PA20 Series Powered Air-Purifying Respirator

PA1/PA2 Blower Assembly User Manual

PA1/PA2 - Principle of Operation

The PA20 Powered Air-Purifying Respirator (PAPR) System
is supplied in four parts:

1. The Blower Assembly (Part No. PA1, or Part No. PA2)

which includes:

PA1BU, or PA2BU Blower Unit with Battery
PA1FG Filter/Gasket
PA1SB Belt Assembly
PA1AFI Air Flow Indicator
User Instructions

2. The hood with headband suspension and/or hard hat,

or loose fitting facepiece. The following hood models
may be used with the PA1BU or PA2BU blower unit: (See
listing of hoods for materials and packaging quantities.)

20TJ Hood
20TP Hood with Solvent-Resistant lens
20TIC Hood with Inner Bib
20TPC Hood with Inner Bib and Solvent-Resistant Lens
20TICH Hood for use with Bullard Hard Hat
20TICS Hood with Taped and Sealed Seams
20SIC Hood with Taped and Sealed Seams
20SICH Hood with Taped and Sealed Seams for use
with Bullard Hard Hat
20LFM Loose-Fitting Facepiece Hood, Small-Medium*
20LFL Loose-Fitting Facepiece Hood, Large*

*Uses PA20LFBT Breathing Tube

3. The breathing tube. Choose PA1BT for hoods and

PA20LFBT for loose fitting facepieces

4. The Battery Charger. Both standard and quick chargers

are available.

The high efficiency air-purifying element must be mounted
inside the blower body. The blower unit draws in
contaminated air through the filter. The filtered air is blown
into the wearer’s hood through the breathing tube. A flow
indicator is provided to check that there is an adequate
volume of air available to the wearer prior to use.

The units are designed for use at temperatures from 32º F
to 90º F (0º C to 32º C).

The system is designed to operate at a minimum air flow of
7.5 cubic feet of air per minute (210 liters per minute) in
the hood under normal use. In a heavily contaminated
environment, the battery life may be reduced due to
clogging of the filter.

The PA1BU system (only) is fitted with an audible alarm
which will sound due to low battery power.

NIOSH Approval No. TC-19C-154, Type C

The same headpieces approved for use with the PA20
Series of Powered Air-Purifying Respirators are also
approved for use with the CC20 Series of Supplied Air
Respirators. CC20 Series Respirators provide a high level
of respiratory protection and user comfort over long work
periods, in a wide variety of hazardous environments. 

The CC20 SAR air flow control devices and other
components are described in the CC20/PA20 Series User
Manual.

Principle o

f Oper

a

tion

2

Содержание PA1

Страница 1: ... Use strictly in accordance with instructions labels and limitations pertaining to the PA20 respirator 1 The PA20 respirator does not supply oxygen Use only in adequately ventilated areas containing at least 19 5 oxygen 2 Do not use when concentrations of contaminants are immediately dangerous to life or health 3 Do not use these respirators for respiratory protection during abrasive blasting 4 Do...

Страница 2: ...4 The Battery Charger Both standard and quick chargers are available The high efficiency air purifying element must be mounted inside the blower body The blower unit draws in contaminated air through the filter The filtered air is blown into the wearer s hood through the breathing tube A flow indicator is provided to check that there is an adequate volume of air available to the wearer prior to us...

Страница 3: ...arger follow these important guidelines These guidelines also apply to blower units that have been in storage for extended periods of time For new blower units or blower units that have been in storage for extended periods of time follow the directions above under Battery Pack and when the light begins to flash on the Quick Charger do the following Unplug the charger power cord Wait 15 seconds Plu...

Страница 4: ...ball in the Airflow Indicator should be observed If any part of the ball is below the PASS LINE on the Airflow Indicator check for Clogged or damaged air purifying filter element See Replacing the PA1FG High Efficiency Filter on the next page for filter mounting instructions Low battery charge or battery malfunction Blower malfunction If the ball is completely above the PASS LINE on the Airflow In...

Страница 5: ...the exposed filter pleat Hold the filter only by its edges Check that the filter has a filter gasket and that it is positioned flat behind the filter lip NOTE Always use a new filter gasket when refitting or changing a filter Unclip the blower latches and remove the back cover and belt assembly from the blower unit see Figure 4 Check that the mating faces of blower unit body and the back cover are...

Страница 6: ...e fit as required at this time to ensure a comfortable and stable fit See the CC20 PA20 Series Tychem Hood User Manual PA1BU Low Battery Alarm The PA1BU Blower unit is fitted with a Low Battery Alarm This device will activate if the battery power is below acceptable levels The device is indicating that insufficient airflow is imminent The user should do the following Leave the hazard area remove t...

Страница 7: ...ection and could result in death or serious injury Consult your local safety professional if you suspect that contaminant has entered the breathing tube When cleaning the equipment do the following Ensure water does not enter filter Replace wet filter DO NOT use gasoline organic based solvents or chlorinated degreasing fluids such as trichloroethylene as they will cause damage DO NOT immerse the e...

Страница 8: ...charger for PA2BU Replacement Filter Gasket PA1FG3 Filter gasket assembly 3 per box PA1FGBP Filter gasket assembly 36 per box Replacement Parts and Accessories PA1SB Standard belt PA1DB Decon belt PA1EB Extension belt kit PA1DEB Extension decon belt kit PA1LSK Blower latch and screw kit 4 latches 16 screws PA1AFI Air Flow Indicator PA1BU PA1 Blower housing unit motor and impeller PA2BU PA2 Blower ...

Страница 9: ...cturer s instructions for changing cartridges and or filters M All approved respirators shall be selected fitted used and maintained in accordance with MSHA OSHA and other applicable regulations N Never substitute modify add or omit parts Use only exact replacement parts in the configuration as specified by the manufacturer O Refer to users instructions and or maintenance manuals for information o...

Страница 10: ...285 5273 Tel 859 234 6616 Fax 859 234 8987 www bullard com Bullard GmbH Hochkreuzallee 36 53175 Bonn Bad Godesberg Germany Tel 49 228 931933 0 Fax 49 228 931933 50 2003 Bullard All rights reserved It s Your Life and You re Worth It is a trademark of Bullard Tychem is a registered trademark of E I DuPont de Nemours Company ISO 9001 certified Cert i f i e d I S O 9001 ...

Отзывы: