TACSIGHT SE35™ Thermal Imager
User Manual
Loading/Unloading the Battery
Loading and unloading the battery on the TacSight SE35 is easy
(Figure 4)
.
To install a battery, slide the battery into the groove on the bottom of the unit
and ensure that the battery is properly seated. To remove a battery, depress
both battery locking buttons simultaneously and slide the battery out of the
unit. Since it can only be loaded one way, the battery is easily replaced in the
dark.
Additionally, as with all batteries, your rechargeable battery will experience
a slow drain of its charge during storage. The amount of drain varies widely
based on storage conditions. For best performance, charge each of your
batteries every week. A fully charged battery should provide approximately
90 minutes of operating time. This may be affected by storage
temperatures, storage time and the age of the battery.
The approximate battery level is indicated by the colored LED lights on the
top of the display screen. When the red LED light is lit, the battery has
approximately 8 minutes of ooperation time remaining.
NOTE
Bullard provides an optional AA alkaline battery case which can
be used as an alternative to the standard 10 volt NiMH
rechargeable batteries. The AA alkaline battery case requires
eight AA alkaline batteries. Once the batteries are installed, the
case loads into the unit in the same manner as the standard
NiMH battery.
Due to the unique way that alkaline batteries disperse power to
the thermal imager, the LED indicators will report battery levels
that are not necessarily indicative of the battery’s actual
remaining charge.
Do not attempt to place the alkaline battery case into a TacSight SE35 battery
charger.
Side Straps
The side straps are designed to be field replaceable. Users can order
replacements and install them without having to return the thermal imager
to the factory. To adjust a side strap, loosen the hook and loop material on
the inside of the strap and set it to the desired length. Then press the hook
and loop material together.
Removing/Installing the Side Straps
To remove either of the right or left side straps, loosen the hook and loop
material on the inside of the strap and remove the strap from the plastic
loop located on either side of the LCD display
(Figure 5)
. Remove the
screw that holds the strap to the imager. To install, fasten the strap to the
unit using the screw provided. Feed the strap through the strap loop and
adjust to the desired length.
Care Instructions
The TacSight SE35 Thermal Imager requires very little
maintenance.
For best results, after each use:
• Clean the outside of the unit with mild soap or detergent.
• Wipe the lens with a soft cloth.
• Clean the display with a soft cloth.
• Check screw tightness on side straps.
• Store your TacSight SE35 in the rugged hard case.
Bullard also provides preventive maintenance programs for all of
its thermal imagers. Consult with your distributor regarding
availability and recommendations.
Cleaning the Lens
The TacSight SE35 lens is recessed in an impact resistant bezel. The
lens can be cleaned with a soft cloth and soapy water as required.
Replacing the Video Display Cover Window
The display cover has a scratch resistant hard coating to minimize
marring. However, if heavy scratching or gouging does occur, the
cover window can be replaced. To do this, simply remove the four
screws along the top and bottom of the window. Remove the plastic
display cover window and replace with a new one making sure that
the countersink slots around the mounting holes are facing
outward. Replace the mounting screws and tighten them; avoid
over-tightening the screws.
Service
If your thermal imager is not functioning properly, contact Bullard
Customer Service at 1-877-BULLARD. A customer service
representative will work with you to determine if the problem can
be solved in the field, or if the thermal imager must be returned to
the Bullard Service Center. If the thermal imager will be returned
to Bullard, please ensure that:
1. You have indicated the Return Authorization number on the
package;
2. Your thermal imager is not contaminated by hazardous
materials;
3. You package the thermal imager carefully, preferably in its
original case;
4. You send all applicable accessories as requested by the
customer service representative;
5. You ship the package with freight prepaid.
Qualified warranty repairs will be handled promptly at no charge to
the user. Non-warranty repairs will be evaluated and quoted based
on the Service Center program in place at the time. Non-warranty
evaluations and repairs may be subject to evaluation fees.
CAUTION
Do not use solvents or paint thinners to clean your TacSight
SE35 Thermal Imager as they could permanently mar the
surface or degrade the properties of the outer shell. Failure to
observe this instruction may result in equipment damage.
CAUTION
The TacSight SE35 Thermal Imager should not be stored in sub-
freezing environments. Failure to observe this instruction may
result in equipment damage.