background image

www.bullard.com

10

NIOSH Label

PA30IS Appr

ov

al Label

PA30IS P

ow

er

ed Air-Purifying Respir

ator

This r

espir

ator is appr

ov

ed only in the f

ollo

wing configur

ations:

Bullar

d

Cynthiana, KY 41031 US

A

1-800-827-0423

A. Not f

or use in atmospheres containing less th

an 19.5% o

xygen.

B. Not f

or use in atmospheres immediatel

y dangerous to lif

e or health.

C. Do not exceed maximum use concentrations established b

y regulatory standards.

F.  

 Do not use pow

ered air

-purifying respirators if airflow is less th

an f

our cfm (115 lpm) f

or tight-

fitting facepieces or six cfm (170 lpm) f

or hoods and / or helmets.

H.  

 Follow established cartridge and canister ch

ange schedules or observe ESLI to ensure th

at 

cartridges and canisters are replaced bef

ore breakthrough occurs.

I.  Contains electrical p

arts th

at may cause an ignition in flammable or explosive atmospheres.

J. F

ailure to properl

y use and maintain this product could result in injury or death.

L.  F

ollow the manufacturer’

s instructions f

or ch

anging cartridges and / or filters.

M. 

 All approved respirators sh

all be selected, fitted, used and maintained in accordance with MSHA, 

OSHA and other applicable regulations.

N. 

 Never substitute

, modify

, add or omit p

arts.  Use onl

y exact replacement p

arts in the configuration 

specified b

y the manufacturer

.

O. 

 Ref

er to User’

s Instructions, and/or maintenance manuals f

or inf

ormation on use and maintenance 

of these respirators.

P.  NIO

SH does not evaluate respirators f

or use as surgical masks.

2

 CA

UTIONS AND LIMIT

ATIONS

HE - High Efficiency P

articulate Air Filter f

or Pow

ered Air Purifying Respirators

 

 

 

 

 

AM 

- Ammonia

 

    

CD - Chlorine dio

xide

 

 

 

 

 

CL 

- Chlorine

 

    

FM 

- F

ormaldehyde

 

    

HC - Hydrogen chloride

 

 

 

 

 

HF - Hydrogen fluoride

  

 

 

 

MA 

- Methy

lamine

 

    

OV

 - 

Organic

 V

apors 

 

 

 

 

SD - Sulfur Dio

xide

 

 

 

 

 

1

 PRO

TECTION

Respi

Ra

to

R Component

s

tC

#

pR

ote

Cti

on

1

aL

te

Rna

te

 H

oo

assem

BL

ies

aLteRnate sUspension / 

HaRD Hat assemBLies

aLteRnate BReatHinG 

tUBes

BLoWeR Unit

poRt pLUG

FiLteR

aLteRnate CaRtRiDGes

aLteRnate CHaRGeR 

assemBLies

BatteRY

aLteRnate BeLts

aCC

esso

Ries

Ca

U

ti

ons

 an

Limit

ati

ons

2

20LFXL

20LFL

20LFm

20LF2L

20LF2m

20LF2s

20tJ

n

20tJ

nt

20ti

Cn

20ti

Cnt

20si

CVn

20si

CVnt

20si

Cn

20si

Cnt

20ti

Csn

20ti

Csnt

20ti

CH

20ti

CHt

20si

CH

20si

CHt

20si

CVH

20si

CHVt

Rt1

Rt1

t

Rt2

Rt2

t

Rt3

Rt3

t

Rt4

Rt4

t

20tG

20Rt

30XXR

30XXp

51XXR

51XXp

pa1B

t

pa1B

tXs

pa1B

tXL

paHB

t

paHB

tXs

paHB

tXL

pa20LFB

t

pa20LFB

tXs

pa20LFB

tXL

pa3

isBU

pa3

pG

pap

RFC1

pap

RFC2

pa3

nBC

pa3

isC

pa3

isGC

pa3

isB

p

pa1

sB

pa1DB

pa1

aFi

pa1

eB

pa1D

eB

20nC

es42

20LCL

RtLC

20sLB

tC

608-150-8118

pap

RpF1

608-150-8114

poLYB

tC

20QCBtC

20LFLeF

20LF2LeF

20LF2me

F

20LF2se

F

21C-0825

H

e

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

aBCF

iJL

mn

ops

23C-2384

oV/CL/HC/HF/

sD/CD/H

e

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

aBCFH

iJL

mn

ops

23C-2306

am

/CL/HC/

ma

/F

m

/HF/

sD/CD/H

e

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

aBCFH

iJL

mn

ops

Содержание PA30IS Series

Страница 1: ... 5 oxygen 2 Do not use when concentrations of contaminants are immediately dangerous to life or health IDLH This term is defined in 29CFR 1910 134 b 3 Do not use these respirators for respiratory protection during abrasive blasting or clean up 4 Do not use in circumstances where the airborne concentration level of contaminant exceeds maximum use concentration for this type of respirator as establi...

