Model adP3ca Pump Performance table 

incoming drive-air Pressure Maintained at 85 psig

Pump’s output air Pressure 

(psig)

Pump’s output air Volume 

(cfm)*

Maximum Recommended 

Mask Respirators**

Maximum Recommended 

hood Respirators**

Recommended hood 

Respirators with frigitron 

air conditioner

5

24.0

Five

Three

None

10

18.0

Three

Two

None

15

14.0

Two

One

None

18

11.0

Two

One

None

20

8.5

One

One

None

22

7.0

One

None

None

25

4.0

None

None

None

*   Assumes that no air is being dumped from the pressure relief valve and that pump’s drive-air pressure is maintained at 85 psig.
** It should be noted that the minimum air flow required for each tight-fitting, mask-style respirator is four (4) cfm. A minimum airflow of six (6) cfm is required for each 

hood-style respirator.

The ratings which appear here, therefore, are conservative, but reflect Bullard Company’s position that worker respiratory protection is enhanced when air flow available to 

the respirator wearer is above the NIOSH required minimums.

Model adP3ca Pump Performance table 

incoming drive-air Pressure Maintained at 95 psig

Pump’s output air Pressure 

(psig)

Pump’s output air Volume 

(cfm)*

Maximum Recommended 

Mask Respirators**

Maximum Recommended 

hood Respirators**

Recommended hood 

Respirators with frigitron 

air conditioner

5

31.0

Six

Four

None

10

26.5

Five

Three

None

15

21.5

Four

Three

None

18

18.5

Three

Two

None

20

16.5

Three

Two

None

22

14.5

Three

Two

None

25

11.4

Two

One

None

*  Assumes that no air is being dumped from the pressure relief valve and that pump’s drive-air pressure is maintained at 95 psig.
** It should be noted that the minimum air flow required for each tight-fitting mask style respirator is four (4) cfm. A minimum airflow of six (6) cfm is required for each 

hood-style respirator.

The ratings which appear here, therefore, are conservative, but reflect Bullard Company’s position that worker respiratory protection is enhanced when air flow available to 

the respirator wearer is above the NIOSH required minimums.

Содержание Free-Air ADP3CA

Страница 1: ...sured at all times to workers wearing Type C or CE continuous flow airline respirator hoods or tight fitting half or full face masks The ambient air is filtered through a medium efficiency inlet air f...

Страница 2: ...atory protection is enhanced when air flow available to the respirator wearer is above the NIOSH required minimums Model ADP3CA Pump Performance Table Incoming Drive Air Pressure Maintained at 95 psig...

Страница 3: ...e with this pump contact Bullard s customer service department at 877 bullard 3 Airline respirators used withthis pump must not be worn in any atmosphere immediately dangerousto life or health or from...

Страница 4: ...ed to below see the list of pump components to the left Assembling the Free Air Pump 1 Remove assembly from plywood shipping board and attach four rubber feet through four holes in skid 2 Install stan...

Страница 5: ...p is equipped with a 2 ft stand pipe to keep the intake away from the air motor exhaust port If the inlet filter cannot be placed at a source of clean breathable air install Bullard s 50 foot Inlet Ex...

Страница 6: ...ER 1 from the Inlet PIPE 2 If the motor speeds up or the outlet pressure shown on GAUGE 5 increases the filter needs replacement 2 Flush PUMP if necessary Should dirt foreign particles moisture or oil...

Страница 7: ...be defective subject to the following limitations a Free Air Pump must be returned to the Bullard factory with shipping charges prepaid b Free Air Pump must not have been misused subjected to negligen...

Страница 8: ...aterials Bullard may refuse to accept the return of any product suspected of being contaminated 4 Products returned including those under warranty must be shipped with all transportation charges prepa...

Отзывы: