background image

www.bullard.com

ADP3CA Free-Air® Pump

User Manual

Read all instRuctions befoRe using 

this PuMP

table of contents

geneRal infoRMation  ...........................................  1, 2
WaRnings  .............................................................  3
PuMP coMPonents  .................................................  4
bReathing aiR ReQuiReMents  ...............................  4
asseMblY and installation

assembling the free-air Pump  ..........................  4
how air Motor Works  ........................................  4
how Motor drives Pump  ....................................  4
how Pump supplies air  ....................................  4, 5
installation  .....................................................  5

oPeRating the fRee-aiR PuMP  ...............................  5, 6
Maintaining the fRee-aiR PuMP

Maintaining the air Motor  .................................  6
Maintaining the Pump  ......................................  6
ensuring Pump Performance  ..............................  6

tRoubleshooting guide  .......................................  6, 7
RePlaceMent PaRts  ...............................................  7
PuMP WaRRantY  ....................................................  7
aiR filteR RePlaceMent schedule  ........................  7, 8
authoRiZation foR RetuRned goods  ....................  8

general information

Bullard Free-Air Pumps transfer ambient air from a clean air location, where 

breathable air can be assured at all times, to workers wearing Type C or CE 

continuous flow airline respirator hoods or tight fitting half or full face masks.

The ambient air is filtered through a medium efficiency inlet air filter and a carbofine 

outlet filter before entering the respirator’s air supply hose.

Bullard Free-Air Pumps are oil-less and have rotary carbon vanes. They produce no 

carbon monoxide, oil vapors, oil mist or moisture. They do not require expensive 

carbon monoxide monitors, high temperature alarms or airline filters. No calibration 

is required.

note

 

Drive-air pressure (psig) determines horsepower of air motor which 

directly affects output air pressure and output air volume. 

The chart on the next page is where you can find the relevant output air pressure 

(psig) corresponding to the respirator’s approved pressure range to determine the 

pump’s total air volume (cfm) and the maximum number of respirators that can be 

used at that air volume. 

Содержание Free-Air ADP3CA

Страница 1: ...sured at all times to workers wearing Type C or CE continuous flow airline respirator hoods or tight fitting half or full face masks The ambient air is filtered through a medium efficiency inlet air f...

Страница 2: ...atory protection is enhanced when air flow available to the respirator wearer is above the NIOSH required minimums Model ADP3CA Pump Performance Table Incoming Drive Air Pressure Maintained at 95 psig...

Страница 3: ...e with this pump contact Bullard s customer service department at 877 bullard 3 Airline respirators used withthis pump must not be worn in any atmosphere immediately dangerousto life or health or from...

Страница 4: ...ed to below see the list of pump components to the left Assembling the Free Air Pump 1 Remove assembly from plywood shipping board and attach four rubber feet through four holes in skid 2 Install stan...

Страница 5: ...p is equipped with a 2 ft stand pipe to keep the intake away from the air motor exhaust port If the inlet filter cannot be placed at a source of clean breathable air install Bullard s 50 foot Inlet Ex...

Страница 6: ...ER 1 from the Inlet PIPE 2 If the motor speeds up or the outlet pressure shown on GAUGE 5 increases the filter needs replacement 2 Flush PUMP if necessary Should dirt foreign particles moisture or oil...

Страница 7: ...be defective subject to the following limitations a Free Air Pump must be returned to the Bullard factory with shipping charges prepaid b Free Air Pump must not have been misused subjected to negligen...

Страница 8: ...aterials Bullard may refuse to accept the return of any product suspected of being contaminated 4 Products returned including those under warranty must be shipped with all transportation charges prepa...