TROUBLESHOOTING
IF SINGLE SIDEBURNER FAILS TO OPERATE PROPERLY
1. Turn off gas at source, turn control knob to “OFF”, and wait five minutes before trying again.
2. Check gas supply/connections.
3. Repeat lighting procedure.
If single sideburner still fails to operate properly,
TURN “OFF” GAS AT SOURCE, TURN CONTROL KNOB TO “OFF”
, wait for sideburner to
cool, and check the following:
a.
Misalignment of burner tube over ventri tube
CORRECTION:
Reposition burner tube to properly seat inside ventri tube.
b.
Obstruction in gas line
CORRECTION:
Remove fuel line from the single sideburner. DO NOT SMOKE AROUND EXPOSED GAS LINE! Open gas supply for one second
to blow any obstruction from fuel line. Close off gas supply at source and reconnect fuel line to the sideburner.
c.
Plugged orifice
CORRECTION:
Remove the valve from the ventri tube and gently clear any obstruction in the orifice with a fine wire. Re-install the valve into the
ventri tube. If an obstruction is suspected in the gas valve or the ventri tube, please contact your single sideburner dealer or gas appliance service
person for assistance.
d.
Misalignment of igniter on burner
CORRECTION:
Check for proper position of igniter tip. The tip of the igniter should be relatively close to the burner ports and free from grease for
spark discharging. The ignition wire should be firmly connected to the valve ignition and igniter. Replace the ignition wire if the wire were broken or
cracked. With gas supply closed and the control knob set to “OFF”, check the positive igniter individually for presence of spark at igniter tip. Push
the control knob in fully and rotate about 1/4 turn to the left (counter-clockwise) until click is heard; the trigger hitting the strike block should produce
a blue spark at the igniter tip. Return control knob to “OFF”.
If re-ignition is necessary
While the single sideburner is still hot, you must wait for a minimum of five minutes before commencing to re-ignite (this allows accumulated gas
fumes to clear). If all checks/corrections have been made and the single sideburner still fails to operate properly, consult your sideburner dealer or
gas appliance service person.
FLASHBACK
When fire occurs in and around the burner tube, immediately turn off gas at its source and turn the control knob to “OFF”. Wait until the single
sideburner has cooled completely, then clean the burner tube as described on page 8.