background image

Page 18

1062DOC  Rev C

Effective date: 6-Mar-14

User Guide 

RAMVAC Bulldog

®

 QT

RAMVAC

®

 Product Support Services

The DentalEZ Group and its employees are proud of the products we provide to the dental community. We stand behind these products with a 

warranty against defects in material and workmanship as provided below.

In the event that you experience difficulty with the application or operation of any of our products, please contact our customer service department 

at our expense at (866) DTE-INFO.

If we cannot resolve the issue by telephone, we will arrange for a representative to contact you or suggest that the product be returned to our fac

-

tory for inspection.

If product return or repair is required, we will provide you with a Return Authorization number and shipping instructions to return the product to 

the proper facility. If the product is under warranty we will ask you to provide proof of purchase such as a copy of your invoice. Please be sure to 

include the Return Authorization number on the package you are returning. Products returned without a return authorization number cannot 

be repaired.  

Freight costs for product returns are the responsibility of the customer. Products under warranty will be repaired or replaced, at our sole discretion, 

and returned at our expense. Products outside the warranty limits will be repaired and returned with costs invoiced to the customer. We are not 

responsible for shipping damages. We will, however, help you file a claim with the freight carrier. Written repair estimates are available. 

DentalEZ warrants all equipment and parts to be free of defects in material and workmanship, under normal usage, under the following terms:

 

RAMVAC Products: 

Warranty Period:

 RAMVAC

®

 Dental Vacuum System 

2 Years from date of installation*

 RAMVAC

®

 Vacuum Pumps only 

10 Years from date of installation*

 RAMVAC

®

 OWL

 

2 Years from date of installation*

 CustomAir

®

by RAMVAC®

 

6 Years / 4200 hours from date of installation*   

Please note the following additional terms of our warranty and return policy:

 

•  Warranties cover manufacturing defects only and do not cover defects resulting from abuse, improper handling, cleaning, care or

 

 

maintenance, normal wear and tear or non-observance of operating, maintenance or installation instructions.  Failure to use

 

 

authorized parts or an authorized repair facility voids this warranty.

 

•  Liability is limited to repair or replacement of the defective product at our sole discretion. All other liabilities, in particular

 

 

liability for damages, including, without limitation, consequential or incidental damages are excluded.

 

•  This warranty is in lieu of all other warranties, expressed or implied, including ANY IMPLIED warranties of merchantability or

 

 

fitness for a particular purpose. no employee, representative or dealer is authorized to change this warranty in any way or to

 

 

grant any other warranty.

WARRANTY REPAIRS:

Parts repaired or replaced on a product that is in warranty will be warranteed for the duration of that product’s original warranty.

NON-WARRANTY REPAIRS:

The warranty on parts either repaired or replaced on an out-of-warranty product will cover the repaired part only and will be for the timeframe of a 

new parts warranty period.

PRODUCT RETURN:

Opened products or product returns more than a year old cannot be returned for credit. There will be a 15% ($25.00 minimum) restocking charge 

on all items authorized for return.  

*When installed, operated and maintained in accordance with written instructions.

RAMVAC, Bison, Bulldog, FLOWCHECK, Ramclean and VACHECK are registered trademarks and InfiniTank, OWL and SlugBuster are trademark of RAMVAC Dental Products, Inc.

Содержание RAMVAC Bulldog QT

Страница 1: ...OPERATION MAINTENANCE AND USER MANUAL DENTAL VACUUM SYSTEM...

Страница 2: ...s and Cautions Thank you for selecting RAMVAC to serve your dental facility RAMVAC provides industry leading technology for convienient and efficient utility room equipment Invest a few minutes of you...

Страница 3: ...l concentrations typically encountered in dental analgesia The additional air drawn into a properly installed and operated Vacuum Unit will dilute these agents Never use your RAMVAC to remove pure nit...

Страница 4: ...N Guidance and manufacturer s declaration electromagnetic immunity The Bulldog is intended for use in the electromagnetic environment specified below The customer or the user of the Bulldog should ass...

Страница 5: ...tromagnetic environment guidance Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 Vrms 150 kHz to 80 MHz 3 V m 80 MHz to 2 5 GHz Does Not Comply Does Not Comply Portable and mobile RF communicat...

Страница 6: ...9 Maintenance Maintenance Overview Page 10 Preventive Maintenance Schedule Page 10 Oil Fill Level Page 10 Cleaning the Vacuum System Page 11 Air Filters Page 11 Lubrication System Components Page 12 O...

Страница 7: ...ays or be otherwise suitable for motor circuit 3 Disconnect must be fusible and sized per UL 98 UL 489 or UL 508 Must be supplied and installed by a licensed electrician 4 Motors are NEMA rated Electr...

Страница 8: ...Page 8 1062DOC Rev C Effective date 6 Mar 14 User Guide RAMVAC Bulldog QT MOTOR L1 MOTOR L2 LINE IN L1 LINE IN L2 GROUND Electrical Connection S2 Logic Board...

Страница 9: ...chematic Gases Continue To Pump Facility Vacuum Piping Separating Tank Liquids and Solids Drain When Vacuum is off Bulldog Vacuum Unit Power To Motor Exhaust To Outside Weather Cap Required Remote Con...

Страница 10: ...ally Remote switch indicator will flash slowly S2 and or OWL Touch will indicate maintenance is due on the display Perform Preventative Maintenance Hold reset button until it resets Moisture in Filtro...

Страница 11: ...1 000 hours Check Air Filters See Air Filters Check Drip Rate See Check Oil Drip Rate Every 2 000 hours Change Oil and check oil filter See Oil Change Check V Belt See Check V Belt The S2 will display...

Страница 12: ...unces of an appropriate vacuum line cleaner such as SlugBuster through the lines For overhead plumbing be sure to allow air to follow liquids before closing vacuum valves Clean treatment room solids s...

Страница 13: ...is its Lubrication System The Lubrication System supplies oil drop by drop through Drippers to the pump Used oil is discharged back into the Oil Reservoir as a mist separated from the exhaust filtered...

Страница 14: ...ip rate See Check Oil Drip Rate Dispose of used oil at a gas station or lubricant recycling station 4 Reset Change Oil From Change Oil screen press and hold the reset button for 5 seconds Check Oil Dr...

Страница 15: ...trol Terminals Toggle Switch or other non illuminated switch option Air Switch Air Light Common F 24 VDC G 24 VDC H DC Common Illuminated Remote Switch Note Maximum wire length for low voltage 18 gaug...

Страница 16: ...sture Allow the Separating Tank to drain Lift off the Vacuum Controller remove Main Air Filter Clean out any remaining moisture Remove Moisture Sensor by twisting and pulling down and dry contacts See...

Страница 17: ...nt Temperature Dirty Oil Filter Improper Oil Raise ambient temperature Clean Filter Change to recommended oil Drip Rate Fast High Ambient Temperature High Vacuum Pressure Improper Oil Lower ambient te...

Страница 18: ...RAMVAC Dental Vacuum System 2 Years from date of installation RAMVAC Vacuum Pumps only 10 Years from date of installation RAMVAC OWL 2 Years from date of installation CustomAir by RAMVAC 6 Years 4200...

Страница 19: ...Page 19 1062DOC Rev C Effective date 6 Mar 14 RAMVAC Bulldog QT User Guide...

Страница 20: ...www dentalez com www ramvac com 1062DOC Rev D Effective date 6 May 17 2012 RAMVAC Dental Products All rights reserved No part of this publication may be copied or distributed transmitted or transcrib...

Отзывы: