Chapter 3. NovaScale Master Server Add-ons Description
17
Notes:
•
This category is based on the GAMTT management product from LSI. This tool and
especially its SNMP interface is a requirement for the following GAMTTraid
monitoring services. Check that this tool works on the targeted OS, if you want to
monitor with it in NOVASCALE Master.
•
This category is based on GAMTT management product from LSI. The previous
(NOVASCALE Master release 4.0) ” MegaRAID” category is based on
PowerConsolePlus management product from LSI. These two management products are
functionally redundant but not compatible. So you need to replace the ”MegaRAID”
category and its services by ”GAMTTraid” category and services, if you replace
PowerConsolePlus by GAMTT.
3.1.1.2
GAMTTraid Category
Status
For NovaScale and Express5800 hosts with an LSI (or Mylex) SCSI
RAID card managed by GAMTT (or GAM) management tool. This
service checks the Host RAID status reported by the associated GAMTT
SNMP agent.
Alerts
For NovaScale and Express5800 hosts. When an alert is sent from the
GAMTT SNMP agent, it is processed by the NovaScale Master server.
Note:
The mlxraid.mib mib is integrated in the NovaScale Master
application.
Note:
Do not forget to configure the agent to send SNMP traps to the NovaScale Master server by
adding the NovaScale Master server host address to the SNMP managers list of this agent.
3.1.1.3
check_gamttRAID (any OS) Nagios command
The configurable NovaScale Master service check command syntax is:
check_gamttRAID!<community>!<port>!<timeout>!{ [-A {ALL|<Ct>}] |
[-P {ALL|<Ct>.<Ch>.<Tg>}] | [-L {ALL|<Ct>.<Ldn>}] }
Input
<community>
SNMP community string (defaults to ”public”)
<port>
SNMP port (defaults to 161)
<timeout>
Seconds before timing out (defaults to Nagios timeout value)
-A, --adapter ALL | <Ct>
Controller board
-P, --physical ALL | <Ct>.<Ch>.<Tg> Physical device addr
-L, --logical ALL | <Ct>.<Ldn>
Logical drive addr
Содержание NovaScale Master 5.1
Страница 2: ......
Страница 14: ...4 NovaScale Master 5 1 Server Add ons Installation and Administrator s Guide...
Страница 55: ...Chapter 3 NovaScale Master Server Add ons Description 45 Figure 3 21 Virtual Platform monitoring...
Страница 64: ...54 NovaScale Master 5 1 Server Add ons Installation and Administrator s Guide Figure 3 31 jonasAdmin launching...
Страница 88: ...78 NovaScale Master 5 1 Server Add ons Installation and Administrator s Guide...
Страница 91: ......
Страница 92: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A2 95ER 02...