Страница 2: ...irflowofapproximatelysevencubicfeetofair perminute 198litersperminute inthehoodundernormaluse Thebatterypack s mountincompartment s onthebackoftheblower Onefullycharged batterypackwillpowertheblowerforapproximatelysevenhours ThePA3ISBUisfittedwithanalarmwhichwillsoundwhenvoltageislow CC20 and RT Series Airline Respirator NIOSH Approval No TC 19C 154 Type C and TC 19C 412 Type C Mostofthesameheadpi...

Страница 3: ... model selected it may be used with either a headband suspension or a hard hat The loose fitting facepiece is constructed of Tychem QC and features an internal suspension All hoods and loose fitting facepieces are approved for use with the PA3ISBU Blower Units Inspect the hood or loose fitting facepiece for any physical damage Mounting the Breathing Tube on the PA3ISBU Blower Ensure that a rubber ...

Страница 4: ...2A1 canister for these gases HE particulate filters are 99 97 effective against all particulate aerosols Filters and cartridges are supplied in quantities of six per box The following abbreviations are approved by NIOSH to indicate the particulates gases or vapors which are removed by the gas vapor cartridges CL Chlorine CD Chlorine Dioxide HC Hydrogen Chloride SD Sulfur Dioxide FM Formaldehyde AM...

Страница 5: ...to the receptacles see Figure 5 until the cartridge is hand tight DO NOT OVER TIGHTEN When using the two PAPRFC1 filter cartridges install the filter plug into one of the ports DO NOT OVER TIGHTEN Figure 6 Donning the Blower and Respirator Prepare to don the blower battery and hood in a safe hazard free area and do the following Check that the cartridges are properly mounted on the blower unit Pri...

Страница 6: ...te on hood see Figure 12 2 Insert the open end of the breathing tube approximately five inches into hood s air entry sleeve see Figure 13 Do not insert breathing tube into hood air entry sleeve more than 6 inches as it may cause a flow restriction 3 Install nylon clamp over air entry sleeve and breathing tube inserting clamp locks through two holes in plastic anchor plate that is sewn into hood Lo...

Страница 7: ...G The user should ensure that the neck cuff is unrestricted all around the neck to allow proper inflation and reduce restrictions Battery run time will be reduced by a restricted or improperly donned hood Loose Fitting Facepiece Use Installing Breathing Tube Assembly in Loose Fitting Facepieces 1 The 20LFM 20LFL 20LFXL 20LF2S 20LF2M and 20LF2L loose fitting facepieces have a sewn in breathing tube...

Страница 8: ...arged to protect the battery and thereby prolong the working life of the unit If the ball in the Airflow Indicator is BELOW or PARTLY BELOW the PASS LINE with a fully charged battery the filter cartridges may need to be changed ĉ Troubleshooting The following guide will enable you to locate and correct malfunctions Malfunction Possible Cause Solution Low Voltage Alarm is sounding but Airflow Indic...

Страница 9: ...alidates all performance statements and approvals for this equipment and could result in death or serious injury Cleaning Once cartridges have reached the end of their useful life discard in accordance with federal state and local guidelines and in conformance with plant safety regulations Use a lint free cloth moistened in a mild solution of soap and warm water to clean the outer surface of the e...

Страница 10: ...for use as surgical masks 2 CAUTIONS AND LIMITATIONS HE High Efficiency Particulate Air Filter for Powered Air Purifying Respirators AM Ammonia CD Chlorine dioxide CL Chlorine FM Formaldehyde HC Hydrogen chloride HF Hydrogen fluoride MA Methylamine OV Organic Vapors SD Sulfur Dioxide 1 PROTECTION Respirator Components TC PROTECTION 1 ALTERNATE HOOD ASSEMBLIES ALTERNATE SUSPENSION HARD HAT ASSEMBLI...

Страница 11: ...eadband suspension 20SICN 20SICNT Tychem SL with taped and sealed seams no headband suspension 20SICVN 20SICVNT Tychem SL with taped and sealed seams and CBRN resistant PVC lens no headband suspension Hoods with Inner Bib and Long Outer Bib for use without a Suspension RT1 RT1T Tychem QC Hood with long inner and outer bib inflatable neck cuff RT2 RT2T TychemSL Hood with long inner and outer bib in...

Страница 12: ...alstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Asia Pacific Bullard Asia Pacific Pte Ltd LHK Building 701 Sims Drive 04 03 Singapore 387383 Tel 65 6745 0556 Fax 65 6745 5176 2013 Bullard All rights reserved Tychem is a registered trademark of E I DuPont de Nemours Company 6081508621F 0915 ISO 9001 certified www bullard com ...

Отзывы: