BCM-MS, BCM-LS
8.2 BCM-MS Technical Data
BCM-MS200–1DC2A
1DC2A
Dimensions
Version:
Compact unit
Type Plate
Gasket
Process connection:
G3/4
Material in contact with media:
aluminium, HNBR, polyurethane resin,
epoxy resin, electroless nickel immersion
gold (ENIG), solder, aluminium oxide, glass,
gold, silver palladium
Medium temperature:
-20 °C to +85 °C
Ambient temperature:
-20 °C to +85 °C
Pressure resistance:
50 bar
Compatible fluids:
mineral oils (H, HL, HLP, HLPD, HVLP), syn-
thetic esters (HETG, HEPG, HEES, HEPR),
polyalkylene glycol (PAG), zinc- and ash-free
oils (ZAF), poly-alpha-olefins (PAO)
Weight:
140 g
Operating voltage (U
B
):
9 – 33 V DC
Power input:
max. 0.2 A
Measuring range
Temperature:
-20 °C…85 °C
Rel. humidity:
0…100 %
Rel. permittivity:
1…7
Conductivity:
100…800,000 pS/m
Measuring accuracy
Temperature:
±2 K
Rel. humidity:
±3 %
Rel. permittivity:
±0.015
Conductivity (100…2,000 pS/m):
±200 pS/m
Conductivity (2,000…800,000 pS/m): <±10 %
1DC output:
RS232/CANopen/SAE J1939
2A output:
2x 4-20 mA (assigned to one fixed measur-
and or sequential output of all values)
43
Bühler Technologies GmbH
BE150104 ◦ 03/2021