GAS 222.31 Ex2
CAUTION
Drive pressurised
Never loosen or remove the cover or any accessories with the drive pressurised.
CAUTION
Never open the drive with the function “single-acting”!
This may only be done at the manufacturer’s plant.
CAUTION
Do not attach levers or tools to the drive’s spindle!
Levers and tools on the spindle can flap around when switching the compressed air or
control voltage back on and cause serious injury or damage!
6.1 Maintaining the filter element
The probes feature a particle filter which needs to be changed as it becomes dirty.
To do so, disconnect the voltage supply and if applicable close the shut-off valve to the process or switch off the process.
CAUTION! Do not damage the rear filter seat.
NOTICE
Ceramic filter elements
are very brittle by nature. Handle them with care, don’t let them
fall.
Filter elements made out of sintered stainless steel
can be cleaned in an ultrasonic bath
and be used several times as long as both seals are still in proper conditions.
6.1.1 Replacing the Inlet Filter
The probes are equipped with an inlet filter which is always inside the process stream. The filter is suitable for (Inert gas) blow-
back with compressed air, i.e. blowing air (Inert gas) through the filter from the inside to the outside to remove adhering
particles. When sampling flammable gases, nitrogen (inert gas) must be used for blowback. Blowback of explosive gases is pro-
hibited.
The effectiveness of cleaning a filter within a process is directly influenced by the available airflow (amount of gas). We there-
fore recommend using a pressure vessel directly on the probe.
With sufficient inlet filter blowback (within the process stream) the probes are maintenance-free. However, due to process con-
ditions the filter may clog over time. In this case the filter element will need to be replaced.
To do so, the probe must be completely removed and reinstalled after changing the element.
Condensate inside the pressure vessel
Depending on the installation site and application conditions a small amount of condensate may form inside the blowback air
pressure vessel. Open the drain screw at the bottom of the vessel and drain the condensate at least once a year.
If the probe needs to be serviced more frequently due to operating conditions, we recommend also draining the condensate at
these intervals.
CAUTION
High pressure
Pressure vessel under pressure.
Before opening the condensate drain, close the air supply to the blowback control and
drain the vessel by manual blowback.
Pressing the main switch for the blowback control to interrupt the voltage supply.
16
Bühler Technologies GmbH
BE460052 ◦ 08/2019
Содержание GAS 222.31 Ex2
Страница 26: ...GAS 222 31 Ex2 9 6 Dimensions 24 B hler Technologies GmbH BE460052 08 2019...
Страница 27: ...GAS 222 31 Ex2 25 B hler Technologies GmbH BE460052 08 2019...
Страница 34: ......
Страница 35: ......
Страница 36: ......
Страница 37: ......
Страница 38: ......
Страница 47: ...DE 461099 05 2016 Page 8 9...