14
Getting Started With Your System
Maximum shock
Operating
One shock pulse in the positive z axis (one pulse
on each side of the system) of 31 G for 2.6 ms in
the operational orientation
Storage
Six consecutively executed shock pulses in
the positive and negative x, y, and z axes
(one pulse on each side of the system) of 71 G for
up to 2 ms
Six consecutively executed shock pulses in
the positive and negative x, y, and z axes
(one pulse on each side of the system) of 32 G
faired square wave pulse with velocity change at
270 inches/second (686 centimeters/second)
Altitude
Operating
–16 to 3,048 m (–50 to 10,000 ft)
NOTE:
For altitudes above 2950 feet, the
maximum operating temperature is derated
1ºF/550 ft.
Storage
–16 to 10,600 m (–50 to 35,000 ft)
Airborne Contaminant Level
Class
G1 as defined by ISA-S71.04-1985
Environmental
(continued)
Содержание NovaScale R410B F2
Страница 2: ......
Страница 5: ...Getting Started With Your System ...
Страница 19: ...Getting Started With Your System 15 ...
Страница 20: ...16 Getting Started With Your System ...
Страница 21: ...Guide de mise en route ...
Страница 35: ...Guide de mise en route 31 ...
Страница 36: ...32 Guide de mise en route ...
Страница 37: ......
Страница 38: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 X1 46FG 01 ...