20LF Series airline respirators consist of four components – respirator facepiece, breathing tube, flow control device, and air supply hose. All components must 
be present and properly assembled to constitute a complete NIOSH approved respirator.

CATALOG
NUMBER DESCRIPTION

CATALOG
NUMBER DESCRIPTION

Facepieces & Cover Lenses

Narrow Profile 

20LF2L    20LF Loose Fitting Facepiece 

Tychem® 2000 (QC) Narrow Large 

20LF2LHE   20LF Loose Fitting Facepiece 

Tychem® 2000 (QC) Narrow Large 
Exhaust Filtering 

20LF2M    20LF Loose Fitting Facepiece Tychem® 2000 

(QC) Narrow Medium 

20LF2MHE   20LF Loose Fitting Facepiece Tychem® 2000 (QC) 

Narrow Medium Exhaust Filtering 

20LF2S    20LF Loose Fitting Facepiece Tychem® 2000 (QC) 

Narrow Small 

20LF2SHE   20LF Loose Fitting Facepiece Tychem® 2000 (QC) 

Narrow Small Exhaust Filtering 

Wide Lens 

20LFL 

  20LF Loose Fitting Facepiece Tychem® 2000 (QC) Traditional Large 

20LFLHE    20LF Loose Fitting Facepiece Tychem® 2000 (QC) Traditional Large Exhaust 

Filtering 

20LFM 

 20LF Loose Fitting Facepiece Tychem® 2000 (QC) Traditional Medium 

20LFMHE    20LF Loose Fitting Facepiece Tychem® 2000 (QC) Traditional Medium Exhaust 

Filtering

20LFXL   20LF Loose Fitting Facepiece Tychem® 2000 (QC) Traditional Extra Large 
20LFXLHE   20LF Loose Fitting Facepiece Tychem® 2000 (QC) Traditional Extra Large 

Exhaust Filtering

Lens Covers

20LCL 

 CC20/GR50 Mylar Lens Cover Clear 25 Pack 

20LCLBP   CC20/GR50 Mylar Lens Cover Clear 8 Packs of 25 

Breathing Tube

20LFBT  20LF/20LF2 Breathing Tube, Twist Lock Connection

Standard Flow Controls & Belts (includes QD Nipple to Air 

Supply Hose and 4612 Nylon Belt)

4

612 

Replacement 54" x 1 1/2" Nylon Belt (All Flow Controls)

36501 

 Replacement 54" x 1 1/2" Vinyl Decon Belt (All Flow Controls)

F30 

 1/4" Industrial Interchange Continuous Flow Control Fitting, Compressed Air

F30B 

 1/4" Industrial Interchange Brass Continuous Flow Control Fitting, Compressed 
Air

F30S 

 1/4" Industrial Interchange Stainless Steel Continuous Flow Control Fitting, 
Compressed Air

F31 

 1/4" Schrader Continuous Flow Control Fitting, Compressed Air

F32 

 1/4" Snap-Tite Continuous Flow Control Fitting, Compressed Air 

F33 

 1/4" Snap-Tite Brass, Continuous Flow Control Fitting, Compressed Air

F34 

 1/4" Snap-Tite Stainless Steel Continuous Flow Control Fitting, Compressed Air

F35 

 1/2" Industrial Interchange Continuous Flow Control Fitting, Free Air Pumps

F35B 

 1/2" Industrial Interchange Brass Continuous Flow Control Fitting, Free Air 
Pumps

F35S 

 1/2" Industrial Interchange Stainless Steel Continuous Flow Control Fitting, 
Free Air Pumps

F37 

 1/4" CEJN Continuous Flow Control Fitting, Compressed Air

F38 

 1/4" Bayonet Continuous Flow Control Fitting, Compressed Air

F40 

 1/4" Industrial Interchange Adjustable Flow Control Fitting, Compressed Air

F40B 

 1/4" Industrial Interchange Brass Adjustable Flow Control Fitting, Compressed 

Air

F40S 

 1/4" Industrial Interchange Stainless Steel Adjustable Flow Control Fitting, 
Compressed Air

F41 

 1/4" Schrader Adjustable Flow Control Fitting, Compressed Air

F42 

 1/4" Snap-Tite Adjustable Flow Brass Control Fitting, Compressed Air

F43 

 1/4" Snap-Tite Brass Adjustable Flow Stainless Steel Control Fitting, 
Compressed Air

F44 

 1/4" Snap-Tite Stainless Steel Adjustable Flow Control Fitting, Compressed Air

F47 

 1/4" CEJN Adjustable Flow Control Fitting, Compressed Air

F48 

 1/4" Bayonet Adjustable Flow Control Fitting, Compressed Air

Heating/Cooling Flow Controls & Belts (includes QD Nipple 

to Air Supply Hose and 4612 Nylon Belt)

AC1000 Series – Cooling (Metal & Plastic), Compressed Air Only

AC100030   1/4" Industrial Interchange Continuous Flow Control Fitting
AC100030B   1/4" Industrial Interchange Brass Continuous Flow Control Fitting
AC100030S   1/4" Industrial Interchange Stainless Steel Continuous Flow Control Fitting
AC100031  1/4" Schrader Continuous Flow Control Fitting
AC100032  1/4" Snap-Tite Continuous Flow Control Fitting
AC100033   1/4" Snap-Tite Brass Continuous Flow Control Fitting
AC100034   1/4" Snap-Tite Stainless Steel Continuous Flow 

Control Fitting

AC100037   1/4" CEJN Continuous Flow Control Fitting
AC100038   1/4" Bayonet Continuous Flow Control Fitting

DC5040 Series – Cooling, Use with Cooling Vest, 

Compressed Air Only (Includes 4612 Nylon Belt)

DC5040 

 1/4" Industrial Interchange Continuous Flow Control Fitting

DC5040B   1/4" Industrial Interchange Brass Continuous Flow 

Control Fitting

DC5040S   1/4" Industrial Interchange Stainless Steel 

Continuous Flow Control Fitting

DC5041 

 1/4" Schrader Continuous Flow Control 
Fitting

DC5042 

 1/4" Snap-Tite Continuous Flow Control 
Fitting

DC5043 

 1/4" Snap-Tite Brass,  
Continuous Flow Control Fitting

DC5044 

 1/4" Snap-Tite Stainless Steel Continuous 
Flow Control Fitting

DC5047 

 1/4" CEJN Continuous Flow Control 
Fitting

DC5048 

 1/4" Bayonet Continuous Flow Control 
Fitting

DC70ML 

Cooling Vest DC70 M/L

DC70XLXXL  Cooling Vest DC70 XL/XXL
DC705X 

Cooling Vest DC70 only 5XL

AC1000 Series

20LF Series  

Facepiece

DC5040

Dual-Cool

Frigitron 2000

DC70M/L

DC70XL/XXL

Содержание 20LF Series

Страница 1: ...or stops o Air pressure gauge drops below the minimum specified in the Breathing Air PressureTable WARNING Respirator System Components 2 Respirator Operation 2 Special or Critical User s Instructions 3 Breathing Air Pressure Table 3 Respirator Assembly Component Assembly 4 Donning Doffing 4 Inspection Cleaning and Storage 5 Approval Label 6 7 Parts and Accessories 8 10 Return Authorizations 10 AC...

Страница 2: ...or or pumps manufacturer s instructions for supplying Grade D air including the use of inlet inline filters air dryers carbon monoxide monitors and alarms and periodic testing and maintenance Breathing Air Supply Hoses and Hose Fittings For OSHA compliance only Bullard air supply hoses and fittings approved for use by NIOSH can be used between the breathing tube connection fitting on the wearer s ...

Страница 3: ...Bayonet 27 38 29 40 30 42 31 43 34 49 37 53 40 56 42 60 Cooling Mode AC100030 AC100030B AC100030S Ind Interchange 55 72 57 74 58 75 60 76 62 80 65 83 68 86 70 88 AC100031 Schrader 56 73 58 76 59 77 61 78 63 81 66 84 70 88 72 90 AC100032 AC100033 AC100034 Snap Tite 57 75 59 77 60 78 62 79 64 82 68 86 71 88 72 91 AC100037 CEJN 58 76 60 79 62 80 63 81 65 84 68 87 71 90 73 92 AC100038 Bayonet 60 77 61...

Страница 4: ...reathing tube and flow control using the instructions given on page 4 1 Connect Bullard air supply hose to an air source supplying Grade D breathable air Turn on breathing air source 2 With air flowing connect the facepiece assembly to the air supply hose see Figure 4 Pull back the sleeve on the hose coupler and insert the quick disconnect nipple on the flow control Once the fitting is secured rel...

Страница 5: ...rasive cleaning or solvents may damage the lens or leave harmful residue in the facepiece if improperly rinsed or aired out Breathing Tube Inspection Inspect the breathing tube for tears cracks holes or excessive wear that might reduce the degree of protection originally provided If any signs of excessive wear are present remove the breathing tube from service and discard immediately Inspect the g...

Страница 6: ...d or omit parts Use only exact replacement parts in the configuration specified by the manufacturer O Refer to User s Instructions and or maintenance manuals for information on use and maintenance of these respirators S Special or critical User s Information and or specific use limitations apply Refer to User s Instructions before donning 2 CAUTIONS AND LIMITATIONS CF CONTINUOUS FLOW SA SUPPLIED A...

Страница 7: ...46917 46915 46913 4696 469650 4696100 46916 V2050ST V20100ST V52533XXX V55031XXX V55030XXX V55033XXX V55032XXX V52531XXX V52530XXX V52532XXX V5KF5033XXX V5KF5032XXX V5KF5031XXX V5KF5030XXX V5KF2533XXX V5KF2532XXX V5KF2531XXX V5KF2530XXX V11 V12 V13 V14 V18 V19 V19B V37 V38 V17 S19432 S19442 S19443 3902 S19448 HS HSDC 36501 4612 DC70ML DC70XLXXL DC705X X X X X X X X X X X X X X X X X X X X X X X X ...

