INSTALLATION INSTRUCTIONS
Your
power burner comes to you fully assembled. We strongly recommend professional installation and hookup of the gas power burner. These
instructions will provide you with the measurements necessary for you or your builder to construct a masonry structure to house your outdoor gas
power burner.
NOTE TO INSTALLER:
Leave these instructions with the consumer for future reference
.
The power burner must be installed in accordance with all
local building codes.
SPECIFICATIONS FOR POWER BURNER STRUCTURE
1. Your choice of masonry can be used for cabinet construction for the power burner; however it must be
non-combustible
material. Keep in mind
when choosing a location for your power burner that it should NOT be located under any overhead combustible construction.
2. The power burner requires a wall opening of the following dimensions:
See PAGES 6 & 7 for different models.
3. Place power burner assembly into wall opening as shown in illustration on pages 6 & 7.
4.
For propane gas LP TANK STORAGE AREA MUST BE ISOLATED FROM POWER BURNER AND VENTED.
5. Do not use any combustible materials for this construction. Minimum horizontal clearance to adjacent combustible surface from side and back of
the power burner must be
21 inches
.
CONNECTING TO GAS SOURCE
Refer to the following instructions and illustrations for typical gas supply connections. We strongly suggest professional installation
and
hook-up of
the power burner.
IMPORTANT:
Before connecting power burner to gas source, make sure power burner control knobs are in “OFF” position.
5
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING YOUR POWER BURNER
NATURAL GAS CONNECTIONS
IMPORTANT:
Bull Outdoor Products does not recommend the use of any quick connect
fittings or lines to the unit. Use of these types of fittings or lines could cause low gas flow
and greatly reduce the performance of the unit.
- Pipe sealing compound or pipe thread tape of the type resistant to the
action of natural gas must be used on all male pipe thread.
- Apply compound or tape to at least the first three threads when making the connection.
- Remove plastic or rubber cap from regulator installed on power burner.
- Attach stainless steel flex line 3/8” flare-female end to the regulator.
- Attached the other end of flex line to shut-off valve through a nipple.
- Attach a shut-off valve to gas supply pipe.
PERFORM GAS LEAK CHECK – REFER TO PAGE 2
PROPANE GAS CONNECTIONS
- In the United States, the LP
gas pressure regulator and hose assembly supplied with this
unit must be used without alteration. If this assembly needs to be replaced, use only the
type 1 specified in the parts list supplied with this unit. Use a LP tank with a type 1 cylinder
valve.
- Make sure the tank is firmly secured in an upright position.
- Turn the black coupling nut of the hose and regulator assembly in a clockwise direction.
- Make sure it is completely threaded onto the cylinder valve before turning gas supply on.
PERFORM GAS LEAK CHECK – REFER TO PAGE 2
Содержание 96000
Страница 17: ...EXPLODED ILLUSTRATION 16...