Understanding Alarms
Low Battery Alarm
The Low Battery Alarm will sound an intermittent electronic beep
indicating that there is approximately fifteen (15) minutes of remaining
battery capacity. The delays between beeps will get shorter and
shorter as time runs out. The battery indicator LED will turn red.
Low Flow Alarm
The Low Flow Alarm will sound a continuous electronic
beep indicating that the flow to the hood has dropped below
the designed specification of 185 L/min (6.5 CFM).
Active Flow Technology
The Active Flow Technology automatically responds to a wearer’s
need for more or less airflow by continually monitoring and adjusting
airflow to keep it constant at the design set point regardless of filter/
cartridge type, hood type, filter loading or battery capacity.
High Temperature
The turbo-blower unit is designed to shut down if operating
temperatures reach 50°C (122°F) and sound an audible alarm.
Technical Specifications
Airflow (low / high speed)
208 / 230 L/min (7.3 CFM / 8.1 CFM)
Sound Pressure Level (SPL)
65 – 67 dBA
(SPL varies by system configuration and filter loading)
Audible Alarms
Low battery, Low airflow, High temperature
Low Battery Alarm
15 minutes remaining
Low Flow Alarm
If activated, do not use PAPR
Operating Temperature
-5°C to 54°C (23°F to 129°F); < 90% RH
Storage Conditions
-5°C to 54°C (23°F to 129°F); < 90% RH
Filter Storage Conditions
0ºC to 32ºC (32ºF to 90ºF); < 90% RH
Turbo-blower unit
IP53: Immersion with Bullard Decontamination and Storage Kit
Battery Charging
4 - 10 hours run time**
4 cells, 6300 mAh, 14.8V Nominal
4-hour charge for empty battery
PAPRFC3
10-year shelf life (unopened in original packaging)
PAPRFC4
5-years shelf life (unopened in original packaging)
PAPRFC5
5-years shelf life (unopened in original packaging)
Belt and Backpack
Chemically resistant closed cell or vinyl/urethane
Adjustable waist sizes 71 cm to 152 cm (28 in to 60 in)
Belt extension available
Hoods*
5-years shelf life (unopened in original packaging)
*All Bullard hoods are latex-free.
**Battery run times depend on hood type, filter/cartridge, selected airflow, and filter loading.
www.bullard.com
11
EVA (with LF-Series and RT-Series Hoods)
Powered Air-Purifying Respirator (PAPR) System