Страница 8: ...35B 1 2 Industrial Interchange Brass Continuous Flow Control Fitting Free Air Pumps F35S 1 2 Industrial Interchange Stainless Steel Continuous Flow Control Fitting Free Air Pumps F37 1 4 CEJN Continuous Flow Control Fitting Compressed Air F38 1 4 Bayonet Continuous Flow Control Fitting Compressed Air F40 1 4 Industrial Interchange Adjustable Flow Control Fitting Compressed Air F40B 1 4 Industrial ...

Страница 9: ...ling 50 V10 Series 3 8 ID for Compressed Air Starter Kit Includes QD Coupler 4696 V10 3 8 ID Starter Industrial Interchange 25 Black with V13 hose to pipe adapter and V17 nipple 469650 V10 3 8 ID Starter Industrial Interchange 50 Black with V13 hose to pipe adapter and V17 nipple 4696100 V10 3 8 ID Starter Industrial Interchange 100 Black with V13 hose to pipe adapter and V17 nipple 46913 V10 3 8 ...

Страница 10: ... to Bullard Customer Service will provide you with written permission and a return authorization number as well as the labels you will need to return the product 3 Before returning the product decontaminate and clean it to remove any hazardous materials which may have settled on the product during use Laws and or regulations prohibit the shipment of hazardous or contaminated materials Products sus...

Страница 11: ...o the hose connect the quick disconnect coupler on the air supply hose to the quick disconnectnippleontheAC1000CoolTube 4 Adjust the air pressure at the point of attachment to within the approved pressure range Figure 2 SeetheAirPressureTableonpage3 5 Dontherespiratorbyfollowingthedirectionsinyourrespiratorinstructionmanual 6 Toobtaincoolerair turntheairtemperaturecontrolknobcounterclockwise Figur...

Страница 12: ... while operating the respirator A reliable air pressure gauge must be present to monitor the pressure WARNING Failure to supply the minimum required pressure at the point of attachment for your hose length will reduce airflow and could result in death or serious injury It is important to operate the Bullard climate control device in the prescribed pressure range for the particular Bullard respirat...

Страница 13: ...djust the air pressure at the point of attachment Figure 2 to within the approved pressure range See the Respirator Breathing Air Pressure table in the respirator user manual 5 Putthehoodonbyfollowingthedirec tions in your respirator instruction manual If you do not have instruc tions contact Bullard Customer Service at the address or phone num bers below 6 Turn flow control valve to adjust the fl...

Страница 14: ...st be conducted in an uncontaminated atmosphere Assembling the Cooling Vest 1 Insert the muffler end of the cooling vest connector hose well into the air entry sleeve of the vest Figure 1 For optional use with Bullard Airline Respirators DC50 Series Dual Cool Climate Control Tube and DC70 Vest Instruction Sheet WARNING Failure to supply the minimum required pressure at the point of attachment for ...

Страница 15: ... approved pressure range found in the respirator user manual Figure 4 Operating the Dual Cool Tube 1 To obtain cooler air turn the air temperature control knobs counterclockwise Figure 3 Maximum cooling is obtained when knobs are open completely and when there is maximum airflow out of the Dual Cool tube s exhaust ports To obtain air that is closer to ambient temperature turn air temperature contr...

Страница 16: ...be through the belt bracket 3 With the approved Bullard V20 air supply hose connected to the air source and with air flowing into the hose connect the quick disconnect coupler on the air supply hose to the quick disconnect nipple on the Frigitron 2000 4 Adjust the air pressure at the point of attachment to within the approved pressure range Figure 2 5 Put the hood on by following the directions in...

Страница 17: ...ons 1 Connect the respirator s breathing tube fitting to the female quick disconnect cou pler on the V5 hose 2 Connect the quick disconnect nipple on the hose to the point of attachment on your breathing air source Respirable Breathing Air Respirable breathing air must be supplied to the point of attachment of the approved breathing air supply hose Government regulations require that all breathing...

Страница 18: ...o hose adapter and V13 hose to pipe 3 8 NPT adapter 1 Remove any quick disconnect nipple or adapter from the air source end of the starter hose and replace it with the V11 hose to hose adapter 2 Connect one end of extension hose to the open end of the V11 adapter just inserted in the starter hose 3 If the air source has a threaded attachment use the supplied V13 hose to pipe 3 8 NPT adapter to con...

Страница 19: ...emale quick disconnect cou pler on the V20 hose 2 Connect the quick disconnect nipple on the hose to the point of attachment on your breathing air source Respirable Breathing Air Respirable breathing air must be supplied to the point of attachment of the approved breathing air supply hose Government regulations require that all breathing air meet the specifications for Grade D breathing air as des...

Страница 20: ...nthiana KY 41031 9303 USA Toll free within USA 877 BULLARD 285 5273 Tel 1 859 234 6616 Fax 1 859 234 8987 Europe Bullard GmbH Lilienthalstrasse 12 53424 Remagen Germany Tel 49 2642 999980 Fax 49 2642 9999829 Asia Pacific Bullard Asia Pacific Pte Ltd LHK Building 701 Sims Drive 04 03 Singapore 387383 Tel 65 6745 0556 Fax 65 6745 5176 ...

Отзывы: