rdc-30-manual-en
Page 8 /
Screen # Description
Display
16
Having clicked
1
in screen 15 you can adjust the dipping depth.
This menu has two screens. One for the distance drive from vir-
tual end switch to point of speed change and one for the dip
drive (point of speed change to bottom point dip) First you set
the distance drive. Please insert at least 50 mm. The maximum
drive is limited to 1000 mm, but keep in mind our remark at the
beginning of chapter
Operating
.
When you press
C
, the screen changes to edit mode. You can
enter your desired distance and confirm with
Enter
. You will
automatically go to:
17
Set distance dip. The menu has the same structure as the dis-
tance drive. Pressing
C
this screen changes into edit mode and
you can insert your desired distance. With
Enter
you return to
screen 14.
18
Having clicked
2
in screen 15 you can adjust the descending
speed. This menu has also 2 screens. First you can adjust the
speed for the distance drive. Press
C
to change screen into edit
mode. Insert your desired speed. With
Enter
you go automatic-
ally to screen Speed down dip.
19
The Speeddown dip mene works the same as the Distance
menu before. Press
C
to get into edit mode. Insert your desired
speed between 3 mm/min and 2500 mm/min. You can correct
your input with
CE
. Confirm with Enter to go back to screen 14.
20
Having clicked 3 in screen 15 you can adjust the ascending
speed. This menu works the same as screen18 and 19. With
Enter you confirm the values and return to screen 14.
21
Having clicked
4
in screen 15 you get an overview on all set-
tings adjusted to the current table position. In the first screen
you can see the settings for the distance drive. If you press
8
,
another screen with the settings for the dip drive shows up. With
8
you can switch between the two screens, with
9
you go back
to screen 14. Please check carefully, if all settings are correct,
before starting the dipping procedure. “
it
” in these screens
stands for iterations for this drive, whereas “
Itg
” means the
number of iterations for the whole job.
distance
distance: ___mm
Change=C or OK=Enter
Min. 50/max. 1000mm
1.pos.1
5.pos.5
2.pos.2
6.pos.6
3.pos.3
7.back
4.pos.4
Speeddown distance
6500 mm/min
____________
(min.3 / max 7000)
Speedup distance
____ mm/min
Change=C or OK=Enter
(min.3 / max 7000)
Bungard Elektronik GmbH & Co. KG, Rilkestraße 1, 51570 Windeck – Germany
Tel.: +49 (0) 2292/9 28 28 - 0, Fax: +49 (0) 2292/9 28 28 - 29, E-mail: [email protected]
Distance dip
distance: ___mm
Change=C or OK=Enter
Min. 50/max. 1000mm
distance
distance: ___mm
_____
Min. 50/max. 1000mm
Speeddown distance
6500 mm/min
Change=C or OK=Enter
(min.3 / max 7000)
Speeddown dip
200 mm/min
________
(min.3 / max. 2500)
Speedup dip
____ mm/min
Change=C or OK=Enter
(min.3 / max 2500)
Vdis.u=6000 dist=50
Vdis.d=5000 it=1
Timer up=00:00:09
Itg=1
I->=8 esc=9
Vdip.u=300 dip=10
Vdip.d=200 it=1
Timer d=00:00:05
Itg=1
I->=8 esc=9