background image

48

NovaScale Blade 2320 Installation and User’s Guide

 

Mouse Problems

   

 

The monitor has screen 
jitter, or the screen image 
is wavy, unreadable, 
rolling, or distorted.

If the monitor self-tests show that the monitor is working correctly, consider the 
location of the monitor. Magnetic fields around other devices (such as 
transformers, appliances, fluorescent lights, and other monitors) can cause 
screen jitter or wavy, unreadable, rolling, or distorted screen images. If this 
happens, turn off the monitor. 

Attention:

Moving a color monitor while it is turned on might cause screen 

discoloration.

Move the device and the monitor at least 300 mm (12 in.) apart, and turn on the 
monitor.

NOTE:

To prevent diskette drive read/write errors, make sure that the distance 
between the monitor and diskette drives is at least 75 mm (3 in.). 

If the problem remains, call for service.

Wrong characters appear 
on the screen.

If the wrong language is displayed, update the firmware or operating system with 
the correct language in the blade server that has ownership of the monitor. 

If the problem remains, call for service.

Symptom

Suggested action

Symptom

Suggested action

The mouse does not work.

Make sure that the KVM select button LED on the front of the blade server 
is lit, indicating that the blade server is connected to the shared mouse.

Make sure that the mouse cable is securely connected to the management 
module and that the keyboard and mouse cables are not reversed.

Make sure that the mouse works correctly with other blade servers.

Make sure that the mouse is recognized as a USB device, not PS/2, by the 
blade server. Although the mouse might be a PS/2-style device, 
communication with the mouse is through an internal USB bus in the 
NovaScale Blade Chassis. Some operating systems enable you to select 
the type of mouse during installation of the operating system. Select USB.

If the problem remains, call for service.

Содержание NovaScale Blade 2320

Страница 1: ...NovaScale Blade 2320 Server Installation and User s Guide NOVASCALE BLADE REFERENCE 86 A1 85ER 00...

Страница 2: ......

Страница 3: ...NOVASCALE BLADE NovaScale Blade 2320 Server Installation and User s Guide...

Страница 4: ...ou are invited to use the Ordering Form also provided at the end of this book Trademarks and Acknowledgements We acknowledge the right of proprietors of trademarks mentioned in this book Intel Intel P...

Страница 5: ...System Board Illustration 10 Using System Board Switches 11 Using Light Path Diagnostics to Troubleshoot the System Board 12 Installing Options 15 Installation Guidelines 15 System Reliability Guideli...

Страница 6: ...ages 44 Troubleshooting Charts 46 Memory Problems 46 Microprocessor problems 47 Monitor Problems 47 Mouse Problems 48 Network Connection Problems 49 Option Problems 49 Power Problems 50 Service Proces...

Страница 7: ...67 Warnhinweise f r den Systemzugang 69 Elektrostatische Entladungen ESD 70 Andere Gefahren 71 Fran ais 72 Consignes de s curit sur le serveur 72 S curit avertissements et mises en garde 72 Domaines d...

Страница 8: ...vi NovaScale Blade 2320 Installation and User s Guide...

Страница 9: ...d User s Guide vii List of Tables Table 1 Switch Block 2 SW2 Settings 11 Table 2 System Board LEDs 13 Table 3 Light Path Diagnostics Panel LEDs 13 Table 4 POST Beep Code Descriptions 44 Table 5 Abbrev...

Страница 10: ...viii NovaScale Blade 2320 Installation and User s Guide...

Страница 11: ...Beachten Sie hierzu auch die NovaScale Blade Boards and Chassis Safety Information unter der CD ROM NovaScale Blade Resource CD Consignes de s curit Lisez attentivement toutes les consignes de s curi...

Страница 12: ...an result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this document only at an ESD workstation If o...

Страница 13: ...nstalling the operating system Performing basic troubleshooting of the NovaScale Blade 2320 Server Record information about your NovaScale Blade 2320 Server in the following table Note The model numbe...

Страница 14: ...Statements Used in this Document The following notices and statements are used in this document Note These notices provide important tips guidance or advice Important These notices provide informatio...

Страница 15: ...ly Supports 256 MB 512 MB 1 GB 2 GB and 4 GB 4 DIMM slots Drives Support for two internal small form factor SAS drives Integrated functions Dual Gigabit Ethernet controllers Expansion card interface B...

