The red main switch disconnects the machine from the power supply. We presuppose that the
safety fuses of the circuit and the residual current circuit are provided by the building's power supply.
After completion of work, the main switch should always be turned off.
Before all maintenance work on the machine (filling, emptying, cleaning, etc.) turn off machine and
pull the plug.
To avoid the risk of electric shock, do not remove the casing or open the back. There are no user
serviceable parts inside. Leave servicing to the experts! Keep this unit out of the rain and away from
moisture.
Pay attention to the warning signs on the machine. If you are not going to use the unit for some
time, remove the plug from the socket.
Avoid power peaks! Make sure heating and transport are switched off before turning on the unit. Set
speed down to 0.4m/min before using the reverse transport switch. Do not quickly repeat switching
on and off.
Water connection
After work or prolonged interruption, close the cock valve of the building's water supply to prevent
water damage from a possible leak in the hose.
Personal protection equipment
Do not touch heating elements and tubes. Danger of burn!
Rinsing water
The legislation generally prohibits to exceed certain maximum concentrations and quantities of cop-
per (and other heavy metals) in the waste water (usually 0.5 mg copper / liter of water). After brush-
ing the boards should not be rinsed under running water and do not dispose used rinsing water into
the sewer! Operate the rinsing water only either in a closed loop rinse or treat the rinse water with a
copper centrifuge or some special filter system. Metallic copper will be hardly removed in a ion ex -
changer system.
We recommend to use the water in the closed loop rinsing zone(s) as long as possible.
Collect used rinsing water and dispose the surplus together with the used chemicals.
Maintenance
The unit should only be maintained and repaired by qualified personnel. Never try to do more in the
way of maintenance to your unit than the operating instructions allow. Beyond that, always consult
an expert for repair work.
When changing the brush you must pay attention to the correct rotating direction of the brush.
For security reason, brushing rollers can only be activated if top cover is closed.
Attention: Do not start brush motor when brush is under load.
Bungard Elektronik GmbH & Co. KG, Rilkestraße 1, 51570 Windeck – Germany
Tel.: +49 2292 / 9 28 28-0, Fax: +49 2292 / 9 28 28-29