8-17
Event Type:
Warning
Event Source:
IANSMiniport
Event Category:
None
Event ID:
22
Description:
Primary Adapter does not sense any Probes:
Intel(R)PRO/1000 ---- Possible reason: partitioned Team.
The above-mentioned event log will appear when the system starts. There is no problem in LAN driver operation.
Problems with Windows
In some cases an event log is registered as follows when you install Windows Server 2003 x64 Editions.
Source: DCOM
Category: Error
Event ID:
10016
Description: The application-specific permission settings do not grant Local Activation permission for the
COM server application with CLSID {555F3418-D99E-4E51-800A-6E89CFD8B1D7} to the
user {NT AUTHORITY\LOCAL SERVICE} SID {S-1-5-19}.
This security permission can be modified using the component Services administrative tool.
→
It is not a problem for system operation.
In some cases an event log is registered as follows when you install Windows Server 2003 x64 Editions.
Event Source: Service Control Manager
Event Type: Error
Event ID:
7011
Description: Timeout (30000 milliseconds) waiting for a transaction response from the IMAP4Svc service.
→
Reboot the system. If this event is not registered again, it is not a problem for system operation.
In some cases an event log is registered as follows when you operate Windows Server 2003 R2.
Source: IPMIDRV
Type: Error
Event ID:
1001
Description: The IPMI device driver attempted to determine if the system supported an IPMI BMC device.
The driver attempted to detect the presence of the IPMI BMC by searching the SMBIOS for
Type 38 record. But either no record was found or the record was not compatible with the
version of the device driver.
If a SMBIOS Type 38 record was detected, the Dump Data field of the event contains a binary
representation of the record.
→
The above event log will be registered if you use "Hardware Management" which is provided by Windows
Server 2003 R2.
Содержание NovaScale T860 E1
Страница 1: ...NovaScale T860 E1 User s Guide NOVASCALE REFERENCE 86 A1 13FA 00...
Страница 2: ......
Страница 16: ...xvi This page is intentionally left blank...
Страница 36: ...2 8 Rear View 1 2 3 4 5 6 7 8 9 10 11 12 13 1 14 12 14 12 14 13 3 13 2 15...
Страница 40: ...2 12 MOTHERBOARD 5 1 2 3 4 6 7 8 9 10 28 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 29 28...
Страница 68: ...3 12 This page is intentionally left blank...
Страница 128: ...4 60 6 Click Home to go back to the WebBIOS Top Menu...
Страница 164: ...5 28 This page is intentionally left blank...
Страница 170: ...6 6 4 Click Parameter File Creator The Parameter File Creator is displayed...
Страница 190: ...7 10 This page is intentionally left blank...
Страница 218: ...8 28 5 Select English The tool menu is displayed Using a local console Using a remote console 6 The tool starts...
Страница 265: ...9 43 7 Remove the two flat countersunk screws from the front of the server chassis...
Страница 309: ...10 1 Chapter 10 Internal Cabling Diagrams Internal cable connections of the server are shown below...
Страница 314: ...10 6 This page is intentionally left blank...
Страница 316: ...A 2 This page is intentionally left blank...
Страница 322: ...C 2 This page is intentionally left blank...
Страница 341: ...D 19 The following screen is displayed 3 Process with the Windows activation according to the following message...
Страница 359: ...E 17...
Страница 363: ...F 2 This page is intentionally left blank...
Страница 369: ......
Страница 370: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 13FA 00...