Страница 16: ...hnology I O expansion The blade server has connectors on the system board for an optional expansion card such as the Fibre Channel expansion card for adding more network communication capabilities to...

Страница 17: ...atic error retry or recovery Automatic server restart Built in monitoring for temperature voltage hard disk drives and flash drives x4 SDDC memory for DIMMs with a capacity of 512 MB or greater Custom...

Страница 18: ...ale Blade Chassis and remove the cover to see the components The following illustration shows the major components of the NovaScale Blade Control Panel Connector Control Panel Cable Heat Sink Micropro...

Страница 19: ...g up the power on LED on the front of the server is lit If a power failure occurs the NovaScale Blade Chassis and then the blade server can start automatically when power is restored if the blade serv...

Страница 20: ...closed normal position in the following illustration To access the power control button you must open the control panel door Keyboard video mouse KVM select button Press this button to associate the s...

Страница 21: ...Press this button to associate the shared removable media drives and USB ports with the blade server The LED on the button flashes while the request is being processed then is lit when the ownership o...

Страница 22: ...n on or turn off the blade server Note The power control button has effect only if local power control is enabled for the blade server Local power control is enabled and disabled through the managemen...

Страница 23: ...lock Switch block SW2 Table 1 Switch Block 2 SW2 Settings Switch number Description SW2 Switch block 2 has eight switches 1 BIOS backup page Off the BIOS starts from the Primary BIOS page On the BIOS...

Страница 24: ...the blade server is removed from the NovaScale Blade Chassis During that period of time you can relight the light path diagnostics LEDs for a maximum of 25 seconds or less depending on the number of...

Страница 25: ...LED Light path diagnostics LED CD111 Light path diagnostics switch SW4 Table 3 Light Path Diagnostics Panel LEDs LED error Action NMI Check error log for additional information Restart the blade serv...

Страница 26: ...ight path diagnostics button SW4 Press SW4 to find faults on the system board If the microprocessor or memory LED is lit reseat the component If the LED remains lit replace the defective component Tab...

Страница 27: ...ts where you can grip the component to remove it from or install it in the blade server or open or close a latch Green on a component or an green label on or near a component indicates that the compon...

Страница 28: ...t Movement can cause static electricity to build up around you Handle the device carefully holding it by its edges or its frame Do not touch solder joints pins or exposed circuitry Do not leave the de...

Страница 29: ...reconfigure the blade server To remove the blade server complete the following steps 1 If the blade server is operating shut down the operating system then press the power control button behind the b...

Страница 30: ...emove it see Removing the NovaScale Blade 2320 Server from a NovaScale Blade Chassis on page 17 for instructions 3 Carefully lay the blade server down on a flat non conductive surface with the cover s...

Страница 31: ...m 0 5 inch 4 Disconnect the control panel cable from the control panel connector 5 Pull the bezel assembly away from the blade server 6 Store the bezel assembly in a safe place Installing a SAS Hard D...

Страница 32: ...ade Chassis on page 17 for instructions 3 Carefully lay the blade server on a flat non conductive surface 4 Open the blade server cover see Opening the NovaScale Blade 2320 Server Cover on page 18 for...

Страница 33: ...line memory modules DIMMs that the blade server supports and other information that you must consider when installing DIMMs The system board contains four DIMM connectors and supports two way memory i...

Страница 34: ...Blade Chassis on page 17 for instructions 4 Carefully lay the blade server on a flat non conductive surface 5 Open the blade server cover see Opening the NovaScale Blade 2320 Server Cover on page 18 f...

Страница 35: ...g notes describe the type of microprocessor that the server supports and other information that you must consider when installing a microprocessor Always install microprocessors that have the same cac...

Страница 36: ...for instructions 6 Locate the microprocessor socket on the system board 7 Remove the two screws that secure the heat sink filler and then remove the filler from the microprocessor socket 8 Install th...

Страница 37: ...system board d Center the microprocessor over the microprocessor socket Align the triangle on the corner of the microprocessor with the triangle on the corner of the socket and carefully press the mi...

Страница 38: ...sink b Align and place the heat sink on top of the microprocessor in the retention bracket grease side down Press firmly on the heat sink c Using a screwdriver secure the heat sink to the retention b...

Страница 39: ...O module bays 3 and 4 must both be compatible with the expansion card All other expansion cards that are installed on other blade servers in the NovaScale Blade Chassis must also be compatible with th...

Страница 40: ...llowing instructions If you replace the original lithium battery with a heavy metal battery or a battery with heavy metal components be aware of the following environmental consideration Batteries and...

Страница 41: ...and installation instructions that come with the battery 3 Turn off the blade server and remove it from the NovaScale Blade Chassis see Installing the NovaScale Blade 2320 Server in a NovaScale Blade...

Страница 42: ...o complete the installation complete the following tasks Instructions for each task are in the following sections 1 Reinstall the blade server bezel assembly if you removed it see Removing the NovaSca...

Страница 43: ...it clicks into place Closing the NovaScale Blade 2320 Server Cover Important The blade server cannot be inserted into the NovaScale Blade Chassis until the cover is installed and closed or an expansio...

Страница 44: ...2 If you have not done so already install any options that you want such as SAS drives or memory in the blade server 3 Select the bay for the blade server Notes a If the blade server has an expansion...

Страница 45: ...ved it Some blade server configuration information and update options are established according to bay number Reinstalling a blade server into a different blade bay from the one from which it was remo...

Страница 46: ...tion buttons on the control panel the media tray select button and the keyboard video mouse select button See Understanding the Control Panel and LEDs on page 8 for information about these buttons and...

Страница 47: ...ver Use it to select the boot protocol and other boot options and to select a power management option For information about using this utility program see Using the PXE Boot Agent Utility Program on p...

Страница 48: ...tion Setup Utility program some of those changes are reflected in the system information you cannot change settings directly in the system information Product Data Select this choice to view the machi...

Страница 49: ...cutive failures to find a boot record You can enable a virus detection test that checks for changes in the boot record when the blade server starts This choice is on the full Configuration Setup menu...

Страница 50: ...n System NMI option on the menu If you enable this option the blade server will automatically restart 60 seconds after the service processor issues a nonmaskable interrupt NMI to the blade server You...

Страница 51: ...o move the switch back to the previous position after the password is overridden See Using System Board Switches on page 11 for the location of switch block 2 Note Shut down the operating system turn...

Страница 52: ...emory and can be attached to e mail alerts Remote graphics console redirection Point to point protocol PPP support Remote power control Remote firmware update and access to critical server settings Ar...

Страница 53: ...server attached to each virtual LAN or subnet With failover you can configure more than one Ethernet controller from each server to attach to the same virtual LAN or subnet Either one of the integrat...

Страница 54: ...SCSI expansion unit in which SCSI hard disk drives are installed Two SAS hard disk drives in the blade server can be used to implement and manage RAID level 0 striping or RAID level 1 mirror arrays F...

Страница 55: ...ge 43 and the NovaScale Blade Hardware Maintenance Manual and Troubleshooting Guide on the CD ROM NovaScale Blade Resource CD for more information Troubleshooting charts The Troubleshooting Charts on...

Страница 56: ...ics in the NovaScale Blade Hardware Maintenance Manual and Troubleshooting Guide on the CD ROM NovaScale Blade Resource CD for more information about POST error messages Table 4 POST Beep Code Descrip...

Страница 57: ...hat the IRQ and I O port assignments that are needed by the serial port are available 1800 PCI adapter hardware interrupt Start the Configuration Setup Utility program and make sure that the interrupt...

Страница 58: ...mory bank might have been manually disabled Check the POST error log for error message 289 If the DIMM was disabled by a system management interrupt SMI replace the DIMM If the DIMMs are not installed...

Страница 59: ...e the NovaScale Blade Chassis Hardware Maintenance Manual and Troubleshooting Guide on the CD ROM NovaScale Blade Resource CD that came with your NovaScale Blade Chassis The screen is blank Make sure...

Страница 60: ...ce Wrong characters appear on the screen If the wrong language is displayed update the firmware or operating system with the correct language in the blade server that has ownership of the monitor If t...

Страница 61: ...ou followed the installation instructions that come with the expansion card The option is installed correctly You have not loosened any other installed options or cables You updated the configuration...

Страница 62: ...blade server is defective or the LED information panel is loose or defective e Local power control for the blade server is enabled use the management module Web interface to verify or the blade server...

Страница 63: ...see Turning off the NovaScale Blade 2320 Server on page 7 and Removing the NovaScale Blade 2320 Server from a NovaScale Blade Chassis on page 17 2 Place the blade server on a flat static protective su...

Страница 64: ...it when the light path diagnostics button is pressed no power is available to light the blade error LEDs and they will be unable to provide any diagnostic information The following table lists the LED...

Страница 65: ...NovaScale Blade Chassis has failed If it has replace the blower Make sure that the room temperature is not too high see NovaScale Blade 2320 Server Specifications on page 3 for temperature information...

Страница 66: ...54 NovaScale Blade 2320 Installation and User s Guide...

Страница 67: ...blade server product when correctly integrated per this guide complies with the following safety and electromagnetic compatibility EMC regulations Intended Application This product was evaluated as I...

Страница 68: ...pe EN55024 Immunity Europe EN61000 3 2 Harmonics Europe EN61000 3 3 Voltage Flicker Europe CE EMC Directive 89 336 EEC Europe VCCI Emissions Japan AS NZS 3548 Emissions Australia New Zealand BSMI CNS1...

Страница 69: ...duct Regulatory Compliance Markings Regulatory Compliance Region Marking cULus Listing Marks USA Canada CE Mark Europe FCC Marking Class A USA EMC Marking Class A Canada VCCI Marking Class A Japan BSM...

Страница 70: ...ill not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is en...

Страница 71: ...of the Canadian Department of Communications Europe CE Declaration of Conformity This product has been tested in accordance to and complies with the Low Voltage Directive 73 23 EEC and EMC Directive 8...

Страница 72: ...e of banned substances in accordance with the European Directive 2002 95 EC Compliance is based on declaration that materials banned in the RoHS Directive are either 1 below all applicable substance t...

Страница 73: ...pecified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s...

Страница 74: ...usceptible to electrical storms we recommend you plug your system into a surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly groun...

Страница 75: ...cord was not provided with your product purchase one that is approved for use in your country Caution To avoid electrical shock or fire check the power cord s that will be used with the product as fo...

Страница 76: ...tem without the fan guard in place Rack Mount Warnings The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended from it Th...

Страница 77: ...n Carefully route cables as directed to minimize airflow blockage and cooling problems For proper cooling and airflow operate the system only with the chassis covers installed Operating the system wit...

Страница 78: ...derer Produkte oder Komponenten f hrt zum Erl schen der UL Zulassung und anderer Genehmigungen f r das Produkt Dadurch kann das Produkt gegen Produktbestimmungen versto en die im Verkaufsland gelten S...

Страница 79: ...der Ersch tterungsquellen Abgeschirmt von starken elektromagnetischen Feldern die durch elektrische Ger te erzeugt werden In gewittergef hrdeten Gebieten sollten Sie das System an einen berspannungssc...

Страница 80: ...t werden k nnen ffnen Sie das Netzteil nicht Im Netzteil bestehen gef hrliche Spannungen Str me und Energiequellen Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Wenn Sie ein hot...

Страница 81: ...gungselementen F hren Sie keine Arbeiten im Netzteil aus Das Netzteil enth lt keine f r den Benutzer wartungsbed rftigen Teile Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Scha...

Страница 82: ...in eingebauten Ger te ordnungsgem geerdet sein Elektrostatische Entladungen ESD Vorsicht Elektrostatische Entladungen k nnen zur Besch digung von Festplatten Platinen und anderen Komponenten f hren Da...

Страница 83: ...ystem nur mit angebrachten Geh useabdeckungen betrieben werden Die Inbetriebnahme des Systems ohne Abdeckung kann zur Besch digung von Systemkomponenten f hren So bringen Sie die Abdeckung wieder an V...

Страница 84: ...ns r glementaires du produit et le produit peut ne pas tre conforme aux autres lois et r glementations locales applicables au produit S curit avertissements et mises en garde Pour viter de vous blesse...

Страница 85: ...es de chaleur telles que la lumi re directe du soleil et les radiateurs l cart des sources de vibration ou des chocs physiques Isol des champs lectromagn tiques importants produits par des appareils l...

Страница 86: ...me Lorsque vous remplacez un bloc d alimentation chaud d branchez le cordon du bloc d alimentation en cours de remplacement avant de le retirer du serveur Pour viter tout risque d lectrocution mettez...

Страница 87: ...d alimentation Il ne contient aucune pi ce r parable Renvoyez le au fabricant en cas de probl me Mettez le serveur hors tension et d branchez tous les cordons d alimentation avant d ajouter ou de remp...

Страница 88: ...ck doivent tre correctement reli s la terre D charges lectrostatiques ESD Attention Les d charges lectrostatiques ESD peuvent endommager les lecteurs de disque dur les cartes et d autres pi ces Il est...

Страница 89: ...s de refroidissement Afin de permettre une ventilation et un refroidissement corrects ne mettez le syst me en marche que lorsque les panneaux du ch ssis sont en place L utilisation du syst me sans les...

Страница 90: ...a homologaci n UL y otras certificaciones oficiales del producto pudiendo dejar de ser compatible con las normativas locales de los pa ses en los que se comercializa Advertencias y precauciones sobre...

Страница 91: ...ntilada y alejada de fuentes de calor incluida la luz solar directa y los radiadores Alejada de fuentes de vibraci n o de golpes f sicos Aislada de campos electromagn ticos producidos por dispositivos...

Страница 92: ...n Dentro de la fuente de alimentaci n puede haber niveles de tensi n corriente y energ a peligrosos Devu lvala al fabricante para repararla Al reemplazar una fuente de alimentaci n de conexi n en func...

Страница 93: ...e acceso No acceda al interior de la fuente de alimentaci n No hay elementos en la fuente de alimentaci n que usted pueda reparar y utilizar Devu lvala al fabricante para repararla Apague el servidor...

Страница 94: ...una conexi n a tierra apropiada para el rack y para cada pieza del equipo instalada en el mismo Descarga electrost tica ESD Precauci n Las descargas electrost ticas pueden da ar las unidades de disco...

Страница 95: ...y de refrigeraci n Para conseguir una refrigeraci n y corriente de aire adecuadas compruebe que cuando sistema est funcionando las cubiertas de la carcasa est n instaladas Si utiliza el sistema sin l...

Страница 96: ...84 NovaScale Blade 2320 Installation and User s Guide...

Страница 97: ...NovaScale Blade 2320 Installation and User s Guide 85 C Getting Help Contact your Bull Support representative You may also find some information on the Bull Support website http support bull com...

Страница 98: ...86 NovaScale Blade 2320 Installation and User s Guide...

Страница 99: ...the equipment and shall be easily accessible SAFETY STEPS Whenever you remove the chassis covers to access the inside of the system follow these steps 1 Turn off all peripheral devices connected to t...

Страница 100: ...parts Contact should be made with care Consider wearing protective gloves Danger of explosion if the battery is incorrectly replaced Replace only with the same or equivalent type recommended by the eq...

Страница 101: ...des Wechselstrom Netzkabel aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das Systeminnere...

Страница 102: ...die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Komponenten au...

Страница 103: ...etzt sein keine starken von elektrischen Ger ten erzeugten elektromagnetischen Felder aufweisen in Regionen in denen elektrische St rme auftreten mit einem berspannungsschutzger t verbunden sein w hre...

Страница 104: ...der l int rieur du syst me suivez les consignes suivantes 1 Mettez hors tension tous les p riph riques connect s au syst me 2 Mettez le syst me hors tension en mettant l interrupteur g n ral en posit...

Страница 105: ...n aux broches aigu s des cartes et aux bords tranchants du capot Nous vous recommandons l usage de gants de protection Danger d explosion si la batterie n est pas remont e correctement Remplacer uniqu...

Страница 106: ...a la tapa del chasis para acceder al interior del sistema siga las siguientes instrucciones 1 Apague todos los dispositivos perif ricos conectados al sistema 2 Apague el sistema presionando el interru...

Страница 107: ...tener en cuenta que en el chasis o en el tablero puede haber piezas cortantes o punzantes Por ello se recomienda precauci n y el uso de guantes protectores Existe peligro de explosi n si la pila no se...

Страница 108: ...edere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore del siste...

Страница 109: ...ldati Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio consigliabile l uso di guanti di protezione Esiste il pericolo di un esplosione se la pila non vien...

Страница 110: ...98 NovaScale Blade 2320 Installation and User s Guide...

Страница 111: ...TION Your comments will be promptly investigated by qualified technical personnel and action will be taken as required If you require a written reply please include your complete mailing address below...

Страница 112: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 113: ......

Страница 114: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE 86 A1 85ER 00 REFERENCE...

Отзывы: