Bungard RLM 419P Скачать руководство пользователя страница 5

RLM419p-Manual-E

Page 5 / 13

 

The red main  switch disconnects  the machine  from  the power  supply.  We  presuppose  that  the
safety fuses of the circuit and the residual current circuit are provided by the building's power supply.
After completion of work, the main switch should always be turned off.
Before all maintenance work on the machine (filling, emptying, cleaning, etc.) turn off machine and
pull the plug.
To avoid the risk of electric shock, do not remove the casing or open the back. There are no user
serviceable parts inside. Leave servicing to the experts! Keep this unit out of the rain and away from
moisture.
Pay attention to the warning signs on the machine. If you are not going to use the unit for some
time, remove the plug from the socket.
Avoid power peaks! Make sure heating and transport are switched off before turning on the unit. Set
speed down to 0.4m/min before using the reverse transport switch. Do not quickly repeat switching
on and off.

Water connection

After work or prolonged interruption, close the cock valve of the building's water supply to prevent
water damage from a possible leak in the hose. 

Personal protection equipment

Do not touch heating elements and tubes. Danger of burn!

Rinsing water

The legislation generally prohibits to exceed certain maximum concentrations and quantities of cop-
per (and other heavy metals) in the waste water (usually 0.5 mg copper / liter of water). After brush-
ing the boards should not be rinsed under running water and do not dispose used rinsing water into
the sewer! Operate the rinsing water only either in a closed loop rinse or treat the rinse water with a
copper centrifuge or some special filter system. Metallic copper will be hardly removed in a ion ex -
changer system.
We recommend to use the water in the closed loop rinsing zone(s) as long as possible.
Collect used rinsing water and dispose the surplus together with the used chemicals.

Maintenance

The unit should only be maintained and repaired by qualified personnel. Never try to do more in the
way of maintenance to your unit than the operating instructions allow. Beyond that, always consult
an expert for repair work.
When changing the brush you must pay attention to the correct rotating direction of the brush.
For security reason, brushing rollers can only be activated if  top cover is closed.
Attention: Do not start brush motor when brush is under load.

Bungard Elektronik GmbH & Co. KG, Rilkestraße 1, 51570 Windeck – Germany

Tel.: +49 2292 / 9 28 28-0, Fax: +49 2292 / 9 28 28-29

, E-mail: [email protected]

Содержание RLM 419P

Страница 1: ... Use of Machine 4 Safety Instructions 4 Short instructions 6 Operating 7 Service and Maintenance 10 Spare part list 11 Guarantee 13 Disclaimer of Warranty 13 Copyright 13 Bungard Elektronik GmbH Co KG Rilkestraße 1 51570 Windeck Germany Tel 49 2292 9 28 28 0 Fax 49 2292 9 28 28 29 E mail support bungard de ...

Страница 2: ...l Easy and fast mounting of resist rollers of nearly all coil diameters Detachable inlet table for easy access to low resist roll step less adjustable laminating speed digitally adjustable roller temperature with actual and set point display and programmed control be haviour starting 2012 Reverse drive for transport Technical Data Lamination width max 400 mm Transport width max 440 mm Lamination s...

Страница 3: ... Maschinen Teil 1 Allgemei ne Anforderungen Safety of machinery Electrical equipment of machines Part 1 General require ments DIN EN ISO 14121 1 Sicherheit von Maschinen Risikobeurteilung Teil 1 Leitsätze Safety of ma chinery Risk assessment Part 1 Principles DIN EN ISO 12100 1 Sicherheit von Maschinen Allgemeine Gestaltungsleitsätze Risikobeurteilung und Risikominderung Safety of machinery Basic ...

Страница 4: ...be standing level and around the machine there has to be sufficient space for operation and maintenance work approx 1m on all sides Do not place the unit in a location near heat sources such as radiators hot air ducts furnace and the like The laminator should be installed on a table where you have access to the front and rear side of the unit Special care must be taken to avoid any UV light emissi...

Страница 5: ...ouch heating elements and tubes Danger of burn Rinsing water The legislation generally prohibits to exceed certain maximum concentrations and quantities of cop per and other heavy metals in the waste water usually 0 5 mg copper liter of water After brush ing the boards should not be rinsed under running water and do not dispose used rinsing water into the sewer Operate the rinsing water only eithe...

Страница 6: ...pears on the controller display After some seconds the actual and the target temperature are displayed Turn on the transport and check the speed of adjustment Turn the heating on and control that the heating rolls warm up and the actual temperature increases in the display Caution Danger of burns You can adjust the target temperature by pressing the C key and then use the arrow keys to adjust the ...

Страница 7: ...plication If the temperature is too low the resist will not stick to the copper if it is too hot the material develops vapours that could irritate your nose and throat and the resist could lose its sensitivity to light or could be otherwise damaged The speed setting depends on the thermal conductivity of the ma terial you want to laminate As a starting value for your own tests we recommend a setti...

Страница 8: ...n Mount the right flanges and push them onto the coil as far as possible The coils must not slip on the flanges If the coils slip on the flanges the separation foil might get between the heating rollers Mount the coil holders back to the laminator and put the take up rollers back in their place The laminate consists of three layers These are the outer strong and transparent polyester cover foil th...

Страница 9: ... transport Keep tension on the hand wheel until you feel that the transport rollers grab the cardboard Stop the transport before the cardboard disappears completely between the heating rollers Check that upper and lower laminate run congruent If necessary loosen alternately the left and right upper flange and move these rollers till the laminate aligns properly If the laminate shows wrinkles after...

Страница 10: ...ow the side walls had to be removed and the rollers taken out From year 2012 the RLM 419p is equipped with a Re verse drive for transport button Thus the laminate can be easily re moved from the laminator The Reverse drive for transport button should only be used for this purpose Avoid power peaks Set speed down to 0 4m min before using the reverse transport switch Do not quickly repeat switching ...

Страница 11: ...9p laminat fixation 680168 Auslauftisch Laminator RLM 419p rear table for RLM 419p laminator 6000 Einlauftisch Laminator RLM 419p Front table for RLM 419p laminator 680170 Gelblicht UV Filterfolie Breite 1 2m Zuschnitt von UV filter foil yellow cut from roll width 1 2m price 680171 Gelblicht UV Filterhülle für Leucht stoffröhren UV filter sleeve yellow 1 2m lenght 680175 Entschäumer für Entwickler...

Страница 12: ...nt bis 2011 Temp sensor Thermoelement till 2011 LM571601 O Ringe Transport O rings transport LM571602 O Ringe Jumbo O rings Jumbo 699304 Schalter beleuchtet f RLM Switch illuminated Main switch with relay Power cord with plug 60000 Anti Statik Bürste Anti static brush 60000 Anschlag für Einlauftisch Parallel stop for inlet table 60000 Vorspannungsfeder für die Heizwalzen Spring for heat rollers 60...

Страница 13: ...to transport stocking setup installation and service of the machine Unlicensed modifications at the machine Incorrect or incomplete repairs Destructive force effect at the machine in cause of foreign objects or external use of force Use of non original spare parts normal wear parts We cannot accept subsequent claims from damage or destruction of work pieces worked on in the ma chine because we hav...

Отзывы: