background image

www.bullard.com

9

Or

dering Inf

ormation

20LF Series Respirator Facepiece

User Manual for use with Supplied-Air Respirators

Parts and Accessories

CATALOG
NUMBER DESCRIPTION

FRIGITRON 2000 Series, Cooling, Free Air Pumps  

(Includes 4612 Nylon Belt)

FRIGITRON2000 

 1/2" Industrial Interchange Continuous Flow Control Fitting

FRIGITRON2000B 

 1/2" Industrial Interchange Brass Continuous Flow Control Fitting

FRIGITRON2000S 

 1/2" Industrial Interchange Stainless Steel Continuous Flow 
Control Fitting

HC2400 Series (Metal and Plastic) - Cooling/Heating, Compressed 

Air (Includes 4612 Nylon Belt)

HC240030  1/4" Industrial Interchange Continuous Flow Control Fitting
HC240030B  1/4" Industrial Interchange Brass Continuous Flow Control Fitting
HC240030S   1/4" Industrial Interchange Stainless Steel Continuous Flow Control Fitting
HC240031  1/4" Schrader Continuous Flow Control Fitting
HC240032  1/4" Snap-Tite, Continuous Flow Control Fitting
HC240033  1/4" Snap-Tite Brass, Continuous Flow Control Fitting
HC240034  1/4" Snap-Tite Stainless Steel Continuous Flow Control Fitting
HC240037  1/4" CEJN Continuous Flow Control Fitting
HC240038   1/4" Bayonet Continuous Flow Control Fitting

SAR Air Supply Hoses

V5 Series – Self Coiling Hose, 3/8" ID for Compressed Air, 

Includes QD Coupler and Nipple
XXX denotes color.  RED=Red, BLU=Blue, BLK=Black, YLW=Yellow

V52530XXX  

V5 3/8" ID Starter Industrial Interchange QD Coupling, 25’

V52531XXX  

V5 3/8" ID Starter Schrader QD Coupling, 25’

V52532XXX  

V5 3/8" ID Starter Snap-Tite QD Coupling, 25’

V52533XXX  

V5 3/8" ID Starter Snap-Tite Brass QD Coupling, 25’

V55030XXX  

V5 3/8" ID Starter Industrial Interchange QD Coupling, 50’

V55031XXX  

V5 3/8" ID Starter Schrader QD Coupling, 50’

V55032XXX  

V5 3/8" ID Starter Snap-Tite QD Coupling, 50’

V55033XXX  

V5 3/8" ID Starter Snap-Tite Brass QD Coupling, 50’

V5KF2530XXX  

 V5 Kink Free 3/8" ID Starter Industrial Interchange QD Coupling, 25’

V5KF2531XXX  

V5 Kink Free 3/8" ID Starter Schrader QD Coupling, 25’

V5KF2532XXX  

V5 Kink Free 3/8" ID Starter Snap-Tite QD Coupling, 25’

V5KF2533XXX  

V5 Kink Free 3/8" ID Starter Snap-Tite QD Coupling, 25’

V5KF5030XXX  

 V5 Kink Free 3/8" ID Starter Industrial Interchange QD Coupling, 50’

V5KF5031XXX  

V5 Kink Free 3/8" ID Starter Schrader QD Coupling, 50’

V5KF5032XXX  

V5 Kink Free 3/8" ID Starter Snap-Tite QD Coupling, 50’

V5KF5033XXX  

V5 Kink Free 3/8" ID Starter Snap-Tite Brass QD Coupling, 50’

V10 Series, 3/8" ID for Compressed Air – 
Starter Kit - Includes QD Coupler

4696  

 V10 3/8" ID Starter Industrial Interchange 25’ Black with V13 hose 
to pipe adapter and V17 nipple  

469650    V10 3/8" ID Starter Industrial Interchange 50’ Black with V13 hose 

to pipe adapter and V17 nipple

4696100    V10 3/8" ID Starter Industrial Interchange 100’ Black with V13 

hose to pipe adapter and V17 nipple

46913  

 V10 3/8" ID Starter Schrader 25’ Black with V13 hose to pipe 
adapter, no nipple

46915  

 V10 3/8" ID Starter Snap-Tite 25’ Black with V13 hose to pipe 
adapter, no nipple

46916  

 V10 3/8" ID Starter Snap-Tite 25’ Green, with V13 hose to pipe 
adapter, no nipple

46917  

 V10 3/8" ID Starter Snap-Tite 50’ Green, with V13 hose to pipe 
adapter, no nipple

46918 

 V10 3/8" ID Starter Snap-Tite 25’ Blue with S19443 Nipple

46919  

 V10 3/8" ID Starter Snap-Tite 50’ Blue with S19443 Nipple

SAR Air Supply Hoses

Extension/Custom Assembly – No QD Coupler, Includes V13 hose 

to pipe adapter and V11 hose to hose adapter

5454  

V10 3/8" ID Extension 25’ Black

5457  

V10 3/8" ID Extension 50’ Black      

5458  

V10 3/8" ID Extension 100’ Black      

54514 

V10 3/8" ID Extension 25’ Blue      

54513  

V10 3/8" ID Extension 50’ Blue      

54512  

V10 3/8" ID Extension 100’ Blue      

54510 

V10 3/8" ID Extension 25’ Green      

54511  

V10 3/8" ID Extension 50’ Green      

54515  

V10 3/8" ID Extension 100’ Green

V20 Series, ½" ID for Free Air Pumps – Includes QD Coupler and 

Nipple

V2050ST   V20 1/2" ID Starter Industrial Interchange 50’ Black     
V20100ST  V20 1/2" ID Starter Industrial Interchange 100’ Black

V10 Air Supply Hose Couplers, Nipples and Adapters

V14  

 QD Coupler 1/4" Industrial Interchange, 1/4" Female NPT (V12 
Adapter Separate)

V27  

QD Coupler 1/4" Industrial Interchange with V12 Adapter

V17 

 QD Nipple 1/4" Industrial Interchange, 3/8" Female NPT (V12 
Adapter Separate)

V18 

 QD Coupler 1/4" Schrader, 1/4" Female NPT (V12 Adapter 
Separate)

S19432    QD Nipple 1/4" Schrader, 1/4" Female NPT (V12 Adapter Separate)
V19 

 QD Coupler 1/4" Snap-Tite 1/4" Female NPT (V12 Adapter 
Separate)

V19B  

 QD Coupler 1/4" Snap-Tite 1/4" Female NPT Brass (V12 Adapter 
Separate)

S19442   QD Nipple 1/4" Snap-Tite, 1/4" Female NPT  

(V12 Adapter Separate)

S19443    QD Nipple 1/4" Snap-Tite, 1/4" Female NPT Brass  

(V12 Adapter Separate)

V37  

 QD Coupler 1/4" CEJN 1/4" Female NPT  
(V12 Adapter Separate)

3902  

 QD Nipple 1/4" CEJN 1/4" Female NPT  
(V12 Adapter Separate)

V38  

  QD Coupler 1/4" Bayonet 1/4" Female NPT  
(V12 Adapter Separate)

S19448    QD Nipple 1/4" Bayonet 1/4" Female NPT  

(V12 Adapter Separate)

V11  

Hose Adapter 3/8" to 3/8" Hose Brass

V13  

Hose Adapter 3/8" to 3/8" Pipe Brass

V12  

Hose Adapter 3/8" to 1/4" Pipe Brass

Содержание 20LF Series

Страница 1: ...or stops o Air pressure gauge drops below the minimum specified in the Breathing Air PressureTable WARNING Respirator System Components 2 Respirator Operation 2 Special or Critical User s Instructions 3 Breathing Air Pressure Table 3 Respirator Assembly Component Assembly 4 Donning Doffing 4 Inspection Cleaning and Storage 5 Approval Label 6 7 Parts and Accessories 8 10 Return Authorizations 10 AC...

Страница 2: ...or or pumps manufacturer s instructions for supplying Grade D air including the use of inlet inline filters air dryers carbon monoxide monitors and alarms and periodic testing and maintenance Breathing Air Supply Hoses and Hose Fittings For OSHA compliance only Bullard air supply hoses and fittings approved for use by NIOSH can be used between the breathing tube connection fitting on the wearer s ...

Страница 3: ...Bayonet 27 38 29 40 30 42 31 43 34 49 37 53 40 56 42 60 Cooling Mode AC100030 AC100030B AC100030S Ind Interchange 55 72 57 74 58 75 60 76 62 80 65 83 68 86 70 88 AC100031 Schrader 56 73 58 76 59 77 61 78 63 81 66 84 70 88 72 90 AC100032 AC100033 AC100034 Snap Tite 57 75 59 77 60 78 62 79 64 82 68 86 71 88 72 91 AC100037 CEJN 58 76 60 79 62 80 63 81 65 84 68 87 71 90 73 92 AC100038 Bayonet 60 77 61...

Страница 4: ...reathing tube and flow control using the instructions given on page 4 1 Connect Bullard air supply hose to an air source supplying Grade D breathable air Turn on breathing air source 2 With air flowing connect the facepiece assembly to the air supply hose see Figure 4 Pull back the sleeve on the hose coupler and insert the quick disconnect nipple on the flow control Once the fitting is secured rel...

Страница 5: ...rasive cleaning or solvents may damage the lens or leave harmful residue in the facepiece if improperly rinsed or aired out Breathing Tube Inspection Inspect the breathing tube for tears cracks holes or excessive wear that might reduce the degree of protection originally provided If any signs of excessive wear are present remove the breathing tube from service and discard immediately Inspect the g...

Страница 6: ...d or omit parts Use only exact replacement parts in the configuration specified by the manufacturer O Refer to User s Instructions and or maintenance manuals for information on use and maintenance of these respirators S Special or critical User s Information and or specific use limitations apply Refer to User s Instructions before donning 2 CAUTIONS AND LIMITATIONS CF CONTINUOUS FLOW SA SUPPLIED A...

Страница 7: ...46917 46915 46913 4696 469650 4696100 46916 V2050ST V20100ST V52533XXX V55031XXX V55030XXX V55033XXX V55032XXX V52531XXX V52530XXX V52532XXX V5KF5033XXX V5KF5032XXX V5KF5031XXX V5KF5030XXX V5KF2533XXX V5KF2532XXX V5KF2531XXX V5KF2530XXX V11 V12 V13 V14 V18 V19 V19B V37 V38 V17 S19432 S19442 S19443 3902 S19448 HS HSDC 36501 4612 DC70ML DC70XLXXL DC705X X X X X X X X X X X X X X X X X X X X X X X X ...

Страница 8: ...35B 1 2 Industrial Interchange Brass Continuous Flow Control Fitting Free Air Pumps F35S 1 2 Industrial Interchange Stainless Steel Continuous Flow Control Fitting Free Air Pumps F37 1 4 CEJN Continuous Flow Control Fitting Compressed Air F38 1 4 Bayonet Continuous Flow Control Fitting Compressed Air F40 1 4 Industrial Interchange Adjustable Flow Control Fitting Compressed Air F40B 1 4 Industrial ...

Страница 9: ...ling 50 V10 Series 3 8 ID for Compressed Air Starter Kit Includes QD Coupler 4696 V10 3 8 ID Starter Industrial Interchange 25 Black with V13 hose to pipe adapter and V17 nipple 469650 V10 3 8 ID Starter Industrial Interchange 50 Black with V13 hose to pipe adapter and V17 nipple 4696100 V10 3 8 ID Starter Industrial Interchange 100 Black with V13 hose to pipe adapter and V17 nipple 46913 V10 3 8 ...

Страница 10: ... to Bullard Customer Service will provide you with written permission and a return authorization number as well as the labels you will need to return the product 3 Before returning the product decontaminate and clean it to remove any hazardous materials which may have settled on the product during use Laws and or regulations prohibit the shipment of hazardous or contaminated materials Products sus...

Страница 11: ...o the hose connect the quick disconnect coupler on the air supply hose to the quick disconnectnippleontheAC1000CoolTube 4 Adjust the air pressure at the point of attachment to within the approved pressure range Figure 2 SeetheAirPressureTableonpage3 5 Dontherespiratorbyfollowingthedirectionsinyourrespiratorinstructionmanual 6 Toobtaincoolerair turntheairtemperaturecontrolknobcounterclockwise Figur...

Страница 12: ... while operating the respirator A reliable air pressure gauge must be present to monitor the pressure WARNING Failure to supply the minimum required pressure at the point of attachment for your hose length will reduce airflow and could result in death or serious injury It is important to operate the Bullard climate control device in the prescribed pressure range for the particular Bullard respirat...

Страница 13: ...djust the air pressure at the point of attachment Figure 2 to within the approved pressure range See the Respirator Breathing Air Pressure table in the respirator user manual 5 Putthehoodonbyfollowingthedirec tions in your respirator instruction manual If you do not have instruc tions contact Bullard Customer Service at the address or phone num bers below 6 Turn flow control valve to adjust the fl...

Страница 14: ...st be conducted in an uncontaminated atmosphere Assembling the Cooling Vest 1 Insert the muffler end of the cooling vest connector hose well into the air entry sleeve of the vest Figure 1 For optional use with Bullard Airline Respirators DC50 Series Dual Cool Climate Control Tube and DC70 Vest Instruction Sheet WARNING Failure to supply the minimum required pressure at the point of attachment for ...

Страница 15: ... approved pressure range found in the respirator user manual Figure 4 Operating the Dual Cool Tube 1 To obtain cooler air turn the air temperature control knobs counterclockwise Figure 3 Maximum cooling is obtained when knobs are open completely and when there is maximum airflow out of the Dual Cool tube s exhaust ports To obtain air that is closer to ambient temperature turn air temperature contr...

Страница 16: ...be through the belt bracket 3 With the approved Bullard V20 air supply hose connected to the air source and with air flowing into the hose connect the quick disconnect coupler on the air supply hose to the quick disconnect nipple on the Frigitron 2000 4 Adjust the air pressure at the point of attachment to within the approved pressure range Figure 2 5 Put the hood on by following the directions in...

Страница 17: ...ons 1 Connect the respirator s breathing tube fitting to the female quick disconnect cou pler on the V5 hose 2 Connect the quick disconnect nipple on the hose to the point of attachment on your breathing air source Respirable Breathing Air Respirable breathing air must be supplied to the point of attachment of the approved breathing air supply hose Government regulations require that all breathing...

Страница 18: ...o hose adapter and V13 hose to pipe 3 8 NPT adapter 1 Remove any quick disconnect nipple or adapter from the air source end of the starter hose and replace it with the V11 hose to hose adapter 2 Connect one end of extension hose to the open end of the V11 adapter just inserted in the starter hose 3 If the air source has a threaded attachment use the supplied V13 hose to pipe 3 8 NPT adapter to con...

Страница 19: ...emale quick disconnect cou pler on the V20 hose 2 Connect the quick disconnect nipple on the hose to the point of attachment on your breathing air source Respirable Breathing Air Respirable breathing air must be supplied to the point of attachment of the approved breathing air supply hose Government regulations require that all breathing air meet the specifications for Grade D breathing air as des...

Страница 20: ...nthiana KY 41031 9303 USA Toll free within USA 877 BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Europe Bullard GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Asia Pacific Bullard Asia Pacific Pte Ltd LHK Building 701 Sims Drive 04 03 Singapore 387383 Tel 65 6745 0556 Fax 65 6745 5176 ...