background image

www.bullard.com

5

Br

eathing Air Pr

essur

e  T
able

RT Series Respirator Hood

User Manual for use with supplied air respirators

RT Breathing Air Pressure Table

Special or Critical User’s Instructions

This table defines the air pressure ranges necessary to provide CC20 Series respirators with a volume of air that falls within the required range of 6-15 cfm or 170-425 lpm according to U.S. Government 
regulations (42 CFR, Part 84, Subpart J, 84.150, Table 8).

1

2

3

4

5

6

Air Source

Flow Control Valve/ 

Climate Control Device

Air Supply Hose

Air Supply Hose 

Length (feet)

Maximum Number of 

Hose Sections

Required Pressure 

Range (psig air)

Stationary or Portable Air 
Compressor

F30, F30B, F30S, F31, F32, 
F33,  F34

V10

25
50

75-150

200

250-300

1
2
3
5
5

14-15
15-18
19-29
25-34
31-39

F40, F40B, F40S, F41, F42, 
F43, F44

V10

25
50

75-150

200

250-300

1
2
3
5
5

22-25
24-27
27-37
33-40
38-45

V5

25
50

1
2

22-26
25-30

AC100030, AC100030B, 
AC100030S, AC100031, 
AC100032, AC100033, 
AC100034

V10

25-50

75-150

175-300

2
3
5

55-65
60-70
65-75

V5

25
50

1
1

55-65
56-69

DC5040, DC5040B, DC5040S, 
DC5041, DC5042, DC5043, 
DC5044

V10

50

75-150

200
250
300

2
3
3
3
5

52-54
59-72
80-84
85-92
90-98

V5

25
50

1
2

53-57
67-71

HC2400030, HC2400030B, 
HC2400030S, HC2400031, 
HC2400032, HC2400033, 
HC2400034

V10

25
50

75-150

200
250
300

1
2
3
4
5
5

59-61
63-65
68-75
77-79
80-82
84-86

V5

25
50

1
1

65-66
68-69

Bullard Free-Air

®

 Pumps

F35, F35b, F35s

V20

50

100
200
300

1
2
2
3

4-6
6-8

10-15
13-18

Frigitron 2000
Frigitron 200B
Frigitron 2000S

V20

50

100
200
300

1
2
2
3

16-22
18-25
22-30
25-34

Содержание RT Series

Страница 1: ...ard offers the appropriate approved breathing tube flow control device and air supply hose to connect the RT Series respirator to these breathing air sources RT Series respirators are approved by NIOSH for use with optional Bullard climate control devices Contact Bullard or our local authorized distributor for more information about these and other accessories for RT Series respirators All Bullard...

Страница 2: ...r critical User s Instructions and or specific use limitations apply Refer to User s Instructions before donning 2 CAUTIONS AND LIMITATIONS CF CONTINUOUS FLOW SA SUPPLIED AIR 1 PROTECTION TC PROTECTION1 MODEL ALTERNATE HOOD A SSEMBLIES ALTERNATE BREATHING TUBES ALTERNATE FLOW CONTROL DEVICES ALTERNATE AIR SUPPLY HOSES ACCESSORIES CAUTIONS LIMITATIONS2 RT SERIES HOODS RT1 RT2 RT3 RT4 20BT RTBT HC24...

Страница 3: ...irator Hood User Manual for use with supplied air respirators Respirator Hood Clamp BreathingTube Inner bib Clamp Flow Control Device Belt Air Supply Hose Fig 1 Clean Breathable Air Source Supplying Grade D or Higher Air Quality See Breath ing Air Requirements on page 4 Flow Control Device Without Climate Control Devices With Climate Control Devices Cold Only Hot Cold Adjustable Constant P A R T N...

Страница 4: ...ains contaminant free Always use an inlet filter on your air source Use suitable after cooler dryers with filters and carbon monoxide monitors and alarms as necessary to assure clean breathable air at all times Compressed air should be regularly sampled to be sure that it meets Grade D requirements RT Series Respirator Breathing Air Pressure Air pressure should be monitored at the point of attachm...

Страница 5: ...r F30 F30B F30S F31 F32 F33 F34 V10 25 50 75 150 200 250 300 1 2 3 5 5 14 15 15 18 19 29 25 34 31 39 F40 F40B F40S F41 F42 F43 F44 V10 25 50 75 150 200 250 300 1 2 3 5 5 22 25 24 27 27 37 33 40 38 45 V5 25 50 1 2 22 26 25 30 AC100030 AC100030B AC100030S AC100031 AC100032 AC100033 AC100034 V10 25 50 75 150 175 300 2 3 5 55 65 60 70 65 75 V5 25 50 1 1 55 65 56 69 DC5040 DC5040B DC5040S DC5041 DC5042...

Страница 6: ...ngth This cannot be done for the 20BT breathing tube To do this first determine how much shorter you need to make the tube The tube cannot be shortened more than 6 inches Mark a line with a marker pen where you want to make the cut Take a sharp cutting instrument and cut through the breathing tube and foam inside Be careful not to damage the remaining tube or foam If this does occur replacement wi...

Страница 7: ...r the top of the lens that allows the user to customize the curvature of the lens to his her personal preference This strap may be removed if desired 5 Make sure that the breathing tube is not twisted after donning 6 Tuck inner bib of hood into shirt or protective clothing for additional splash and overspray protection see Figure 9 7 Pull respirator outer bib over collar of shirt or protective clo...

Страница 8: ...ce Cleaning Bullard does not recommend laundering the hood When the hood becomes dirty it should be discarded and replaced The respirator s plastic lens should be hand sponged with warm water and mild detergent rinsed and air dried After cleaning and before reassembling once again carefully inspect parts for signs of damage 8 Inspection Cleaning and Storage WARNING Failure to heed these instructio...

Страница 9: ...ghtly to the hose so that no air can escape Make sure the hose has not been kinked or crushed by any equipment that may have rolled over it If any of the above signs are present or any other signs of excessive wear are detected replace the hose s immediately or remove the respirator from service Cleaning The air supply hose s should be hand sponged with warm water and mild detergent rinsed and air...

Страница 10: ...available F35 Constant flow control valve with 1 2 Industrial Interchange Hansen compatible quick disconnect nipple Climate Control Assemblies for RT Series Airline Respirators For use with Breathing Air Compressors Cold Tubes Adjustable Flow AC100030 With 1 4 Industrial Interchange steel Hansen compatible quick disconnect nipple AC100031 With 1 4 Schrader steel quick disconnect nipple AC100032 Wi...

Страница 11: ...5KF5032XXX 50 15 2 m with 1 4 Snap Tite steel fittings V5KF2533XXX 25 7 6m with 1 4 Snap Tite brass fittings V5KF5033XXX 50 15 2 m with 1 4 Snap Tite brass fittings V5KF2533XXXFF 25 7 6m with 1 4 Snap Tite brass fittings V5KF5033XXXFF 50 15 2 m with 1 4 Snap Tite brass fittings V5KF2533XXXFS 25 7 6m with 1 4 Snap Tite brass fittings V5KF5033XXXFS 50 15 2 m with 1 4 Snap Tite brass fittings V5KF253...

Страница 12: ...ht collect basis 5 Returned products will be inspected upon return to the Bullard facility Bullard Customer Service will telephone you with a quote for required repair work which is not covered by warranty If the cost of repairs exceeds stated quote by more than 20 your Customer Service specialist will call you for authorization to complete repairs After repairs are completed and the goods have be...

Отзывы: