gas and water pipes See Assy Diagram Place the Outdoor Unit 11 in its Outdoor Unit Mounting Plate 7 and secure the Outdoor Unit to the Mounting Plate by tightening the two Screws 8 See Figure D and Assy Diagram Hang the Indoor Unit 1 on its Indoor Unit Mounting Plate 4 See Figure C and Assy Diagram Run the Telephone Cord 6 from the Outdoor U...

Страница 9: ...the visitor The visitor s image will disappear from the Monitor when you hang up the Hand set See Figure F An image of the visitor on the Monitor will last for one minute and then disap pear By pressing the Monitor Button on the Indoor Unit 1 the visitor s image will reappear for another sixty seconds or until you hang up the Headset See Figure F You must pick up the Handset on the Indoor Unit 1 t...

Страница 10: ...one is assembled but does not operate Make sure to press the Call Button on the Outdoor Unit Then press the Monitor Button on the Indoor Unit Check to make sure the AC Adapter is properly connected to the Indoor Unit Make sure the AC Adapter is properly connected to a working 120 volt grounded electrical outlet Make sure the Telephone Cord is properly connected from the Outdoor Unit to the Indoor ...

Страница 11: ...poses only and are not avail able individually as replacement parts PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY NEI THER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT IN F...

Страница 12: ...IC ELECTRONIC LOCK NOT INCLUDED SKU 94531 For technical questions please call 1 800 444 3353 PAGE 12 Note If connecting the Indoor Unit 1 to an electronic lock terminals C and D on the Indoor Unit must be connected with the electronic lock using RVV2 x 1 0mm2 or RVV2 x 1 5mm2 cord REV 07h ...

Отзывы: