153
6 Command Line Interface Management
Your NovaScale Blade 1 GB Intel® Ethernet Switch Module supports a management interface that
you can use to set up and control your device over the network using the TCP/IP Telnet protocol.
You can use this facility to perform the same network management functions that you can perform
using the Web Interface. You can also use the Telnet interface to configure the switch module for
management using an SNMP-based network management system. This chapter describes how to use
the CLI to access the NovaScale Blade 1GB Intel® Ethernet Switch Module, change its settings, and
monitor its operation.
Important:
Before you configure your NovaScale Blade 1GB Intel® Ethernet Switch Module, be
sure that the management modules in your NovaScale Blade Chassis unit are properly configured. In
addition, to access and manage your switch module from an external environment, you might need
to enable certain features, such as the external ports and external management over all ports. See the
applicable
Installation and User’s Guide
publications on the
NovaScale Blade Chassis Resource
CD
for more information.
Command Line Interface (CLI) conventions
The Command Line Interface (CLI) syntax, conventions and terminology are described in this
section. Each CLI command referenced in this document is illustrated using the structure outlined
below.
Format
Some commands, such as
show inventory
, do not require parameters. Other commands, such as
config lag deleteport
, have parameters for which you must supply a value. Parameters are
positional — you must type the values in the correct order. Optional parameters will follow required
parameters. For example:
config vlan mcaststorm
<1-4094> <enable/disable> [packets per second]
•
config vlan mcaststorm
is the command name.
•
<1-4094> <enable/disable>
are the required values for the command.
•
[packets per second]
is the optional value for the command.
config lag deleteport
<logical port> <port/listofports/all>
•
config lag deleteport
is the command name.
•
<logical port>
<port/listofports/all>
are the required values for the command. Please note that
usually the actual value of the parameter as seen in the CLI, e.g.
<1-4094>
, is used in the
documentation. In some instances a generic term(s) such as
<port/listofports/all>
must be used
since listing all possible choices is not possible.
Содержание 1GB Intel Ethernet Switch Module
Страница 1: ...1GB Intel Ethernet Switch Module Installation and User Guide NOVASCALE BLADE REFERENCE 86 A1 23ER 00 ...
Страница 2: ......
Страница 26: ...xxiv NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Страница 42: ...16 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Страница 177: ...Web Based Network Management 151 ...
Страница 178: ...152 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Страница 254: ...228 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Страница 256: ...230 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Страница 258: ...232 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Страница 266: ...240 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Страница 276: ...250 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Страница 295: ...Understanding and Troubleshooting the Spanning Tree Protocol 269 ...
Страница 304: ...278 NovaScale Blade 1 GB Intel Ethernet Switch Module Installation and User s Guide ...
Страница 307: ......
Страница 308: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE 86 A1 23ER 00 REFERENCE ...