Страница 1: ... Manual provides detailed instructions warnings and other information for individuals using Bullard Free Air Pump models EDP10 EDP16TE and EDP16HAZA Free Air Pumps Instruction Manual EDP16TE EDP10 EDP16HAZ ...

Страница 2: ... PUMP Model EDP10 5 Model EDP16TE 5 Model EDP16HAZ 5 6 Pump Performance Specifications 6 Electric Motor Specifications 7 OPERATING THE FREE AIR PUMP 8 9 10 11 MAINTAINING THE FREE AIR PUMP 12 FREE AIR PUMP TROUBLE SHOOTING GUIDE 13 14 REPLACEMENT PARTS 15 PUMP WARRANTY 17 AIR FILTER REPLACEMENT SCHEDULE 18 ...

Страница 3: ...e They do not require expensive carbon monoxide monitors high temperature alarms or airline filters No calibration is required The pumps will supply air to one two or three workers depending on the pump model and style of respirator s being used The chart below describes the pump model the number of respirators each unit will supply and its maximum outlet pressure PUMP SPECIFICATION TABLE Maximum ...

Страница 4: ...low pressure continuous flow supplied air respi rators approved by MSHA NIOSH to operate at less than 15 psig 103 kPa Be sure that the pump s outlet pressure measured by the pressure gauge on the pump is maintained above the minimum pressure setting required by the respirator manufacturer To be assured your respirator can be used with this pump refer to a The Pump Specification Table on page 1 for...

Страница 5: ...lure to use approved Bullard components and replacement parts invalidates all Bullard warranties and may result in death or serious injury to the respirator wearer 6 If you have any questions concerning the use of this pump or your respirator or you are not sure the inlet filter is in a breathable location ask your supervisor All instructions for the use and care of this product must be supplied t...

Страница 6: ...ations G 7 1 Grade D or higher as specified by Federal Law 30CFR Part 11 Subpart J 11 121 b The requirements of Grade D breathable air include Oxygen 19 5 23 0 Hydrocarbons condensed in mg m3 of gas 5 mg m3 maximum Carbon Monoxide 10 ppm maximum Carbon Dioxide 1 000 ppm maximum No toxic contaminants at levels which would make the air unsafe to breathe Refer to the C G A Commodity Specification G 7...

Страница 7: ... the pump must be shipped in the future Figure 1 5 b Remove the pressure gauge from its separate box Assemble it to the gauge port located on top of the pump s outlet filter body The gauge should face outward so that it can be read while setting the pressure adjustment knob see Figure 1 3 ALL PUMPS a Unscrew the pump s outlet filter jar and check to be sure the outlet filter cartridge is seated fi...

Страница 8: ... kPa 453 lpm 34 kPa 453 lpm 34 kPa INLET Medium Medium Medium FILTER Efficiency Efficiency Efficiency OUTLET Carbofine Carbofine Carbofine FILTER with activated with activated with activated carbon carbon carbon DIMENSIONS Width 8 inches 20 3 cm 14 inches 35 5 cm 14 inches 35 5 cm Length 16 3 inches 41 4 cm 28 inches 71 1 cm 28 inches 71 1 cm Height 13 5 Inches 34 3 cm 16 inches 40 6 cm 16 inches ...

Страница 9: ... 2 Class III Division 1 2 H P 3 4 1 1 2 1 1 2 PHASE Single Single Three CYCLES 60 Hz 60 Hz 60 Hz VOLTS 115 115 208 230 230 460 Connected for 115 V AMPS 10 2 115 V 16 0 115 V 5 0 230 V 8 0 208 230 V 2 5 460 V SERVICE FACTOR 1 25 1 15 1 0 PROTECTOR Internal Thermal Manual Reset Thermal Thermal Overload and Overload Overload equipped for Starter Contactor to be 115 volt operation provided by the user...

Страница 10: ...om mend using 12 gauge wire Avoid excessive lengths of extension cord especially if running the pump continuously The pump s motor is equipped with manual reset thermal overload protection for 115 volt operation The reset button is located on the side opposite the toggle switch The EDP16TE may be rewired for 208 230 volt 60 Hz operation If rewired to 208 230 a suitable starter contactor and therma...

Страница 11: ...sion Hose Cat V50EX Therefore you may place your inlet filter up to 300 feet 91 4 m 6 x 50 away from the pump Do not add more than 300 91 4 m feet of inlet extension hose to the pump 5 Assemble your respirator by following the manufacturer s directions as described in the respirator s instruction manual Be sure the pump s outlet pressure measured by the pressure gauge on the pump is greater than t...

Страница 12: ...NECTING AIR SUPPLY HOSE S WITHOUT 1 2 QUICK DISCONNECT FITTINGS If your respirator s MSHA NIOSH approved air supply hose will not attach to the pump s standard 1 2 Industrial Interchange outlet coupler see above you can adapt your hose s fitting to the pump by converting the pump s quick disconnect outlet to 3 8 Female NPT with the installation of one of the following adaptors see Figure 6 Cat No ...

Страница 13: ...ssure range by adjusting the pressure adjustment valve located on the outlet filter body To set the pressure adjustment valve loosen the lock nut Once the desired outlet pressure has been obtained retighten the lock nut firmly by hand to maintain consistent outlet pressure see Figure 8 YOU ARE NOW READY TO ENTER THE WORK AREA 11 When finished working leave the work area wearing the respirator with...

Страница 14: ...p in the pump s chamber and rotor slots This will result in decreased outlet pressure or a failure to operate at all If the above occurs the pump should be flushed with the following recommended solvent Loctite Safety Solvent Cat No S17931 12 WARNING NEVER USE KEROSENE OR OTHER COMBUSTIBLE LIQUIDS OR VAPORS WITH THIS PUMP THEIR USE MAY RESULT IN AN EXPLOSION WHICH MAY CAUSE INJURY OR DEATH Directi...

Страница 15: ...oth the inlet filter Cat No 23611 and outlet filter Cat No S17101 are clean and replace if necessary Dirty filters restrict air flow 7 Flush the pump with Loctite Safety Solvent Cat no S17931 to remove excessive dirt sand particles moisture or oil in the rotor assembly See the Maintenance Section on Page 12 of this manual for proper directions on flushing the pump When the parts are reassembled at...

Страница 16: ...supply hose in the bottom of a large container Fill the container with water and ice and cover with a lid For best results locate the container as close to the worker as possible SYMPTOM Outlet Air Temperature Too Cold 1 Let the pump warm up approximately 15 minutes before using 2 Coil the first 25 50 feet 7 6 15 m of air supply hose closest to the pump 3 Keep the air supply hose off cold surfaces...

Страница 17: ...ct Coupler Splitter Adaptor Converts pump s Quick disconnect coupler to DOUBLE 1 2 Industrial Interchange Female Couplers One Flow Through One Shut Off V50IN Remote Inlet Air Hose Kit 50 Feet 15 m 1 per pump V50EX Remote Extension Hose Kit 50 Feet 15 m 5 per pump maximum PARTS FOR 86700 Cat No Description 15921 Service Kit Includes Four Carbon Vanes Inlet Filter Outlet Filter Cartridge 222752 Pump...

Страница 18: ...rtridge EDP 16 TE EDP 16 HAZ S 1710 1 Outlet Filter Cartridge 2448 52 Outlet Filter Jar 2361 1 Inlet Filter S 1710 1 Outlet Filter Cartridge 2448 52 Outlet Filter Jar 2361 1 Inlet Filter S 1968 3 Pressure Gauge S 1968 3 Pressure Gauge S 1648 3 Quick Disconnect Coupler S 1619 1 Quick Disconnect Coupler 1592 1 Service Kit not shown 2635 52 O Ring not shown 1592 1 Service Kit not shown 2635 52 O Ring...

Страница 19: ...r damages for loss of use or other indirect incidental consequential or special costs expenses or damages incurred by the purchaser notwithstanding that E D Bullard Company has been advised of the possibility of such damages ANY IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE 1 YEAR FROM THE DATE OF PURCHASE OF THIS PRO...

Страница 20: ...t 1 615 sq meters Replace the medium efficiency inlet filter Cat No 23611 at least once every 500 running hours or sooner if necessary The inlet filter keeps moisture as well as particulates out of the air supply and helps protect the pump s carbon vanes We recommend the following chart be used to monitor and maintain a routine air filter replacement schedule CARBOFINE OUTLET FILTER MEDIUM EFFICIE...